Installation

*INSTALLATION*

Front view

a

Mains connection cable

b

Control panel

c

Condensed water container

– empty after every drying cycle

d

Door

– do not open during drying

e

Heat exchanger access panel

– do not open during drying

f

Four height adjustable screw feet

g

Cool air intake grille

– do not obstruct with a laundry bas-

ket or other objects

h

Hose for external drainage of con-
densed water

Summary of Contents for TCB140 WP

Page 1: ... water container empty after every drying cycle d Door do not open during drying e Heat exchanger access panel do not open during drying f Four height adjustable screw feet g Cool air intake grille do not obstruct with a laundry bas ket or other objects h Hose for external drainage of con densed water ...

Page 2: ...ring transportation If the tumble dryer is being transpor ted on its side it must be tipped onto its left or right side If the tumble dryer is being transpor ted upright and you are using a hand truck you must transport it with its left or right side resting on the truck Transporting the tumble dryer to its installation site Make sure the fixings at the back of the lid are secure Otherwise there i...

Page 3: ...damage to the tumble dryer The refrigerant is flammable and ex plosive Do not make any alterations to the tumble dryer Take measures to pro tect the tumble dryer against dam age If the tumble dryer is damaged proceed as follows Avoid naked flames or anything which creates a spark Disconnect the tumble dryer from the electrical supply Air the room where the tumble dryer is located Contact the Miele...

Page 4: ...ration of this tumble dryer generates a great deal of heat inside its casing There must be a reliable means of dissipating this heat Otherwise loads could take longer to dry or the tumble dryer might sustain damage in the long term Permanent room ventilation during every drying programme and the gap between the bottom of the tumble dryer and the floor are mandatory re quirements at all times Befor...

Page 5: ...and the bottom of the dryer Create a gap for the dryer in the kit chen furniture plinth facing Create ventilation gaps in the kitchen cabinet Slot in This tumble dryer is suitable for pushing under a worktop if there is space to do this without removing the lid Optional accessories Building under kit A building under kit is required if the lid of the tumble dryer needs to be removed in order to bu...

Page 6: ... are supplied Installation conditions requiring a non return valve Danger of condensed water back flow Water could flow back into the tumble dryer or be drawn into it Back flow water could damage the tumble dryer and also the room in which it is located The non return valve should be used if the end of the hose is immersed in water or if other water connections are installed Maximum delivery head ...

Page 7: ... Have a con tainer ready to collect this Pull the drain hose off its connection light arrow Pull the hose out of the holders dark arrow and unwind it Allow any residual water to run into a container Examples Drainage into a sink or floor gully Use the hose holder to secure the drain hose Water damage Should the end of the hose come loose overflowing water can cause damage Secure the drain hose car...

Page 8: ... 6 Tumble dryer drain hose Fit adapter 1 to the sink drain outlet using nut 2 The nut is usually fitted with a washer which must be removed Attach the end of the hose 4 to ad apter 1 Use the hose holder Use a screwdriver to tighten hose clip 3 up close to the nut Fit non return valve 5 to tumble dryer drain hose 6 Non return valve 5 has to be fitted so that the arrow points in the direction of flo...

Page 9: ...egulations BS 7671 in the UK We recommend the use of a suitable RCD If the connection cable is damaged it must only be replaced with a specific connection cable of the same type available from the Miele Customer Ser vice Department For safety reasons such replacement may only be carried out by a qualified technician or the Miele Customer Service Department The data plate indicates the nominal powe...