NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

LIMITED WARRANTY - UNITED STATES & CANADA

LIMITED EXPORT WARRANTY - 

One year on parts only. 

Murdock warrants that its products are free from defects in material or workmanship under normal use and 
service for a period of one year from date of install or for 18 months after the date of shipment from the factory, 
whichever comes first. Murdock’s liability under this warranty shall be discharged solely by replacement or repair 
of defective material, provided Murdock is notified in writing within one year from date of shipment, F.O.B. 
Industry, California. 

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

COMPLIES 

WITH

7021-020-001    

 Date: 10/28/2020

Federal
Public Law
111-380 
(No Lead)

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

Member of

15125 Proctor Ave, City of Industry,

CA, 91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

www.murdockmfg.com

 

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Summary of Contents for A151-VR Series

Page 1: ...ing or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of a...

Page 2: ...nsions as required to comply with federal state and local codes A151 VR Page 2 of 11 Date 10 28 2020 7021 020 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS GENERAL NOTES 1 ALL DIMENSIO...

Page 3: ...tor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of SUPPLIED WALL MOUNTING PLATE 1 1 1 4 OD WASTE OUTLET 2 3 8 NCT SUPPLY INLET 3 CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS 2 10 3 1 21 2 3 8 271 4 295 8 28 33 2 ...

Page 4: ...CHALK LINE TO LOCATE BOTTOM MOUNTING HOLES 3 REFERENCE DISCHARGE HEIGHT REQUIREMENTS FOR YOUR MODEL AND FACILITY TO DETERMINE CORRECT HEIGHT AT FINISHED FLOOR AFF AFTER POSITIONING PLATE CORRECTLY FIX PLATE TO WALL USING APPROPRIATE INSTALLER PROVIDED ANCHORING HARDWARE 4 MAKE UP APPROPRIATE SUPPLY 5 AND WASTE 6 ROUGHS THROUGH MOUNTING PLATE OPENINGS LOCATE 5 16 THREADED STUDS MOUNTING HARDWARE AN...

Page 5: ...of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of WATER TUBING CONNECTIONS CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS PE Tubing Mounting Plate 3 8 O D Copper Inlet ...

Page 6: ...ter supply systems in which quick acting valves are installed shall be provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve These pressure absorbing devices shall be approved mechanical devices Water pressure absorbing devices shall be installed as close as possible to the quick closing valve 1 Read all installation instructions carefully...

Page 7: ...TTOM FLANGES 2 ARE AGAINST FINISHED WALL SECURE TO WALL FROM THE TOP SIDES AND BOTTOM USING INSTALLER PROVIDED HARDWARE 3 C INSTALL TRIM PANEL 4 BY ENGAGING OVER JOGGLE 5 ON TOP OF FRAME 1 SEE ENGAGEMENT DETAIL D ASSEMBLY OF DRINKING FOUNTAIN THROUGH TRIM PANEL 4 INTO MOUNTING FRAME 1 HELPS SECURE TRIM PANEL 4 INTO ONTO WALL 4 5 ENGAGEMENT DETAIL NOTE TRIM PANEL FIXTURE MOUNTING POINTS 6 DIFFER TO...

Page 8: ...HE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be s...

Page 9: ...er Thermostat The water temperature can be adjusted using a slotted screwdriver and turning clockwise to make colder and counterclockwise to make warmer A151 VR Page 9 of 11 Date 10 28 2020 7021 020 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 3 Periodically remove fountain top and clean out in l...

Page 10: ...t Ports on the Cartridge with the Ports in the Valve Body 1 Strainer Plug must be removed before Cartridge replacement and Strainer maintenance no need to turn the water off at the Angle Stop Some residual water will drainduring Plug removal 2 Clean Strainer as needed using clean water NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW Push in Fittings Strainer Plug Removal of P E Tubing from...

Page 11: ...r 9 7003 193 000 Spring Pushbutton Return 2 0116 016 000 10 32 x 3 8 Phillips Truss Head Screw 10 7003 196 199 Pushbutton Chrome 3 7000 006 000 Flat Drain Adapter Gasket 11 7003 197 199 Escutcheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 0161 062 000 6 32 x 1 2 Phillips Flat Head Screw 5 0152 010 000 10 32 x 1 Hex Flat Head Screw 13 0124 055 000 8 x 3 4 Phillips Round Head Screw 6A 7000 012 001 St...