background image

1

Model #s

2

K00339

40,000 gals (151,417 

liters) chlorine taste 

and odor reduction

AR-40000

1

K00339

20,000 gals (75,708 

liters) chlorine taste 

and odor reduction

AR-20000

1

K00338

10,000 gals (37,854 

liters) chlorine taste 

and odor reduction

AR-10000

1

K00337

Prefilter

AR-Pre

Prefix denotes brand

Description

Replacement

Qty

Suffix denotes claim

Cartridge

Summary of Contents for ArcticPure AR-10000

Page 1: ...ction AR 40000 1 K00339 20 000 gals 75 708 liters chlorine taste and odor reduction AR 20000 1 K00338 10 000 gals 37 854 liters chlorine taste and odor reduction AR 10000 1 K00337 Prefilter AR Pre Prefix denotes brand Description Replacement Qty Suffix denotes claim Cartridge ...

Page 2: ... AR 40000 AR 20000 AR 10000 AR Pre Ice Machine Model Under counter Cubers QC700 Q800 X X Arctic Pure Filtration Technologies Chlorine Taste and Odor Reduction Activated Carbon block Adsorbs contaminants are retained on the surface of the media Large pores within the carbon provide maximum surface area Absorbs contaminants physically migrate into the carbon media Catalytic Action contaminants chemi...

Page 3: ...ns 20 grams of Siliphos AR 20000 contains 40 grams of Siliphos AR 40000 contains 80 grams of Siliphos Siliphos location in cartridge Arctic Pure Products AR Pre Prefilter 5 micron particle reduction Optional for areas with heavy dirt load Reduces short life on finer downstream filters Replacement cartridge is K00337 ...

Page 4: ...0000 Chlorine taste and odor reduction 1 0 micron particle reduction Capacity 10 000 gals 37 854 liters Flow Rate 0 75 gpm 2 84 lpm Replacement cartridge is K00338 NOTE Works with Copper or Polyethylene tubing AR 1000 Dimensions ...

Page 5: ... and odor reduction 1 0 micron particle reduction Extended length for extra capacity Capacity 20 000 gallons 75 708 liters Flow Rate 0 75 gpm 2 84 lpm Replacement cartridge is K00339 NOTE Works with Copper or Polyethylene tubing AR 2000 Dimensions ...

Page 6: ...Physical Attributes AR Pre AR 10000 Vent hole with tubing relieves water pressure during cartridge change out Built in shut off valve in the head allows cartridge changeout on the fly no need to turn the water off to the machine 3 8 John Guest inlet outlets with optional 3 8 stainless fittings provide quick and easy installation Encapsulated cartridge reduces outside contamination Sanitary Quick C...

Page 7: ...uick Change design assures continuance of filter specifications AR 40000 Powder coated aluminum cover is durable and corrosion resistant Built in valve in head allows easy cartridge changeouts on the fly no need to turn the water off to the machine Built in vent hole and tubing guide depressurized water to drain during changeout 3 8 John Guest inlet outlet ports with optional 3 8 stainless fitting...

Page 8: ... Outlet Fitting Dual Inlet Lines Dual Outlet Lines Vent Lines Why This Design Protects the specification Exclusive replacement cartridge design Prevents use of incorrect replacement cartridges Systems cannot function without cartridges non bypassable Patent protected interconnect ...

Page 9: ...ts the water line with 1 4 turn of the cartridge No external shut off valves are required Ramped Cartridge Interconnect The ramped cartridge interconnect engages and disengages the cartridge o rings completely from the head with a 1 4 turn Provides for effortless cartridge change outs ...

Page 10: ... of the AR 10000 and AR 20000 Systems Locate position to mount filter system Be sure to leave 2 inches under the filter cartridges to allow for cartridge change out Mark mounting holes Drill mounting holes Install mounting screws and mount filter head using key hole slots in mounting bracket Tighten mounting screws ...

Page 11: ... hangs evenly Place the bottom of mounting bracket on the leveled line Mark top and bottom mounting holes Drill top and bottom mounting holes At least 2 gap for all cartridges Installation of the AR 40000 System Install bottom mounting screws Slide key hole slots down onto the screws Install top mounting screws Tighten all 4 mounting screws Install manifold cover using the 4 sheet metal screws pro...

Page 12: ...h quality exact size and roundness and has no nicks or scratches Tubing end must be clean and square Use tubing cutter or sharp razor knife if necessary Push tubing into the fitting as far as it will go then pull back to seat o ring Stainless threaded fittings are provided as optional connections Water Connections for the AR 10000 AR 20000 and AR 40000 Filter Systems Correct End Cut Incorrect End ...

Page 13: ...head assembly Rotate 1 4 turn to the right to secure Product label will be facing front NOTE Flush cartridge for 2 minutes to remove trapped air and carbon fines AR Pre AR 10000 and AR 20000 AR 40000 Installation of filter cartridges Installation of AR Pre Use the following procedure to install the AR Pre when your AR 10000 AR 20000 or AR 40000 filter system has been installed Shut off the incomin...

Page 14: ...ine 4 5 from the center of the first mounting screw Mark second hole 1 5 from the first hole mark For installation to an AR 40000 system Mark the first hole for the AR Pre on the level line 5 5 from the center of the lower left mounting screw Mark second hole 1 5 from the first hole mark Installation of AR Pre Drill the mounting holes and insert mounting screws Insert precut copper tubing part 760...

Page 15: ...n incoming water supply Check for leaks NOTE Flush cartridge for 2 minutes to remove trapped air and carbon fines Setting the pressure gauge Rotate the red follower needle clockwise until the follower contacts the black pressure needle on the low side The red follower needle will now record the lowest water flow pressure when the filter system is being used ...

Page 16: ...l label that can be detached This label must be adhered to the enclosed warranty card for submittal Fill out the appropriate information and place on the warranty card as shown Return to Manitowoc Routine maintenance Cartridge change out Water leak repair ...

Page 17: ... the water and hard scale formation may be accelerated This is due to the ability of calcium and magnesium ions adhere to the sediment particles Water filter cartridges need to be changed for one or more of the following reasons Recommended filter change out Every 6 months or When the water flow through the cartridge is below 20 psi 137 9 kPa It is recommended that all filter cartridges in the sys...

Page 18: ...e See sales list when replacement is required Lubricate o rings with food grade lubricant With the product label facing to the left insert the cartridge into the filter head Rotate 1 4 turn to the right to secure The label should be facing forward Rotate turn to left to remove Rotate turn to right to install Troubleshooting A leak may occur because of defective tubing To fix Turn off incoming wate...

Page 19: ...ugged Replace filter cartridges Low water pressure to Repair water supply filter system to filters Water leak on water inlet outlet Water line ends are damaged Trim water line to remove damaged area O Ring in filter head is Replace O Ring damaged Water leak between head Damaged O ring on Replace O ring and filter cartridge filter cartridge Low water flow through filter system below 20 psi 137 9 kP...

Reviews: