background image

OWNERS MANUAL

INSTALLATION, OPERATION & MAINTENANCE

RANGES & GRIDDLE/BROILER

35 Garvey Street 

l

 Everett 

l

 MA 

l

 02149

Tel: (617) 387-4100 

l

 Fax: (617) 387-4456

Outside Fax: 1-800-227-2659

E-Mail: [email protected] 

l

 Website: www.mfii.com

Form Number: S-2551
11/04

Printed in U.S.A.

CAUTION:

Instruction to be followed in the event the user smells gas shall be posted 
in  a  pominent  location.  This  informantion  shall  be  obtained  by  consulting 
the local gas supplier.

WARNING:

Improper installation, adjustment, 

alteration, service or maintenance can 

cause damage, injury or death. Read the 

installation, operating & maintenance 

instructions thoroughly before installing or 

servicing the equipment.

FOR YOUR SAFETY:

Do not store or use gasoline or other 

flammable vapors or liquids in the vicinity 

of this or any other appliance.

MODELS:

   

m

 MF-R4

m

 MF-R6

m

 MF-R8

m

 MF-R10

COVERING:

   

- INSTALLATION
- OPERATION
- MAINTENANCE
- PARTS & SERVICE

RAISED GRIDDLES:

m

 MF-RG12-2

m

 MF-RG12-4

m

 MF-RG12-6

m

 MF-RG12-8

m

 MF-RG24

m

 MF-RG24-2

m

 MF-RG24-4

m

 MF-RG24-6

m

 MF-RG36-4

Summary of Contents for MF-R10

Page 1: ...d by consulting the local gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause damage injury or death Read the installation operating maintenance instructions thoroughly before installing or servicing the equipment FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance MODELS m MF...

Page 2: ...pected crafted carefully by skilled personnel before leaving factory The transportation company assumes full responsibility for safe delivery upon acceptance of this equipment If shipment arrives damaged 1 Visible loss or damage Note on freight bill or express delivery and have signed by the person making delivery 2 File claim or damages immediately Regardless of 3the extent of damages 3 Concealed...

Page 3: ... the appliance warranty m The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess if 0 5 PSI 0 04 kg cm2 m The appliance must be isolated from gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at tes...

Page 4: ...the incoming service line for safe and efficient operation since service pressures may fluctuate on local demand A pressure regulator is packed inside every Market Forge range Failure to install the pressure regulator will void the appliance warranty The regulators supplied along with Tri star ranges will have 3 4 inlet outlet openings and are adjusted at the factory for 5 WC natural gas orlO WC p...

Page 5: ...ssary on installation to meet local conditions low gas characteristics correct possible problems caused by rough handling or vibration during shipment and are to be performed only by qualified service personnel These adjustments are the responsibility ofthe customer and or dealer and are not covered by our warranty Check all gas connections for leaks with a soapy water solution before lighting any...

Page 6: ... complete shutdown turn all burner valves pilot valves and thermostats to the off position Turn shut offvalve BEFORE FIRST USE Griddles m Clean the griddle surface thoroughly with hot soapy water remove to protective oil coating applied at the factory m Rinse with a mixture of cup vinegar to one quart water m Spread unsalted solid shortening or liquid frying compound evenly over the entire griddle...

Page 7: ...h a nylon griddle scrapper Be very careful about scratching the porcelain mish on the oven liner panels m Wash all the above with hot soapy water then reassemble Baked on spills may be loosened and stubborn stains removed with ordinary household ammonia and scrubbing with a nylon pad in a cold oven only Do not allow spray type oven cleaners to come into contact with the temperature probe in the ov...

Page 8: ...d MF G24 6 Option 1 MF G36 4 Option 2 MF G48 2 Option 3 MF G60 Option 4 10 Burners 24 Griddle 6 Burners 36 Griddle 4 Burners 48 Griddle 2 Burners 60 Griddle No Burners 420 000 320 000 270 000 220 000 170 000 995 lbs 1100 lbs 1150 lbs 1160 lbs 1175 lbs 1 30 1 20 Oven Base 1 30 1 20 Oven Base 1 30 1 20 Oven Base 1 30 1 20 Oven Base 1 30 1 20 Oven Base Top Base Total BTU Ship Weight MF R10 Top Config...

Page 9: ...FOLD PIPE PILOT BURNER ASSY COMPLETE FRONT AND BACK PILOT VALVE 1 8 NOT X 3 16 CC X 90O FERRULE 3 16 CC COMPRESSION FITTING 3 16 CC 24 VALVE COVER 36 VALVE COVER 48 VALVE COVER 60 VALVE COVER 72 VALVE COVER 30 OVEN DOOR ASSY 20 OVEN DOOR ASSY 30 OVEN DOOR HANDLE 20 OVEN DOOR HANDLE LOCATION OF MARKET FORGE NAME PLATE 30 KICK PLATE 20 KICK PLATE 30 OVEN BOTTOM 20 OVEN BOTTOM 30 OVEN RACK 20 OVEN RA...

Page 10: ... LANDING LEGDE 36 LANDING LEGDE 48 LANDING LEGDE 60 LANDING LEGDE 72 LANDING LEGDE REGULATOR NATURAL USED ON 24 36 REGULATOR L P USED ON 24 36 REGULATOR NATURAL HIGH CAPACITY USED ON 48 60 72 REGULATOR L P HIGH CAPACITY USED ON 48 60 72 HI SHELF SUPPORT CHANNEL R H HI SHELF SUPPORT CHANNEL L H 24 HI SHELF FRONT PANEL 36 HI SHELF FRONT PANEL 48 HI SHELF FRONT PANEL 60 HI SHELF FRONT PANEL 72 HI SHE...

Page 11: ...9 RANGE OVEN ILLUSTRATED PARTS LIST CONT ...

Page 12: ...10 RANGE GRIDDLE BROILER ILLUSTRATED PARTS LIST CONT ...

Reviews: