background image

Conduit

®

Cat 4 for EU/UK

MTCDT-L4E1 Hardware Guide

Summary of Contents for Conduit MTCDT-L4E1

Page 1: ...Conduit Cat 4 for EU UK MTCDT L4E1 Hardware Guide ...

Page 2: ...TION OR ACCESSIBILITY TO ANY CELLULAR COMMUNICATIONS NETWORK MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES DAMAGES OBLIGATIONS PENALTIES DEFICIENCIES LIABILITIES COSTS OR EXPENSES INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR COMMUNICATIONS NETWORK USING THE PRODUCTS The MultiTech products and the final application of the MultiTech pro...

Page 3: ...tion 15 Frequency Bands for Conduit 15 Frequency and Power Information for WiFi Bluetooth 15 Frequency and Power Information for LoRa 15 Transmission Output Power 15 For Telit LE910C4 EU L4E1 15 Chapter 6 Setting up and Configuring the Device 16 Install and Connect Conduit Hardware 16 Installing a Mini SIM Card 16 Accessory Port mCard Interfaces 17 Installing a Micro SD Card 17 Installing a Batter...

Page 4: ... Other Medical Devices 24 Potential interference 24 Precautions for pacemaker wearers 24 Chapter 8 Environmental Notices 25 Waste Electrical and Electronic Equipment Statement 25 WEEE Directive 25 Instructions for Disposal of WEEE by Users in the European Union 25 Restriction of the Use of Hazardous Substances RoHS 25 REACH Statement 26 Registration of Substances 26 Information on HS TS Substances...

Page 5: ...nduit Document Description Part Number Hardware Guide This document provides overview safety and regulatory information design considerations schematics and general hardware information S000731 Software Guide This document provides instructions and information on how to properly configure your device through its user interface S000727 API Developer Guide You can use the Conduit API to manage confi...

Page 6: ...MTCDT L4E1 247A 868 EU GB LTE Cat 4 AEP Programmable Gateway 8 channel 868 MHz w GNSS MTAC LORA H 868 mCard Wi Fi Bluetooth and US EU UK Accessory Kit EU UK MTCDT L4E1 246A 868 EU GB LTE Cat 4 AEP Programmable Gateway 8 channel 868 MHz w GNSS MTAC LORA H 868 mCard and US EU UK Accessory Kit EU UK MTCDT L4E1 247A EU GB LTE Cat 4 AEP Programmable Gateway w GNSS Wi Fi Bluetooth and US EU UK Accessory...

Page 7: ... GNSS WiFi BT and EU UK Accessory Kit EU UK MTCDT L4E1 246L EU GB LTE Category 4 mLinux Programmable Gateway w GNSS and US EU UK Accessory Kit EU UK MTCDT L4E1 240L EU GB LTE Category 4 mLinux Programmable Gateway w US EU UK Accessory Kit EU UK Note The complete product code may end in Rx For example MTCDT L4E1 Rx where R is revision and x is the revision number ...

Page 8: ...vironmental factors Up to 50 Mbps uplink See above note Diversity MIMO Rx Diversity and MIMO DL 2x2 SMS over IMS Point to Point messaging Mobile terminated SMS Mobile originated SMS Physical Description Dimensions See the Conduit Demensions Drawing Weight 15 6 oz 442 25 grams with no accessory cards installed Connectors Connectors 1 USB device micro Type B debug port 1 RJ 45 Ethernet port 1 USB 2 ...

Page 9: ...es within IP67 enclosure or when used with the fused DC power cable part number FPC 532 DC Installation in outdoor locations or ambient above 70 C has not been evaluated by UL UL Certification does not apply or extend to use in outdoor applications Optional power must be UL Listed ITE power supply marked LPS or Class 2 rated 12 VDC 5A Certification does not apply or extend to Voltages outside cert...

Page 10: ...SPECIFICATIONS 10 Conduit Cat 4 for EU UK MTCDT L4E1 Hardware Guide Mechanical Drawing ...

Page 11: ...rt to connect the Conduit to a computer or another device By default this port is a serial port terminal interface but you can program it to act as another device such as a mass storage device or an Ethernet port E NET RJ 45 receptacle for standard Ethernet 10 100 Base T Caution Ethernet ports and command ports are not designed to be connected to a public telecommunication network or used outside ...

Page 12: ...pplication model only Signal Signal Strength These 3 LEDs display the strength of the cellular signal Present on the Conduit Application model only If a cellular radio is installed the typical LS Link Status LED behavior is the following OFF No power to the cellular radio Continuously Lit Not registered Slow Blink 0 2Hz Registered or connected On the back of the Conduit the RJ 45 Ethernet LEDs loc...

Page 13: ... 12 0 Volts eGSM 900 MHz 154 326 1 210 4 68 WCDMA 141 489 584 4 68 LTE 175 465 556 5 68 24 0 volts eGSM 900 MHz 104 191 635 3 63 WCDMA 95 282 360 3 63 LTE 115 265 316 3 63 1 Tx Pulse The average peak current during a GSM850 transmission burst period The transmission burst duration for GSM850 can vary depending on what transmission scheme is being deployed GPRS Class 8 Class 10 GSM etc 2 Total Inru...

Page 14: ...E GY115HT467 017 Model Number 11320Y11194A1 MultiTech ordering information Model Quantity ANLTE2 2HRA 1 ANLTE2 10HRA 10 ANLTE2 50HRA 50 Antenna Specifications Category Description Frequency Range 069 0 96GHz 1 71 2 17GHz 2 3GHz 2 69GHz Impedance 50 Ohms VSWR VSWR should not exceed 3 1 at any point across the bands of operation Peak Gain 3 8 dBi Radiation Omni directional Polarization Linear Vertic...

Page 15: ...483 5 MHz 19 1 dBm 802 11g 2400 MHz 2483 5 MHz 19 9 dBm 802 11n 2400 MHz 2483 5 MHz 19 9 dBm 802 11a 5150 MHz 5350 MHz 5470 MHz 5725 MHz 13 5 dBm 802 11n 5150 MHz 5350 MHz 5470 MHz 5725 MHz 13 6 dBm BT BLE 2400 MHz 2483 5 MHz 10 1 dBm Frequency and Power Information for LoRa Operating Frequency RF Output Power FCC Part 15C 923 3 MHz 927 5 MHz USA 25 1 dBm EN 300 220 2 863 1 MHz 869 9 MHz Europe 14...

Page 16: ...er strip and to the power adapter 9 Connect the power adapter to the barrel jack on the back panel of the device The Power LED comes on immediately after power is applied Wait for the Status LED to begin blinking Installing a Mini SIM Card You need Phillips screwdriver Mini SIM card 2FF form factor To install or replace the SIM card 1 Disconnect power to the Conduit if it is connected 2 At the fro...

Page 17: ...ed by Serial inteface based Accessory Cards SDIO interface and or SPI Interface AP1 has option for SDIO or SPI interface based on what Accessory Card is installed AP2 supports only SPI based Accessory Cards GPIO Additional control pins for certain Accessory Cards Interrupts Software defined interrupts Can also be used as additional control pins PPS GPS generated Pulse Per Second signal used for so...

Page 18: ...al tweezers or similar object CR1632 standard coin lithium battery To install or replace the battery 1 If connected disconnect power to the Conduit 2 At the front of the Conduit housing remove the screw that secures the MultiTech nameplate to the housing 3 The battery holder is located at the right side of the opening on the underside of the PC board To remove an existing battery use non metal twe...

Page 19: ...ing 3 Locate the USB debug cable connector in the center of the opening 4 Connect the USB Micro B cable to the debug connector 5 Connect the Type A end of the USB cable to the host 6 From the host use an application such as TeraTerm with a baud rate of 115 200 If the USB driver does not automatically install do the following a Unplug the USB cable b Go to the following web site to download and ins...

Page 20: ...the RESET button for less than 3 seconds then release The device reboots For mLinux Press and hold the RESET button for less than 5 seconds then release Holding it beyond 5 seconds resets an mLinux device to factory defaults 3 The status LED will keep blinking normally for a couple of seconds until the unit resets Then the status light will stay solid while the device reboots Once finished the sta...

Page 21: ... for battery replacement Lithium cells and batteries are subject to the Provisions for International Transportation Multi Tech Systems Inc confirms that the Lithium batteries used in the MultiTech product s referenced in this manual comply with Special Provision 188 of the UN Model Regulations Special Provision A45 of the ICAO TI IATA DGR Air Special Provision 310 of the IMDG Code and Special Prov...

Page 22: ...h has not authorized or that are not compliant with MultiTech s accessory specifications may invalidate the warranty If the device is not working properly contact MultiTech Technical Support Vehicle Safety When using your device in a vehicle Do not use this device while driving Respect national regulations on the use of cellular devices in vehicles If incorrectly installed in a vehicle operating t...

Page 23: ...ps and before filling your vehicle with fuel Switch OFF your wireless device in hospitals and any other place where medical equipment may be in use Sécurité relative aux appareils à radiofréquence RF À cause du risque d interférences de radiofréquence RF il est important de respecter toutes les réglementations spéciales relatives aux équipements radio Suivez les conseils de sécurité ci dessous Uti...

Page 24: ...vices If harmful interference occurs the FDA will assess the interference and work to resolve the problem Precautions for pacemaker wearers If EMI occurs it could affect a pacemaker in one of three ways Stop the pacemaker from delivering the stimulating pulses that regulate the heart s rhythm Cause the pacemaker to deliver the pulses irregularly Cause the pacemaker to ignore the heart s own rhythm...

Page 25: ...s that this product must not be disposed of with other waste Instead it is the user s responsibility to dispose of their waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is ...

Page 26: ...the following RoHS annex therefore higher lead concentration would be found in some modules 1000 PPM Resistors containing lead in a glass or ceramic matrix compound REACH Statement Registration of Substances Multi Tech Systems Inc confirms that none of its products or packaging contain any of the Substances of Very High Concern SVHC on the REACH Candidate List in a concentration above the 0 1 by w...

Page 27: ...方面的信息 有 有害 害 有 有毒 毒物 物质 质 元 元素 素 成 成分 分名 名称 称 铅 铅 PB 汞 汞 Hg 镉 镉 CD 六 六价 价铬 铬 CR6 多 多溴 溴联 联苯 苯 PBB 多 多溴 溴二 二苯 苯醚 醚 PBDE 印刷电路板 O O O O O O 电阻器 X O O O O O 电容器 X O O O O O 铁氧体磁环 O O O O O O 继电器 光学部件 O O O O O O ICs O O O O O O 二极管 晶体管 O O O O O O 振荡器和晶振 X O O O O O 调节器 O O O O O O 电压传感器 O O O O O O 变压器 O O O O O O 扬声器 O O O O O O 连接器 O O O O O O LEDs O O O O O O 螺丝 螺母以及其它五金件 X O O O O O 交流 直流电源 O O O...

Page 28: ...i nated Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O Diodes Transistors O O O O O O Oscillators and Crystals X O O O O O Regulator O O O O O O Voltage Sensor O O O O O O Transformer O O O O O O Speaker O O O O O O Connectors O O O O O O LEDs O O ...

Reviews: