background image

A152/FG-BF4 Series

Rounded Box Barrier-Free Wall Mount Bi-Level Drinking

Fountain with Sensor Activated Bottle Filler 

A152400F-BF4 / A152400S-BF4 / A152400F-FG-BF4 / A152400S-FG-BF4 

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

** U.S. DESIGN PATENT  D545,607 (Bowl Design)

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

LIMITED WARRANTY - UNITED STATES & CANADA

Murdock warrants that its products are free from defects in material or workmanship under normal use and 
service for a period of one year from date of install or for 18 months after the date of shipment from the factory, 
whichever comes first. Murdock’s liability under this warranty shall be discharged solely by replacement or repair 
of defective material, provided Murdock is notified in writing within one year from date of shipment, F.O.B. 
Industry, California. 

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

LIMITED EXPORT WARRANTY - 

One year on parts only. 

COMPLIES 

WITH

7020-951-001

      

Date: 02/02/18

Test rating conditions are
compliant with ARI 1010.

Federal
Public Law
111-380 
(No Lead)

Member of

 

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

www.murdockmfg.com

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

Summary of Contents for A152/FG-BF4 Series

Page 1: ...ot cover installation or labor charges and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or di...

Page 2: ...dels NOTES Dimensions shown for Adult ADA compliant installation For Child ADA compliant parallel approach installation decrease height of installation by 3 inches Provide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O...

Page 3: ... A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 BF4 Page 3 of 22 Revised 02 02 18 7020 951 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 10 185 8 6 145 8 27 8 32 321 4 143 4 23 111 2 12 33 13 8 ...

Page 4: ...15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 16 8 38 C L 2 1 General Notes 1 Dimension indicated with is for 33 drinking fountain discharge height if discharge height differs adjust accordingly 2 Standard Bi Level rough ins shown For RBL Reverse Bi Level RBL Mounting Frame rough ins opposite 1 1 4 O D Drinking F...

Page 5: ...fg com Member of 301 4 311 8 16 Finished Floor 1 2 561 4 Installation Instructions A Provide 30 1 4 wide x 31 1 8 tall wall opening at appropriate height Provide structure support around inside of the opening for frame anchoring B Carefully remove Bi Level Mounting Frame 1 and panel from packaging preventing damage C Center frame within wall opening with side top and bottom lips overlapping outsid...

Page 6: ...ncluding water supply drain pipe and gravel drain well See rough in details 5 Electrical Receptacle s must be wired to a GFCI protected circuit Fixture must be earth grounded per NEC National Electrical Code 6 Completely flush water supply lines of all foreign debris before connecting to the fixture A152 BF4 SERIES DRINKING FOUNTAIN INSTALLATION 1 Insert Mounting Frame into the Rough In Block Out ...

Page 7: ...ground neutral hot within the electrical box NOTE BEFORE PERFORMING STEP 4 REFER TO ELECTRICAL INSTALLATION 4 Test for leaks and proper operation and then install the Bottle Filler Panel using the Water Filler Bracket and secure the Bottle Filler by tightening the Screws under the Bottle Filler DRINKING FOUNTAIN START UP 1 Before connecting power supply but after thoroughly flushing the supply lin...

Page 8: ... Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of WATER TUBING CONNECTIONS PE Tubing PE Tubing Fill Spout 9 12VDC Solenoid Valve Solenoid Valve Outlet Elbow w Flow Control Solenoid Valve Inlet Fitting 3 Way Divider Assembly Y Strainer Increase Flow Decrease Flow Flat Tip Screwdriver Increase Flow Decrease Flow A152FG BF4 ...

Page 9: ...L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS FILTER MOUNTING DETAIL BACKVIEW Out In Mount Filter Bracket to Corner of Mounting Frame 1 2 3 4 5 In Out Connect 1 4 Tubings to Drinking Fountains and Bottle Filler Valve 7 6 WATER TUBING DIAGRAM 7 7012 055 000 Foam Pipe Insulation 6 2169 000 000 Tubing 1 4 O D LLDPE Blue 5 7012 311 000 WF1 Filter 1500 Gallon 4 1895 709 ...

Page 10: ...OUNTAINS FILTER MOUNTING DETAIL BACKVIEW 1 2 3 4 5 WATER TUBING DIAGRAM In Out Connect 1 4 Tubings to Drinking Fountains and Bottle Filler Valve 6 Mount Filter Bracket to Corner of Mounting Frame 8 1 4 Supply from Y Strainer 1 4 Outlet from WF3 8 1895 710 000 Union Tee 1 4 Push In 7 7012 055 000 Foam Pipe Insulation Not Shown 6 2169 000 000 Tubing 1 4 O D LLDPE Blue 5 7012 311 000 WF1 Filter 1500 ...

Page 11: ... CARTRIDGE REPLACEMENT 1 Remove front panel this allows access to the filter and the inlet valve provided by others Turn inlet valve knob 1 4 turn clockwise to close 2 With the filter assembly secured on the unit hold the cap firmly turn the replaceable cartridge filter counterclockwise to remove 3 Remove and replace the cartridge turning clockwise to secure 4 Turn inlet valve knob 1 4 turn counte...

Page 12: ...S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS ELECTRICAL INSTALLATION NOTE Plug in power is a standard feature 1A Plug In Operation Plug transformer provided into GFCI protected electrical service used by the semi recessed bottle filler Plug in transformer to power supply and connect to red sensor wire Red Wire Blue Wire Sensor ...

Page 13: ... S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS BCT BOTTLE COUNTER DISPLAY SENSOR ELECTRICAL INSTALLATION Solenoid Connection Power Supply Connection Black Cables Sensor Connection Black Red Cables Sensor Connection Transformer Solenoid Valve Bottle Count Display Senso...

Page 14: ...ounter Has Multiple Functions Reset Mode Button Counts refilled bottles otherwise purchased Adjustable for Units with and without filters REPLACEMENT FILTER alert function Alert reset when filter is replaced Description Illuminated LCD display counts bottles and has a filter replacement alert function Bottle Counting Function The software applies a flow volume of approximately 16 9 fl oz volume in...

Page 15: ... the Reset Mode Selection Button DO NOT USE SHARP OR METAL IMPLEMENTS With this reset button you are able to indicate whether or not the unit has a filter or does not have a filter The reset button will also take away the REPLACE FILTER alert once the filter has been replaced Systems With or Without Filter Depress the Reset Mode selection button for 6 Seconds the number of seconds will count up on...

Page 16: ...e Tube should not come free from the fitting Water test the connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE ...

Page 17: ...s loose or wires cut 3 WATER DRIPS OR WILL NOT SHUT OFF a Open fixture Loosen nuts holding valve bracket assembly to bottom of fixture but do not remove Move complete valve bracket assembly further back from the front push pad and tighten to lock in place b Replace valve cartridge SENSOR TROUBLE SHOOTING 4 IF LIGHT WITHIN SENSOR DOES NOT FLASH ONCE WHEN USER IS WITHIN RANGE a Verify 120VAC input 9...

Page 18: ...units 5 Stainless steel should be kept clean at all times If a coating of stainless steel cleaner polish is maintained stainless steel surfaces will retain their new clean polished appearance indefinitely DRINKING FOUNTAIN CARTRIDGE REPLACEMENT STRAINER MAINTENANCE Note Use the universal maintenance tool to perform the following 1 Strainer plug must be removed before cartridge replacement and stra...

Page 19: ...eject Allen Flat Head Screw 14 7000 100 199 Black Delrin Shaft 5 7000 021 001 Y Strainer 13 0341 100 000 Wire Clip 4 7000 005 199 Drain Adapter 12 7001 008 001 Valve Activation Assembly 3 7000 006 000 Flat Drain Adapter Gasket 11 0331 004 000 Flat Washer 2 0116 016 000 Phillips Truss Head Screw 10 0308 009 000 Nylon Insert Locknut 1 7000 005 199 Drain Adapter 9 7000 050 000 Valve Assembly ITEM PAR...

Page 20: ... murdockmfg com Member of A152FG BF4 DRINKING FOUNTAIN PARTS BREAKDOWN 1 0112 002 000 Center Reject Allen Button Head Screw 7A 7000 012 001 Stainless Steel Bubbler 2 7000 015 000 1 1 4 Reject Allen Button Head Screw 7B 7000 099 002 Flexible Bubbler Assembly 3 7000 021 001 Y Strainer 8 7000 068 001 Retaining Ring Button Assembly 4 7000 005 199 Drain Adapter 9 7000 069 001 Valve Cartridge with Foam ...

Page 21: ...C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 BF4 Page 21 of 22 Revised 02 02 18 7020 951 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 31A 26 27 28 29 32 33 34 35 37 36 38 30 10 11 12 13 18 16 19 ...

Page 22: ...Hex Nut 28 7013 114 001 Screen Plate BF4 Weldment 27 7013 103 199 Mesh Screen 26 0116 013 000 10 32 x 3 4 Phillips Round Head Screw 25 Contact Factory 18 Drinking Fountain Assembly 24 Contact Factory 14 Drinking Fountain Assembly 23 7014 042 199 Trim Panel Upper RBL w Rect Fountains 7014 062 199 Trim Panel Upper Bl w Rect Fountains 22 7000 245 000 Back Panel Spacer 21 0302 011 000 6 32 UNC Stainle...

Reviews: