 ME55 Programmable Heating Thermostat with LCD Screen

 

User manual 

Shenzhen Myuet Energy Saving Equipment Co., Ltd.

 

 1 

 

Programmable Heating Thermostat with LCD Screen 

Weekly circulation, it is possible to set 6 periods called events 
each day with corresponding  pre-set temperatures. You can 
select 

period control mode

 or 

manual mode

 according to your 

requirement. The thermostat is recommended for control of 
electric heating devices or on/off valve actuator used in water-
based system. 

Availability 

Mode 

Current 

Application 

ME5503 

3A 

For control of electric  actuator or 
electrothermal actuator  

ME5516 

16A 

For control of electric  actuator or 
electrothermal actuator 

ME5523 

3A 

For control of electric  actuator or 
electrothermal actuator, a potential a 
potential-free output 

ME5533 

3A 

A pair of contacts for potential-free output 

 

Technical data 

Voltage:  110-230V AC ,50/60Hz 
Power consumption:  2W 
Temperature setting range: 5-95

 

Temperature limitation range: 5-60

(factory setting: 35

Switching differential: 0.5-10

 adjustable, factory setting 

±

1

 

Ambient temperature: -5~50

 

Protective housing: IP20 

Housing material: anti-flammable PC 

Dimensions(H/W/D): 90/86/43mm 

User Operation 

1)

 

Power key 

 

 

Press the key to turn on/off the thermostat, you can also 

confirm and exit through it when completing the setting of 

every parameter. 

2)

 

The increase key 

 and decrease 

key”

 

P

ress “

” or”

”key to

 adjust temperature and the value of 

pre-set temperature will be increased/decreased by 0.5

 each 

time in “manual mode” or “ period control mode”

. Furthermore, 

in “period control mode” apart from value change its alternate 

display also stops, it will recover the alternate display with no 
operation for 3 seconds. 

3)

 

Time setting  
Press 

 

 

 key and  hold for 5 seconds 

simultaneously to adjust time. Press 

 

 to choose 

object for adjusting ; press 

” or”

 to increase 

/decrease your set values. Press 

to confirm and exit. 

4)

 

Mode selection key 

 

 

You can select “period control mode” or “manual mode” by 
this key. In “ period control mode”, it displays the time or 

the pre-set temperature alternately, and the measured 

temperature displayed directly. Press 

 and hold for 

5 seconds to enter the mode of period programming. 

5)

 

Locking 

 

 and unlocking 

Press 

 and  

 

simultaneously and hold for 5 seconds, 

the thermostat will be locked / unlocked. When locked, no 
operation can be carried out until it is unlocked. 

Display symbols 

        

     Manual mode 

         

       Period control mode 

          

      

        Wake-up, event 1 

          

      Leave, event 2 

           

      Return(am), event 3 

          

       Leave(pm), event 4 

          

       Return(pm), event 5 

            

    

        Sleep, event 6 

           

      Heating on 

Programming: 6 

event time and temperature 

Press  

 

 key and hold for 5 seconds to enter programming 

mode. 

Key 

Event 

Symbol 

Time 

 

 

Default 
value 

 

 

 

     
W

ee

da

 

06:00 

           

Se

t ti

m

20

 

        

Se

t te
m

pe

ra

tu

re

 

 

08:00 

15

 

 

11:30 

15

 

 

12:30 

15

 

 

17:00 

22

 

 

22:00 

15

 

W

ee

ke

nd

 

 

08:00 

22

 

 

23:00 

15

 

 

Advanced setting (qualified person preferred) 

Press 

 

and 

  at the same time to enter the mode of 

advanced setting immediately when thermostat is turned off. The 
following ten functions can be chosen by 

 

 key. 

Symbol 

Setting 

or 

 

ADJ 

Temperature 
calibration 

Adjust measured 
temperature 

SEN 

Sensor mode 

IN: built-in sensor 
OUT: floor sensor 

ALL: both sensor 

LIT 

Limitation 

temperature 

Adjust limitation 

value, limitation 
range:5-60

DIF 

Switching 
differential 

Adjust switching 
differential 

LTP 

 Anti-frozen function 

Turn on/off Anti-
frozen function 

PRG 

Kinds of  periods of 
time mode 

5+2 day mode 
6+1 day mode 

7 day mode 

RLE 

Potential 

free 

output and main 

power output in the 
same/different way 

Change the 

present linkage 

way 

DLY 

Delay time of 
potential-free output 

Change linkage 
delay time 

HIT 

Max .temperature 

Max. limitation 
temperature 
setpoint: 95

 

 

AFAC 

Reset to factory 

setting 

Press 

 and 

hold for 5s then 

all parameters will 
be reset. 

 

 

 