background image

 

 

 2014 Moxa Inc. All rights reserved. 

Reproduction without permission is prohibited. 

 

 

 

 

 

 

 

 

 

 

 

P/N: 1802077280015 

PT-7728/7828 

Hardware Installation Guide 

Moxa PowerTrans Switch 

Seventh Edition, January 2014 

 

 

www.ipc2u.ru

www.moxa.pro

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for PowerTrans PT-7728

Page 1: ...tion without permission is prohibited P N 1802077280015 PT 7728 7828 Hardware Installation Guide Moxa PowerTrans Switch Seventh Edition January 2014 www ipc2u ru www moxa pro All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ... Warranty Statement RJ45 to DB9 console port cable Protective caps for unused ports 2 rack mount ears Panel Layout 1 System status LEDs 2 Interface Module mode LEDs 3 Interface Module port LEDs 4 Push button switch to select mode for Interface Module 5 Model Name 6 Fast Ethernet Interface Modules 7 Gigabit Ethernet Interface Modules 8 Serial Console port 9 10 pin terminal block for power inputs an...

Page 3: ... 3 Dimensions unit mm Fast Ethernet Interface Modules slots 1 2 and 3 www ipc2u ru www moxa pro All manuals and user guides at all guides com ...

Page 4: ...rrent allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Grounding Moxa PowerTrans Switch Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices Wiring the Power In...

Page 5: ...the Redundant Power Inputs Each PT switch has two sets of power inputs power input 1 and power input 2 STEP 1 Insert the dual set positive negative DC wires into PWR1 and PWR2 terminals pins 1 9 pins 2 10 Or insert the L N AC wires into PWR1 and PWR2 terminals L pin 1 9 N pin 2 10 STEP 2 To keep the DC or AC wires from pulling loose use a screwdriver to tighten the wire clamp screws on the front o...

Page 6: ...Off The corresponding PORT alarm is enabled and a user configured event has not been triggered or the corresponding PORT alarm is disabled MSTR HEAD GREEN On This PT switch is set as the Master of the Turbo Ring or as the Head of the Turbo Chain Blinking The PT switch has become the Ring Master of the Turbo Ring or the Head of the Turbo Chain after the Turbo Ring or the Turbo Chain went down Off T...

Page 7: ...n port of this PT switch Off The corresponding module s port is not the ring or chain port of this PT switch COUPLER PORT GREEN On The corresponding module s port is the coupler port of this PT switch Off The corresponding module s port is not the coupler port of this PT switch Specifications Technology Standards IEEE 802 3 802 3u 802 3ab 802 3z 802 3x 802 1D 802 1w 802 1Q 802 1p 802 1X 802 3ad Fl...

Page 8: ...etal case Dimensions W x H x D 440 x 44 x 325 mm 17 32 x 1 73 x 12 76 in Weight 5900 g Installation 19 rack mounting Regulatory Approvals Safety UL60950 1 CSA C22 2 No 60950 1 EN60950 1 Power Automaton IEC61850 3 IEEE 1613 Road Traffic NEMA TS2 Rail Traffic EN50121 4 EN50155 EMI FCC Part 15 CISPR EN55022 class A Environmental Limits Operating Temp 40 to 85 C 40 to 185 F Cold start of min 100 VAC a...

Reviews: