Weekly Programmable Thermostat / Termostato semanal programable / Thermostat 

hebdomadaire programmable

 

 
 
 
 

 

 

 

MK680

 

Termostato Settimanale Programmabile

 

Cod. 493933763

 

 

 
 

 

Summary of Contents for MK680

Page 1: ...uale User manual Manual de usuario Mode d emploi Weekly Programmable Thermostat Termostato semanal programable Thermostat hebdomadaire programmable MK680 Termostato Settimanale Programmabile Cod 493933763 ...

Page 2: ......

Page 3: ...ta nella presa del timer Se è necessaria la pulizia del timer togliere l alimentazione elettrica e pulire il timer con un panno asciutto NON IMMERGERE IL TEMPORIZZATORE IN LIQUIDI DI NESSUN TIPO Tenere fuori dalla portata di bambini In caso di surriscaldamento anomalo disconnettere dalla rete elettrica Conforme alle direttive 2014 30 CE e 2014 35 CE TERMOSTATO SETTIMANALE PROGRAMMABILE MK680 MANUA...

Page 4: ...postazione Economico 19 Simbolo impostazione TEMPeratura 20 Simbolo COPY copiaimpostazioni 21 Simbolo temperatura ROOM stanza 22 Simbolo OFF spento 2 Impostazione funzioni e orologio Premere e tenere premuto il tasto SET per 3 secondi Premere il tasto SELECT per selezionare tI per l orologio o St per impostazione funzioni come da figura sottostante Premere SET per selezionare la funzione desiderat...

Page 5: ...sempre con i tasti freccia Premere SELECT per tornare all Anno Premere OK per salvare ed uscire B Impostazione funzioni Utilizzare il tasto SELECT per scegliere tra Holiday vacanze e Heat Cool caldo freddo Ho per vacanze Ht o CL per caldo freddo come da figura sotto riportata Premere SET per entrare nell impostazione Vacanze Controllo caldo freddo ...

Page 6: ...o solo se il periodo vacanze è a zero b Controllo caldo freddo imposta se controllare il caldo o il fresco e abilita o disabilita il ritardo di avvio Utilizzare il tasto SELECT per selezionare Riscaldamento o Raffreddamento Ht per riscaldamento e CL per raffreddamento come da figura Riscaldamento Raffreddamento Premere SET per confermare ed entrare nella selezione avvio ritardato abilitato o disab...

Page 7: ... ritarderà di 5 minuti ciascuna operazione del terminale NO in Chiusura e del terminale NC in Apertura NO indica il contatto del relè Normalmente Aperto e NC indica Normalmente Chiuso 3 Impostazione della temperatura L unità dispone di 4 temperature preimpostate Comfort SemiConfort Economic e Antigelo Fare riferimento alla figura sotto riportata Premere e tenere premuto il tasto TEMP per 3 secondi...

Page 8: ...e e passare all impostazione successiva Programma 7 giorni Settimana sab dom Settimana weekend Programma giorn B Quindi selezionare il giorno per impostare il programma Premere il tasto SELECT Ad esempio selezionare Monday lunedì come primo giorno da programmare nel programma 7 giorni Premere PROG per andare avanti C Impostare il programma per il giorno selezionato 1 L impostazione è dalle ore 0 0...

Page 9: ...rà sul display Premere OK per confermare Tornare indietro alla procedura sopraindicata per selezionare la programmazione del giorno successivo 6 Ripetere le procedure B e C per terminare tutti i giorni della settimana 7 Premere OK per salvare ed uscire D Revisione del programma Premere PROG per entrare nella procedura di programmazione Premere SELECT 4 volte finché 7dY appare sul display in alto a...

Page 10: ...ra successiva Il simbolo di Controllo Manuale Temporaneo compare a display B L impostazione manuale della temperatura ha la priorità premere i tasti freccia per regolare la temperatura attuale Questa priorità continuerà fino all ora successiva Il simbolo del controllo manuale della temperatura viene indicato sul display C Per mantenere temporaneamente l impostazione della temperatura attuale preme...

Page 11: ...re ed uscire 6 Allarme batteria scarica compare sul display l indicazione lampeggiante della batteria Sostituire la batteria Osservazione la durata delle batterie in questa unità è di circa UNA stagione di riscaldamento o raffreddamento 6 mesi Verificare il simbolo della batteria mensilmente 7 Specifiche Potenza gestibile 230Vac 50Hz 8A carico resistivo Rapporto termico Escursione misura temperatu...

Page 12: ...680 MK680 è formato da due parti pannello di controllo e base di commutazione Pannello di controllo Base di commutazione INSTALLAZIONE BASE DI COMMUTAZIONE A MURO 1 Praticare due fori sul muro di installazione come sotto indicato ...

Page 13: ...ili Seguire lo schema per la connessione dei fili 4 Riavvitare il coperchio 5 Utilizzare le viti fornite per avvitare la base di commutazione su una scatola 503 Oppure utilizzare gli ancoraggi forniti con i fori praticati nel muro Quindi utilizzare le viti fornite per avvitare la base di commutazione ...

Page 14: ...tallare due batterie AAA nel pannello di controllo come indicato in figura 2 Afferrare i lati sinistro e destro del pannello di controllo e premerli sulla base di commutazione Ricordare di prendere i lati sinistro e destro NON utilizzare i lati Alto e Basso ...

Page 15: ...zione 2 batterie alcaline AAA SMALTIMENTO La presenza del simbolo del bidone barrato indica che Questo apparecchio non è da considerarsi quale rifiuto urbano il suo smaltimento deve pertanto essere effettuato mediante raccolta separata Lo smaltimento effettuato in maniera non separata può costituire un potenziale danno per l ambiente e per la salute Tale prodotto può essere restituito al distribut...

Page 16: ...he timer outlet If cleaning of the timer is required remove from mains power and wipe timer with a dry cloth DO NOT IMMERSE TIMER IN WATER OR ANY OTHER LIQUID Heaters and similar appliances should never be left unattended during operation The manufacturer recommends such appliances not be connected to timers Conform to directive 2014 30 CE e 2014 35 CE MK680 WEEKLY PROGRAMMABLE THERMOSTAT INSTRUCT...

Page 17: ...ting symbol 18 Economic Setting symbol 19 TEMPerature Setting symbol 20 COPY feature symbol 21 ROOM Temperature symbol 22 OFF symbol 2 Clock and Feature setting Press and hold the SET button for 3 seconds to enter the Clock and Feature settings Press SELECT button to select tI for Clock St for feature setting and as figure shown below Press SET to enter the selected setting Clock Feature Setting A...

Page 18: ...n to the next step Minute setting Use the setting dial to set Press SELECT back to Year setting Press OK button to save and quit this setting B Feature setting Use SELECT button to choice the Holiday and Heat Cool control setting Ho for Holiday Ht or CL for Heat Cool control setting and as figure shown below Press SET to enter the selected setting Holiday Heat Cool Control ...

Page 19: ...holiday setting running to 0 or to be set to 0 b Heat Cool Control this feature set the system is under Heating or Cooling control and also set the system starting delay enable or disable Use SELECT button to select Heating or Cooling control Ht for Heating and CL for Cooling and as figure shownbelow Heating Control Cooling Control Press SET button to confirm and enter the system starting delay en...

Page 20: ... Temperature OPEN CLOSE 1 C Set Temperature CLOSE OPEN Coolting 1 C Set Temperature CLOSE OPEN 1 C Set Temperature OPEN CLOSE For the starting delay this unit offers an optional outputs starting delay for cooling or heating pump protection If you select starting delay this unit will have a 5 minutes delay before each NO terminal CLOSE operation or NC terminal OPEN operation ...

Page 21: ...rozen 4 Program Setting Press PROG button to enter the program setting procedure A First is the program Mode setting Press SELECT button to select program mode as below description a 7 days programs of a week is different The 7dY appears at the bottom of the display b Programs for Weekdays and Weekend The 5 2 appears at the bottom of the display c Programs for Weekdays Saturday and Sunday The 5 1 ...

Page 22: ... Frozen no dot or Off no dot 3 Turn the setting dial to go forward or backward hour for setting The select hour program will keep the same until use TEMP button to select other setting 4 Press PROG to finish this day program setting and back to above procedure to select next day program for setting 5 For a new day program setting you can use Copy feature to set this day program same as the one jus...

Page 23: ...n 4times to The 7dY appears at the left upper side of the display Press PROG to next step to select the day program for reviewing Press SELECT button to select the day of week shown on left upper of display Press PROG to review the day program Using UP DOWN button to check each hour program setting After reviewing press PROG button to back to the day of program selection Press OK back to normal mo...

Page 24: ...perature Setting Override Turn the setting dial to adjust the current temperature setting This overriding will be continued to the next hour The Temporary Manual Control symbol appears on the display C Temporary Hold the current temperature setting press and hold the HOLD button for 3 seconds to enter Turn the setting dial to set the holding time from 1 to 99 hours Press OK button to save and quit...

Page 25: ...6 Battery low alarm when battery is low the battery low Symbol displays and flashes You need to replace the battery Remark The 2 x AA alkaline batteries life on this unit is about ONE heating or Cooling Season 6 months Please check the low battery symbol monthly 7 Specifications Power Rating 230Vac 50Hz 8A Resistive Load Thermal Rate Measurement Temperature Range 0 C to 35 C Setting Temperature Ra...

Page 26: ...NUAL MK680 MK680 contents TWO parts Control Penal and Switching Base Control Panel Switching Base INSTALL SWITCHING BASE TO WALL 1 You maybe need to drill 2 screw holes on the installation surface as the below diagram ...

Page 27: ...ew out the 2 screws on the terminal cover of switching base The remove the terminal cover 3 Take out the wires Following the wiring label on terminal to screw the wires to it 4 Screw back the terminal cover ...

Page 28: ... screws supplied to screw the switching base onto INSTALL BATTERY AND CONTROL PANEL 1 Install 2 AAA size batteries to the control panel as the symbol on it 2 Take the right and left side of control panel and press it onto switching base Remember always take the right and left side of control panel for installing Do not use UP and BOTTOM side ...

Page 29: ...C to 30 C Power 2 x AAA Alkaline Battery Operated not included DISPOSAL OF THE UNIT Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To...

Page 30: ...Made in China MELCHIONI S p A Via P Colletta 37 Milano Italia Tel 02 57941 www melchioni it www b2b melchioni it ...