FireHawk

®

M7 

Air Mask

OPERATION AND INSTRUCTIONS

This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:

(1) This device may not cause harmful interference and (2) this device must accept any interference that may cause

undesired operation.

TAL 1705 (L) Rev. 18

© MSA 2017

Prnt. Spec. 10000005389(A)    Mat. 10082858

Doc. 10082858

This manual must be carefully read and followed by all persons who have or will have the responsibility for using

or servicing this air mask. This air mask will perform as designed only if used and serviced according to the instruc-

tions; otherwise it could fail to perform as designed, and persons who rely on the air mask could sustain serious

personal injury or death.

This Self-Contained Breathing Apparatus (SCBA) is certified by the National Institute of Occupational Safety and Health

(NIOSH).

Changes and modifications not expressly approved by the manufacturer could void the user’s authority to operate the

equipment.

The warranties made by MSA with respect to the product are voided if the product is not installed, used and serviced in

accordance with the instructions in this manual. Please protect yourself and your employees by following the instructions.

Please read and observe the WARNINGS and CAUTIONS inside. For any additional information relative to use or repair,

write or call 1-800-MSA-2222 during regular working hours.

Summary of Contents for FireHawk M7

Page 1: ...otherwise it could fail to perform as designed and persons who rely on the air mask could sustain serious personal injury or death This Self Contained Breathing Apparatus SCBA is certified by the Nati...

Page 2: ...Always inspect the FireHawk M7 HUD or I HUD for damage before use If damage is found immediately remove the device from service The FireHawk M7 HUD or I HUD FireHawk M7 Control Module FireHawk M7 Pow...

Page 3: ...atmosphere 6 Return to a safe atmosphere immediately if discol oration crazing blistering cracking or other dete rioration of the facepiece lens material is observed 7 Users must wear suitable protec...

Page 4: ...your local MSA authorized repair center or distributor who will provide the necessary information to MSA for issue resolution To report any serious concerns or to speak with a certifica tion organiza...

Page 5: ...pirable by the user The PR14 First Stage Regulator incorporates a down stream design and dual springs The regulator incorporates a large easily replaceable sin tered filter to capture particulates tha...

Page 6: ...rforms the same functions as the FireHawk M7 HUD but it is located inside the Ultra Elite Facepiece FIREHAWK M7 CONTROL MODULE INTEGRATED PASS VERSION The FireHawk M7 Control Module is the user s inte...

Page 7: ...and cylinder The duration of the remaining air supply will be reduced by at least half The SCBA is approved by NIOSH without inter con necting two users to one apparatus NIOSH does not certify buddy...

Page 8: ...NOTES 8 TAL 1705 L Rev 18 10082858...

Page 9: ...I HUD for cracks or other signs of damage which could allow conta minants to enter the housing b Reassemble the FireHawk M7 HUD to the bracket on the Ultra Elite Facepiece or reinstall the FireHawk M7...

Page 10: ...should be stored full or empty pressure above ambient but less than 100 psi 9 FireHawk M7 Carrier and Harness a Operate the latch wing on the cylinder band to ensure that it opens and closes properly...

Page 11: ...e Attach the regulator to the facepiece Ensure proper regulator attachment by pulling on the regulator f Don the facepiece or hold the facepiece against the face to create an effective seal g Inhale...

Page 12: ...res sure gauge when the alarm rings Perform this test with a minimum cylinder pressure of 1200 psi for 2216 psi air masks 1800 psi for 3000 psi air masks and 2000 psi for 4500 psi air masks 2 Pressuri...

Page 13: ...turning the dust cover counterclockwise Do not use tools 5 If the line does not line up across the joint or across the joint where the coupling attaches to the air mask remove the air mask from servic...

Page 14: ...NOTES 14 TAL 1705 L Rev 18 10082858...

Page 15: ...lay flat across the body BEFORE USING THE AIR MASK 1 Grasp the Firehawk Regulator and push the side but tons 2 Ensure that the red bypass knob is fully closed clockwise 3 Reach behind and fully open...

Page 16: ...dy lights on the FireHawk M7 Power Module integrated PASS version should be flashing red 11 When the system pressure falls below 200 psi turn the FireHawk M7 Control Module off by depressing the reset...

Page 17: ...est again If this does not cor rect the leak do not use the facepiece 2 Test the exhalation valve a Take a deep breath and hold it b Block the facepiece inlet adapter with the palm of the hand and exh...

Page 18: ...the air mask passes all tests it is ready for use These tests must be performed every time before entering a hazardous atmosphere If the air mask fails to meet any of the tests the condition s must be...

Page 19: ...ests it is ready for use These tests must be performed every time before entering a hazardous atmosphere If the air mask fails to meet any of the tests the condition s must be corrected before using t...

Page 20: ...NOTES 20 TAL 1705 L Rev 18 10082858...

Page 21: ...si approximately 4500 psi system When the FireHawk M7 HUD or I HUD FireHawk M7 Control Module integrated PASS version or Audi Larm Alarm indicates 25 cylinder pressure immediately return to fresh air...

Page 22: ...s been confirmed 5 The FireHawk M7 HUD or I HUD has a photo sensor that automatically adjusts the brightness of the LEDs based on the intensity of the ambient light measured outside of the facepiece 6...

Page 23: ...nto the battery tube on the FireHawk M7 HUD 8 Before installing the battery cap verify that the o ring is in place and free of damage and debris If the o ring is missing or damaged replace o ring Fail...

Page 24: ...ovac Ultrapro LR03 Duracell MN2400 Duracell Procell PC2400 Energizer E92 or Eveready A92 AAA alkaline batteries in the TRANSMITTER Use of other batteries or a combina tion of batteries from different...

Page 25: ...alarm none low volume low urgency medium volume medium urgency high volume high urgency full volume high urgency with a buzz Bee none 1 beep every 5 seconds 1 beep every 3 seconds none none continuous...

Page 26: ...ssembled to the gauge line hose and is connected to the FireHawk M7 Power Module by the power cable The FireHawk M7 Control Module serves as the user interface with the air mask and it also serves as...

Page 27: ...in inaccurate data logging of the FireHawk M7 Control Module The time may be viewed or changed using the FireHawk M7 Interface Module For additional instructions on using the FireHawk M7 Interface Mo...

Page 28: ...e Display Mode can only be activated when the system is pressurized 1 Push the mode button green on the FireHawk M7 Control Module or NightFighter HUD Transmitter and hold the button in for 3 seconds...

Page 29: ...drained The FireHawk M7 Control Module does not shut off auto matically 1 Upon returning to fresh air close the cylinder valve completely and release all pressure from the air mask 2 When the pressur...

Page 30: ...NOTES 30 TAL 1705 L Rev 18 10082858...

Page 31: ...en not in use 2 When the air mask is away from heat water spray can freeze on the Firehawk Regulator surface Ice can build up and bind the side buttons or the bypass valve Before entering or re enteri...

Page 32: ...NOTES 32 TAL 1705 L Rev 18 10082858...

Page 33: ...neously doing so will void NIOSH approval The URC Assembly must be used by trained Rapid Intervention Crews only using procedures devel oped for rapid intervention DO NOT install a Quick Fill System a...

Page 34: ...diately install the dust cover on the URC Assembly 6 The air mask cylinder is ready for service if the cylin der pressure gauge needle is on the appropriate color band TRANSFILLING BETWEEN AIR MASKS N...

Page 35: ...eaking a Immediately reconnect the quick fill hose to seal off the leak and return to fresh air b If the hose will not reconnect reach behind and close the cylinder valve Air pressure in the regulator...

Page 36: ...t and away from the body 11 Slip the right arm out of the shoulder strap first and then remove the harness NOTE Be sure to replace the cylinder with a fully charged one Complete Inspection and Cleanin...

Page 37: ...rees until it stops Fold the latch wing toward backplate locking latch wing in place NOTE Be sure to completely tighten the latch wing each time a cylinder is installed 9 To check that the cylinder is...

Page 38: ...its gaseous service New labels are restricted items which are not available except through certified hydrostatic test facilities When replacing cylinder valves or after the retesting of cylinders mak...

Page 39: ...extended Place the complete air mask in the storage case or suitable storage location so it can be easily reached for emergency use For prolonged storage of the air mask remove the batter ies from al...

Page 40: ...NOTES 40 TAL 1705 L Rev 18 10082858...

Page 41: ...the facepiece to air dry Do not dry the parts by placing them near a heater or in direct sunlight The rubber will deteriorate h Operate the exhalation valve by hand to be sure it works properly NOTE...

Page 42: ...NOTES 42 TAL 1705 L Rev 18 10082858...

Page 43: ...MSA air masks must be overhauled based on the actual level of usage of the air mask rather than on time alone MSA air masks must be flow tested every year using an MSA approved flow test device The fo...

Page 44: ...NOTES 44 TAL 1705 L Rev 18 10082858...

Page 45: ...ult in serious injury or death DO NOT use the Quick Fill System URC Assembly or ExtendAire System accessories if there is any possi bility that the environment contains a CBRN warfare agent These air...

Page 46: ...ble alarm is ringing or FireHawk M7 HUD or I HUD FireHawk M7 Control Module are flashing Misuse can result in shorter escape time to return to fresh air causing serious injury or death The audible ala...

Page 47: ...dust cap on the male fitting This will form a redundant seal d Open the cylinder valve and return to fresh air immediately The dust cover prevents dirt water and debris from entering the fitting and...

Page 48: ...NOTES 48 TAL 1705 L Rev 18 10082858...

Page 49: ...use the system DO NOT use the system if the donor s audible alarm is ringing The NIOSH Approval for both apparatus are void when this device is used due to the difficulty in maneuvering during escape...

Page 50: ...gled with any other part of the apparatus i e second stage regulator hose neck strap chest strap etc c Check for full engagement by pulling at the quick dis connect and assure that the coupler does no...

Page 51: ...e intermediate pressure hose manifold 2 Attach the adapter hose Locate the end with the Snap Tite coupler Push the Snap Tite coupler onto the MMR intermediate pressure hose manifold tee Pull on the co...

Page 52: ...w the steps described below 1 Push the two sides of the quick disconnect towards each other firmly The plug end should advance into the coupler end approximately 1 8 inch 2 Slide the outer sleeve on t...

Page 53: ...Hawk M7 HUD or I HUD has a low battery condition Data Log The data logging feature of the FireHawk M7 Control Module logs the status of the radio link to the base station as well as any evacuation sig...

Page 54: ...ir mask must not be pressurized and FireHawk M7 Control Module must be turned off to scan the ID Tag 2 Take the ID Tag and place the attachment clip between your fin gers on your left hand The ID Tag...

Page 55: ...icator will stop flashing when the air mask returns within range of the base station If the signal strength indicator does not appear on the FireHawk M7 Control Module display the base station has not...