background image

 

 

© MOBATIME 

 

BE-801318.01_ECO-SLH-DC 

 

 

 

 

 
 
 
 
 
 
 

INSTRUCTION MANUAL 

 

State-of-the-art technology digital clock 

ECO-SLH-DC series 

 

addition to the standard DC series instruction manual (for ECO-SLH-DC only) 

 

Summary of Contents for ECO-SLH-DC Series

Page 1: ...MOBATIME BE 801318 01_ECO SLH DC INSTRUCTION MANUAL State of the art technology digital clock ECO SLH DC series addition to the standard DC series instruction manual for ECO SLH DC only...

Page 2: ...in order to explain all details in respect of the operation of the product Should you nevertheless have questions or discover errors on this manual please contact us 3 We do not answer for direct or i...

Page 3: ...k with back cover 7 16 Engineering data 8 16 1 Standard design of the clock 8 16 2 Voltage range and electric current consumption of the lines 8 17 Accessories 10 17 1 Clock without back cover 10 17 2...

Page 4: ...time values either 12 or 24 hours format four or six digit HH MM or HH MM SS format display of calendar date in four or six digit DD MM or DD MM YY format display of temperature in C or F up to two s...

Page 5: ...mediate time counting in steps of 1 minute 1 second or 1 100 seconds operation via keyboard or remote IR controller possibility to connect another display unit s possibility of parallel switching over...

Page 6: ...For panel mounting drill four anchoring holes diameter 2 6mm into the panel of a diameter adequate to accommodate wood type screws of 4 5 mm diameter As a template for marking the position of the hole...

Page 7: ...n of the holes the back cover can be used Pull the incoming conductors through the hole in the back side of the cover and fix the cover to the wall or into panel using appropriate screws On mains powe...

Page 8: ...timebase passive running reserve time date 6 years except PoE running reserve PoE version 12 hours accuracy at 20 C 0 1 s day without synchronization after 24 hours of synchronization at constant tem...

Page 9: ...OBATIME 9 12 801318 01 Type of slave line Voltage range Electric current consumption MOBALine 5 30 VAC 6 34 uA MIN CODE 12 30 V 3 7 mA MIN CODE on request 30 60 V 3 7 mA IRIG B 20 mVpp 2 Vpp 20 uA 2 m...

Page 10: ...with a picture of a crossed out trash bin The symbol means that this product may not be disposed through household waste Below the symbol the dangerous substance is indicated with an abbreviation Cd...

Page 11: ...MOBATIME 11 12 801318 01...

Page 12: ...ch www mobatime ch MOSER BAER SA EXPORT DIVISION 19 ch du Champ des Filles CH 1228 Plan les Ouates Tel 41 22 884 96 11 Fax 41 22 884 96 90 export mobatime com www mobatime com MOSER BAER AG Spitalstra...

Reviews: