background image

                         NEC 

Solutions 

(America), 

Inc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Visual Systems 

LT260/260K Installation Guide 

Desktop and Ceiling Mount

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

v3.5

 

 

Contents 

Product Description, Lens Specs, Notes and Formulas 

 

 

Page 1 

Projection Distances and Screen Sizes 
   Ceiling 

Mount 

Installation 

        Page 2 

Desktop Setup 

 

 

 

 

 

 

 

 

 

 

Page 3 

Cabinet Dimensions 
   Top, 

Front 

and 

Right 

Side        Page 4 

   Bottom, 

Back 

and 

Left 

Side 

       Page 5 

Ceiling 

Mount 

Dimensions           Page 6 

Control Codes  

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 7 

 

Product 

Description     

                                               

Type: 

    1 

chip 

DLP

TM

 

projector     Dimensions: 

10.24”(W) 

4.74”(H) 

11.81”(D) 

 

Native 

Resolution: 1024 

768 

(XGA)      Weight:  6.5 

lbs 

Brightness:   LT260: 

 2100 

ANSI 

      LT260K: 

2400 

ANSI 

 

Lens Specifications                                                        

 

Throw 

Ratio: 

  2.0 

2.4:1(approx.)      Focal 

Length: 

28.4mm 

– 

34.0mm 

Offset 

Angle: 

  12.3

 °

-14.9

 ° 

(approx.) 

     F/#:   2.2 

– 

2.5 

Screen 

Sizes: 

  30”-500” 

        Manual 

Focus/Manual 

Zoom 

 

Notes

                                                                     

 

For screen sizes not indicated on the projection charts, use the formulas below. 

 

If a value in a chart does not match the results of the formulas, use the values in the chart. 

 

The ceiling must be strong enough to support the projector and the installation must be in accordance with any local 
building codes. 

 

All formulas are based on a 4:3 aspect ratio and screen. 

 

4:3 sources can be displayed on a 16:9 screen without vertical “squeezing”, see “Aspect Ratio” in the user manual. 

 

Distances are in inches, for millimeters multiply by 25.4. 

• 

Distances may vary 

±

5%. 

 

Formulas                                                        

         

Units: Inches 

(for millimeters multiply final number by 25.4)

 

 

Projection Formulas:   

 

 

 

 

 

 

Definitions: 

B

 

0.5265H 

– 

0.013 

        

H

 = Horizontal Screen Width (4:3) 

C

 (wide) = 2.0062H – 1.764   

 

 

 

 

 

V

 = Vertical Screen Height (4:3) 

C

 (tele)  = 2.4281H – 1.260   

 

 

 

 

 

B

 = Vertical distance between lens center and screen center 

D

 

0.1515H 

0.013 

        

C

 = Throw distance 

α

 (wide) = tan

-1

 (B/C(wide))   

 

 

 

 

 

D

 = Vertical distance between lens center and screen top 

α

 (tele)   = tan

-1

 

(B/C(tele))         

(screen 

bottom 

for 

desktop 

application) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

α

 = Throw Angle 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen Formulas (4:3):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 = Screen Diagonal x 4/5 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 = Screen Diagonal x 3/5 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen Diagonal

 = H x 5/4 

 
 
 

www.necvisualsystems.com 

 

LT260/260K 

Page 1 of 7 

Summary of Contents for LT260 Series

Page 1: ... does not match the results of the formulas use the values in the chart The ceiling must be strong enough to support the projector and the installation must be in accordance with any local building codes All formulas are based on a 4 3 aspect ratio and screen 4 3 sources can be displayed on a 16 9 screen without vertical squeezing see Aspect Ratio in the user manual Distances are in inches for mil...

Page 2: ...9 12 3 72 57 6 43 2 30 3 113 8 138 6 8 7 14 9 12 3 84 67 2 50 4 35 4 133 1 161 9 10 2 14 9 12 3 90 72 54 37 9 142 7 173 6 10 9 14 9 12 3 100 80 60 42 1 158 7 193 0 12 1 14 9 12 3 120 96 72 50 5 190 8 231 8 14 5 14 8 12 3 150 120 90 63 2 239 0 290 1 18 2 14 8 12 3 180 144 108 75 8 287 1 348 4 21 8 14 8 12 3 210 168 126 88 4 335 3 406 7 25 4 14 8 12 3 240 192 144 101 1 383 4 464 9 29 1 14 8 12 3 270...

Page 3: ...4 67 2 50 4 35 4 133 1 161 9 10 2 14 9 12 3 90 72 54 37 9 142 7 173 6 10 9 14 9 12 3 100 80 60 42 1 158 7 193 0 12 1 14 9 12 3 120 96 72 50 5 190 8 231 8 14 5 14 8 12 3 150 120 90 63 2 239 0 290 1 18 2 14 8 12 3 180 144 108 75 8 287 1 348 4 21 8 14 8 12 3 210 168 126 88 4 335 3 406 7 25 4 14 8 12 3 240 192 144 101 1 383 4 464 9 29 1 14 8 12 3 270 216 162 113 7 431 6 523 2 32 7 14 8 12 3 300 240 18...

Page 4: ...mensions for the LT260 Dimensions are in inches For millimeters multiply by 25 4 O O 2 756 3 169 3 268 4 213 4 724 4 094 3 622 11 811 10 827 10 236 2 244 2 5 2 0 2 894 3 268 1 398 2 303 7 362 VENTILATION VENTILATION www necvisualsystems com LT260 260K Page 4 of 7 ...

Page 5: ...grams show the cabinet dimensions for the LT260 Dimensions are in inches For millimeters multiply by 25 4 FOR CEILING MOUNT 3 M4x10 2 559 4 213 1 594 7 283 2 303 8 799 0 984 VENTILATION SECURITY SLOT www necvisualsystems com LT260 260K Page 5 of 7 ...

Page 6: ...e in inches For millimeters multiply by 25 4 The LT60CM comes with a threaded pipe base and a flush base for minimal mount height 3 54 8 12 0 59 4 00 4 47 3 75 Cable Management 1 5 NPT 7 52 Threaded Pipe Base 3 50 7 52 3 99 8 12 2 38 0 59 2 84 Flush Base 0 5 0 1 75 1 99 1 99 3 99 www necvisualsystems com LT260 260K Page 6 of 7 ...

Page 7: ...H SOUND MUTE OFF 02H 13H 00H 00H 00H 15H ON SCREEN MUTE ON 02H 14H 00H 00H 00H 16H ON SCREEN MUTE OFF 02H 15H 00H 00H 00H 17H Cable Connection Communication Protocol Baud Rate 38400 bps Data Length 8 bits Parity No Parity Stop Bit One bit X on off None Communications Full duplex PC Control Connector DIN 8P To RxD of PC 1 2 3 4 5 6 7 8 To TxD of PC To GND of PC NOTE 1 It is recommended to set the p...