SD

1. LCD

2. POWER KEY

3. COLOR PALETTE

4. MODE

5. UNIT

6. MENU

7. MICRO SD

8. MINI USB

10. INFRARED LENS

11. TRIGGER

12. BATTERY COVER

9. VISIBLE CAMERA

 

SETTING UP YOUR THERMAL IMAGER 

INSTALLING THE MICRO SD CARD
Before you begin to use your thermal imaging camera, a microSD card must be inserted. 
A microSD card is a memory device that allows you to store images recorded by your 
thermal imaging camera. Please follow the steps below to insert the microSD card.

PLEASE NOTE: 

You can easily damage the microSD card by improper operation. Please be 

careful when inserting, removing, or handling the microSD card.
On one side of your thermal imaging camera there is 
a rubber plug protecting the microSD slot and the USB 
connector from dust and damage. Please pull it up 
slightly and gently, and turn it 90° clockwise.
1. Insert the microSD card and push it all the way inside  
    the slot until you hear a “click”, the microSD card is  
    now locked in place.  
2. Once the microSD card is installed, place the rubber  
    plug back to secure the area against damage. 

Page   1   

   

SECTION 1: Setting Up your TERMAL IMAGER(TIM) 

Installing the microSD card 

Before you begin to use your TIM, a microSD  card must be inserted.  A 

microSD  card is a  memory device  that allows you to store images, and 

videos recorded by your TIM. There is an 8GB microSD card included in the 

product package.  Please follow the steps below to insert the  microSD 

card. 

1.

 

Please identify the 8GB microSD card, and 

remove it from its package. 

 

 

 

 

 

On one side of your TIM there is a rubber plug 

protecting the microSD slot and the USB 

connector from dust and damage. Please pull it 

up slightly and gently, and turn it 90° 

clockwise. 

 

 

2.

 

Insert the microSD card 

with the narrow side 

towards the slot, and the 

white lettering  facing 

toward the screen. 

Push it all the way 

inside the slot until you 

hear a “

click

”, and the 

microSD card is  now  locked 

in place.  

 

 

 

3.

 

Once the microSD card is installed 

place the  rubber plug back  to 

secure the area against damage. 

 

 

 

microSD 

adapter 

microSD 

memory 

You can easily damage the microSD 

card by improper operation.  

Please be careful when inserting, 

removing, or handling the microSD 

card. 

Rubber 

Plug 

Sensor 

Lens 

Trigger 

Batteries 

Compartment 

microSD 

card slot 

USB Type B 

Connector 

BASIC OPERATION 

1. Power On: Press the POWER   key (2) to power on the unit.
2. Taking a thermal image and temperature: After powering on,  
    simply aim at the measure target with the INFRARED LENS (10)  
    to get the fusion images and temperature immediately.  
    Please make sure the target area is within the field of view.  
    

Note: 

There is a cursor on the screen. The cursor shows the  

    temperature of the object located in the middle of the screen. 
3. Save Images: Press the TRIGGER (11) to save the thermal  
    image to the micro SD card.

4. Power Off: Press the POWER [   ] key (2) for more than 3 sec. to power off the unit. Auto  

    power off time is about 1 minute. (Please see the FUNCTIONS section to learn how to  
    adjust the auto off time.)

FUNCTIONS 

• Display Mode: Press MODE [   ] key (4) to switch the display mode.  
   (Fusion-Thermal-Visual) 

Note:

 Fusion is the default mode. 

• Color Palettes: Press COLOR PALETTE [ 

I

I

] key (3) to select the color palette,  

   (4 selectable color palettes).

O

O

p

p

e

e

r

r

a

a

t

t

i

i

n

n

g

g

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

f

f

o

o

r

r

 

 

T

T

I

I

M

M

0

0

3

3

 

 

T

T

h

h

e

e

r

r

m

m

a

a

l

l

 

 

I

I

m

m

a

a

g

g

e

e

r

r

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

The thermal imager camera can measure from -20~250°C (-4~482°F) and displays the thermal image and temperature. 
Furthermore, thermal images can be saved to a micro SD card. Transferring images to the software is included for image report 
generation from these saved images.

 

 

OPERATION 

1.

 

Power on 
Press Mode Key (

2

) or Trigger (

10

) to power on the unit. 

2.

 

Taking a thermal image and temperature 
After  power  on, simply  aim the thermal  imager  camera  at the  measure target  with  Lens 
(

9

)  and  get  the  thermal  image  and  temperature  immediately.  Please  make  sure  the 

target area is within the field of view. 
Note:  There  are three  cursors  on the  screen. The  cross  sign  shows the temperature of 
the  object  located  in  the  middle  of  the  screen.  Other  two  moving  cursors  indicate  the

 

highest and lowest temperatures in the thermal image. 

3.

 

Save thermal images 
Press Trigger (

10

) to save the thermal image to the micro SD card, press Up Key (

3

) or 

Down Key (

4

) to  show the  saved images. Press Mode  Key (

2

) again  to return to the 

measurement screen.

 

4.

 

Color palettes 
Press Color Palette Key (

6

) to select the color palette (4 selectable color palettes) to view thermal images. 

 

 

 

 

Ironbow 

Rainbow 

High contrast 

Grayscale 

5.

 

C/°F/K 

Press Unit Key (

5

) for  C

°F or K transferred. 

6.

 

Power off 

        Press Mode Key (

2

) for more than 5 sec. to power off the unit. Auto power off time is around 30 sec..

 

 
FUNCTIONS 

Press  Mode  Key  (

2

)  for  scrolling  more  display  functions,  then  press  Up  key  (

3

)  or  Down  key  (

4

)  to  change  the 

functions, then press Trigger (

10

) to confirm it. 

Emissivity 

The default emissivity is 0.95, or select other default emissivity: Matt:0.95Semi-matt:0.8Semi-glossy:0.6
Glossy:0.3 
Select Set value to adjust the emissivity (0.1 to 1 step .01). 

HAL 

You  can  select  Set  Min  temp  or  Set  Max  item  to  adjust  the  High  Alarm  (HAL)  or  Lo  Alarm  (LAL)  limits 
(step .1). 

LAL 

Language 

Selectable Chinese or English

Backlight 

Selectable 5 levels of brightness. 

Set Time 

Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS (hour/minute/second) formats. 

Time stamp 

Turn on Time stamp to save thermal images with real-time stamp.   
Turn off Time stamp to hide date and time on stored thermal images. 

Erase Image 

Select Yes, All image! to clear all stored thermal images. 

Reset 

Select Reset to recover the factory setting data. 

Set parameter 

Select Use Median Value

 

to reduce noise in an image. 

Select No Filter

 

to display real image noise. 

 
STORAGE & CLEANING       

It  should  be  stored  at  room  temperature.  The  sensor  lens  is the most  delicate  part  of the  thermometer.  The  lens  should  be  kept 
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. 
Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.   

 
BATTERIES
 

The thermometer incorporates visual low battery indication as follows: 

 

 

 

‘Battery OK’: measurements 

  are possible 

‘Battery Low’: battery needs to be   

replaced, measurements are still possible 

‘Battery Exhausted’: measurements are 

not possible 

  When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries. 

Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction. 

  Dispose of used battery promptly and keep away from children. 

 

SPECIFICATION 

Thermal Image Resolution 

32*31 

Measurement Range 

-20~250°C (-4~482°F) 

Accuracy (Tamb=20~26°C) 

2% of reading, or 2°C(4°F) whichever is greater 

Thermal Sensitivity 

0.1°C 

Frame Rate 

9Hz 

Field of View 

40*40 deg 

Emissivity Range 

0.95 default – adjustable 0.1 to 1 step .01 

Focus 

Focus free 

LCD (inch) 

2.8 

LCD Type 

Color 

Image Storage 

Stores up to 60000 images/GB, 

Bitmap (BMP) file format.

 

Memory Type 

Support 8G micro SD card 

Sensor Filter (um) 

8~14um 

Interface 

USB 

Battery Type 

AA*4 

Battery Life (hr)(backlit) 

6   

Dimensions 

94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch) 

Weight 

411 grams(14.5 oz) including batteries (AA*4pcs) 

 

EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per 

meter, but the performance of the instrument will not be permanently affected.

 

* IP54 Splash Proof 

 

IRONBOW

RAINBOW

HIGH CONTRAST

GRAY SCALE

   Press COLOR PALETTE [ 

I

I

] key (3) for 3 seconds to enter the fixed range mode (the icon  

   of the fixed range mode is   ) After that, the user can fix the range by pressing the  
   TRIGGER (11) while scanning.
• °C/°F: Press UNIT [ 

˚C

˚F

 ] key (5) to convert temperature unit. 

• Display Functions: Press MENU [   ] key (6) for the display functions featured in the  
   chart below, then press the COLOR PALETTE [ 

I

I

] key (3) or MODE [   ] key (4) to  

   select the function. Press the UNIT [ 

˚C

˚F

 ] key (5) to set the function and then press the  

   TRIGGER (11) to select or confirm it.

 Cursor Measurement

 The cursor shows the temperature of the object located in 

the middle of the screen.

 Hide the cursor measurement

 Brightness

3-level brightness:   Low     Medium     High

3

 Fusion Ratio

Fusion images by 3-level ratio of combining thermal and 
visual images.

1

 > 

2

 > 

3

 (

3

 is the default mode)