background image

Copyright © 1999    HC18000028INM39

ONLINE:

NascoHealthcare.com

EMAIL:

[email protected]

PHONE:

1.800.431.4310

ADDRESS: 

901 Janesville Ave. 

Fort Atkinson, WI 53538

HEALTHCARE

HEALTHCARE

Advanced Skin & Vein 

Replacement

LF01122U (Light)

LF01123U (Dark)

LF01124U (Vein)

INSTRUCTION MANUAL

Other Available

Simulators

WARNING:

 Products may contain dry natural rubber. Do not remove film from tubing.

LF01139U

LF01007U

LF03637U

LF00958U

LF00698U

  Adult Injectable Arm (Light)

LF00958U

  Pediatric Injectable Arm

LF00961U

  Intramuscular Injection

LF00995U

  Arterial Puncture Arm

LF00999U

  Pediatric Injectable Head

LF01005U

  First Aid Arm 

LF01007U

  Adult IV Foot 

LF01008U

  Intradermal Injection Arm

LF01012U

  Heart Catheterization (TPN)

LF01036U

  Spinal Injection

LF01037U

  Hemodialysis Practice Arm

LF01087U

  Central Venous Cannulation

LF01108U

  Infant Intraosseous Infusion

LF01121U

 

Advanced IV Arm

LF01131U

 

Venipuncture and Injection Arm

LF01139U

  Advanced IV Hand

LF01162U

  Venatech IV Trainer

LF01184U

  Venatech IM & Sub Q 

LF03616U

  Complete Child 

CR

i

S

is

 Manikin

LF03617U

  Deluxe Child 

CR

i

S

is

 Manikin with 

Arrhythmia Tutor

LF03620U

  PALS Update Kit

LF03632U

  Child Intraosseous Infusion/Femoral 

Access Leg on a Stand

LF03636U

  Infant IV Leg 

LF03637U

  Infant IV Arm 

LF03709U

 Infant 

CR

i

S

is

 Manikin

LF03770U

  Chest Tube

LF03953U

 

CR

i

S

is

 Manikin, Complete

LF03955U

 Deluxe 

CR

i

S

is

 Manikin

LF03956U

  Deluxe “Plus” 

CR

i

S

is

 Manikin

LF03965U

  Adult 

CR

i

S

is

 Auscultation 

Manikin

LF03966U

 Adult 

CR

i

S

is

 Auscultation 

Manikin with ECG Simulator

LF04000U

 

GERi™/KERi™

 Manikin Series

HC18000028INM39_OldMani.indd   1-2

11/15/18   9:06 AM

Summary of Contents for LF01122U

Page 1: ...theterization TPN LF01036U Spinal Injection LF01037U Hemodialysis Practice Arm LF01087U Central Venous Cannulation LF01108U Infant Intraosseous Infusion LF01121U Advanced IV Arm LF01131U Venipuncture and Injection Arm LF01139U Advanced IV Hand LF01162U Venatech IV Trainer LF01184U Venatech IM Sub Q LF03616U Complete Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin with Arrhythmia Tutor LF...

Page 2: ...r IV arm has black tubing connectors discard the eight tubing adapters and proceed with just the replacement tubing If the manifold on your IV arm has two black and eight white tubing connectors you will need to use the new adapters included in the kit To connect the new adapters simply slide the eight adapters over the connec tors after the old veins have been removed After you are finished conne...

Page 3: ... the connector block is back in its correct location within the core and that the tubing is not kinked pinched or too tightly stretched Slight pinching in the finger area is normal and will not obstruct blood flow REPLACING THE VEIN TUBING A Figure 3 shows how the four vein tubing sections should be connected to the connector block The tube fittings are not shown Note All diagrams have been color ...

Page 4: ...large channel and out the hole in the upper arm Replace the muscle pad over it B Pour the remaining lubricant into the skin allowing lubricant to run down the sides See figure 7 Squeeze the skin between extended hands Work your hands back and forth up and down the skin to coat the inside of the skin thoroughly C Grasping the skin with both hands slide the skin down over the core until the fingers ...

Page 5: ...large channel and out the hole in the upper arm Replace the muscle pad over it B Pour the remaining lubricant into the skin allowing lubricant to run down the sides See figure 7 Squeeze the skin between extended hands Work your hands back and forth up and down the skin to coat the inside of the skin thoroughly C Grasping the skin with both hands slide the skin down over the core until the fingers ...

Page 6: ... the connector block is back in its correct location within the core and that the tubing is not kinked pinched or too tightly stretched Slight pinching in the finger area is normal and will not obstruct blood flow REPLACING THE VEIN TUBING A Figure 3 shows how the four vein tubing sections should be connected to the connector block The tube fittings are not shown Note All diagrams have been color ...

Page 7: ...theterization TPN LF01036U Spinal Injection LF01037U Hemodialysis Practice Arm LF01087U Central Venous Cannulation LF01108U Infant Intraosseous Infusion LF01121U Advanced IV Arm LF01131U Venipuncture and Injection Arm LF01139U Advanced IV Hand LF01162U Venatech IV Trainer LF01184U Venatech IM Sub Q LF03616U Complete Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin with Arrhythmia Tutor LF...

Reviews: