background image

 

 

 

 

ENGLISH 

MANUAL 

X2 Club 
Timing system  

PRODUCTCODE 

00012345 

 

VERSION 1 

Summary of Contents for 15R091

Page 1: ...ENGLISH MANUAL X2 Club Timing system PRODUCTCODE 00012345 VERSION 1...

Page 2: ...correct no liability can be accepted by MYLAPS for loss damage or injury caused by any errors or omissions in this document The sale of products services of standard Terms and Conditions of Sales This...

Page 3: ...and Tips Important Reference Download options X2 utility About this Manual This manual is intended for operating and supervisory personnel and provides information on installing and operating the X2...

Page 4: ...stallation of a detection loop on an asphalt track 17 3 4 Installation of a detection loop on a dirt track 20 4 Operating the MYLAPS X2 server 23 Information display status of the X2 Server 23 5 Opera...

Page 5: ...track data is not only transmitted from the X2 Transponders to the System but it will be possible to send vital race data back to the racer which is displayed through their own on board displays Track...

Page 6: ...e Portal Create your track Select the rights sport transponder type otherwise no detection either in X2 Utility or in Orbits A week before your event Create your event Create competitors list with tra...

Page 7: ...coax cable 50 meter Incl coax cable 100 meter Choose your sport 30R001 30R002 30R003 30R004 30R005 30R006 Detection loop end box 10 meter 20 meter Choose your sport 30R010 30R011 Connection box with C...

Page 8: ...1 year 10R611 2 year 10R612 5 year 10R615 X2 transponder Kart Rechargeable 1 year 10R641 2 year 10R642 5 year 10R645 Direct Power 1 year 10R651 2 year 10R652 5 year 10R655 X2 transponder MX Rechargea...

Page 9: ...wer consumption Approx 5W Network Interfaces 10 100BT RJ45 Auxiliary connections 1x 5VDC 100mA output 1x Opto coupled closing contact Max 50mA output 3x Opto coupled 5 12 VDC 5 15 mA input Auxiliary c...

Page 10: ...Max 90 non condensing 2 5 Safety instructions Clean only with a dry cloth Do not use liquid cleansers or aerosol cleaners Do not install equipment near any heat sources such as radiators heaters stove...

Page 11: ...ights reserved 11 2 6 Compatibility Specifications are subject to change without notice TR2 Transponder X2 Transponder X2 Link X2 Baselink X2 Pro transponder Flex Transponders Classic transponders Tra...

Page 12: ...X2 Timing System Club V1 0 2018 MYLAPS rights reserved 12 Tranx Pro Rental kart fixed power...

Page 13: ...l data of all decoders The X2 server has a built in practice mode that allows automatic uploads of practice results to MYLAPS X2 Decoder The decoder determines the exact time at which each transponder...

Page 14: ...iliary equipment to the decoder Use the UTP cable to connect the red port on the server to the decoder decoder to the server use an optional switch if more decoders are used Attach the GPS antenna to...

Page 15: ...an be powered over a single UTP port In this case any port can be used and the display will show a PoE or PoE icon Use the UTP cable to connect the blue port on the Server to a local computer network...

Page 16: ...rs to the cars bikes or karts When you set up a track make sure your have enough network cables on the right place Contact a network administrator if you want to use more network cables The MYLAPS X2...

Page 17: ...t the transponder is above the centre of the detection loop when the front of the vehicle crosses the finish line The width of the detection loop should exceed the width of the track by 60cm 2ft 30cm...

Page 18: ...Solder the loop wire to the wire end of the connection box with activator When soldering the wires together the solder should flow through the entire connection and not only around it 4 Put the shrink...

Page 19: ...the same procedure at the start of each race event 1 You can determine if your loop is functioning correctly by doing the following tests 2 Connect the detection loop to the decoder and computer runn...

Page 20: ...the transponder is above the center of the detection loop when the front of the vehicle crosses the finish line The width of the detection loop should exceed the width of the track by 60cm 2ft 30cm 1f...

Page 21: ...he wires of the detection loop through plastic conduits and cut the excess length of the detection loop wires When pulling the detection loop wire through the plastic conduit it is a good idea to pull...

Page 22: ...e by other electrical equipment in the area or a bad loop installation Try switching off any suspected equipment or removing nearby objects and check for improvements Especially at night short wave ra...

Page 23: ...onnecting the server to the mains will automatically switch the system on Information display status of the X2 Server Blinks when GPS receiver is attached lit when decoder is receiving UTC time from s...

Page 24: ...r and decoder or timing network F Network connection between server and decoder or timing network G Power connection for 12 VDC power supply Note The LED s on the UTP ports will show if a physical net...

Page 25: ...1 30 noise level is ok 30 50 noise level is medium 50 noise level is high not reliable detection Formula to calculate ambpoints 100 35 x dBm value 289 e g 84 dBm in AMb points 100 35 x 84 289 46 AMb F...

Page 26: ...ut Auxiliary 3 GPS Connect the GPS antenna cable and place the antenna where it has a clear view of the sky overhead to be able to make connections to satellites 4 Can connector For future use 5 The n...

Page 27: ...n in dBm 4 Indication that hits are received remains black when a transponder is being received by the loop 5 Last received signal strength of the transponder 6 Strength of last received transponder i...

Page 28: ...owledge button Please note that you can go one step back by selecting and clicking the Acknowledge button By clicking on the Acknowledge button you will see the following screens Information display s...

Page 29: ...CP Dynamic Host Configuration Protocol to get an IP address which is in the range of the network Please note that it can take about 60 sec to obtain the settings via DHCP IP Address IP address of your...

Page 30: ...llations Main functions The utility incorporates the following functions Network discovery of compatible X2 hardware Firmware upgrade assistance Configuration of individual components Component diagno...

Page 31: ...X2 Utility in web server To download the software you must make sure that your X2 server connects to the same network as your computer is powered on and fully started A connected and working server re...

Page 32: ...e agreement and click on next The installation will start Here you can choose the place where you want to put your file Both components X2 utility and bonjour must be marked on the next page A file ha...

Page 33: ...as your computer If you are still having trouble connecting to your server the network might be blocking attempts of the utility to discover the server s You can choose to connect to the server s man...

Page 34: ...ghts reserved 34 When successfully connected to the server you will be presented with an overview of all configured loops and connected decoders Click on the decoder to choose your decoder Your X2 ser...

Page 35: ...iew The connected server overview shows the type of sport selected server time remote support status and X2 Utility version Connected decoders show up as enabled not greyed out Basic component informa...

Page 36: ...IP address can be obtained it will be necessary to configure a static IP address subnet and gateway and DNS server Please consult your network provider or administrator when configuring a static IP ad...

Page 37: ...X2 Timing System Club V1 0 2018 MYLAPS rights reserved 37 Synchronization GPS decoders need a connected GPS antenna Time zone Select the appropriate time zone for your location...

Page 38: ...r When no data is recorded you should double check that the s your timing software when available Mode Set the server in main or in backup mode In main mode the server is able to write settings to the...

Page 39: ...s On this screen you can set the credentials for the X2 administrator and user accounts Administrator The administrator can change the settings of the X2 server and decoders User The user cannot chang...

Page 40: ...ained it will be necessary to configure a static IP address subnet and gateway and DNS server Please consult your network provider or administrator when configuring a static IP address for your decode...

Page 41: ...V1 0 2018 MYLAPS rights reserved 41 Loop Track sensors Select the number of installed track sensors up to 3 2 way identification If used select the ID for outgoing messages from the loop to the trans...

Page 42: ...ere you can tune the sensitivity of the loop when detecting a passing transponder A higher number has a limiting effect on transponder detection This is typically used when loops are installed in prox...

Page 43: ...Hold off The hold off in milliseconds tells the detector to ignore subsequent signal changes after the triggering edge is detected for the specified number of milliseconds This is typically used to i...

Page 44: ...l inputs can be triggered by a 5 VDC 5 15 mA pulse Figure 1 explains the connection setup To use a photocell connect it using the MYLAPS photocell cable or make an appropriate cable using figure 1 bel...

Page 45: ...X2 Timing System Club V1 0 2018 MYLAPS rights reserved 45...

Page 46: ...Email info mylaps com MYLAPS Americas Office Atlanta USA Tel 1 678 816 4000 Email info americas mylaps com MYLAPS APAC Office Sydney Australia Tel 61 2 9533 1100 Email info asia pacific mylaps com MYL...

Page 47: ...EC Radio Telecommunications Terminal Equipment Directive Has been designed and manufactured to the following specifications EN 301 489 1 2005 09 EN 301 489 3 2002 08 EN 302 208 2 2008 04 EN 61000 3 2...

Page 48: ...EC Radio Telecommunications Terminal Equipment Directive Has been designed and manufactured to the following specifications EN 301 489 1 2005 09 EN 301 489 3 2002 08 EN 302 208 2 2008 04 EN 61000 3 2...