KM228 Issue10 © 2017 

 

 

INSTRUCTION MANUAL 

GENERAL INFORMATION 

K7 / KR MINI-LUBE 

Please  take  a  few  moments  to  read  through  this  manual 
before  operating  your  new  Mini-Lube.  If  you  experience 
any  problem  with  the  product,  refer  to  the  Maintenance 
and Trouble Shooting sections of this manual. 

ASSEMBLY 

2) Insert follower into the grease pail with the follower boss 
facing  upwards.  Push  down  firmly  until  grease  emerges 
through the boss. 

3) Push the pump tube through the follower boss until the 
lid  sits  on  the  rim  of  the  container.    Hand  tighten  the  3 
thumb screws evenly under container rim. 

If the unit fails to prime

, bump the container base several 

times on a solid surface. 

OPERATING INSTRUCTIONS 

After  completing  the  assembly  instructions  as  described 
above, your Mini-Lube is now ready for use. 

MAINTENANCE 

The  Macnaught  K7/KR  Mini-Lube  is  a  completely 
portable  high  pressure  manual  greasing  system, 
supplied  with  spring  loaded  pump,  lid,  rubber-edged 
follower plate, 1.5 metres of special Macnaught grease 
hose, and unique KR  Pressurite (High pressure / High 
Volume) grease gun. 

Please  read  and  retain  this  instruction  manual  to 
assist  you  in  the  operation  and  maintenance  of  this 
quality product. 

1)Remove the follower plate from the pump tube

4)  To  prime,  push  the  rod  cap  down  several  times  with 
your foot. When the hose is full of grease, the rod cap will 
stay down. 

5)  Squeeze  the  KR  gun  handle  and  hold  closed  to  bleed 
air out of the system. When fully bled, container grease will 
emerge from the gun end. 

Note:

  Grease  must  travel  through  the  entire  length  of  the 

hose.  It  may  be  necessary  to  repeat  step  4  to  fully  bleed 
the system. 

When greasing, the rod cap will rise slowly. When the rod 
is  fully  up  and  the  gun  loses  pressure,  push  the  rod  cap 
down  once  or  twice  to  re-prime  the  pump  and  continue 
greasing. 

Each pump prime will provide sufficient grease for up to 30 
shots of grease. 

The  gun  is  normally  operated  on  the  HI-VOLUME  switch 
position.  Should  high  pressure  be  required,  simply  push 
the switch on the gun to the HI-PRESSURE position. 

Note:

  To  remove  air  bubbles  bump  the  container  base 

several times on a solid surface. 

REFILLING CONTAINERS 

For  easy  refilling of containers,  use the  Macnaught  Model 

J3 grease pump

.

 

Should  the  strainer  require  cleaning,  undo  the  nut  at  the 
base  of  the  pump  spring  with  a  suitable  spanner,  remove 
assembly,  lever  off  strainer  cover  and  remove  strainer  as 
illustrated.  Clean  all  parts,  replace  any  damaged  or  worn 
components before reassembly. 

If replacing hose assembly only use a genuine  
Macnaught  hose,  failure  to  do  so  may  damage  the 
pump. 

KR PRESSURITE GUN FEATURES 

Operation on the  
High Volume Setting 

Operation on the  
High Pressure Setting 

Introduction 

 CAUTION 

GENERAL INSTRUCTIONS 

When  the  KR  gun  has  been  serviced  and  the  trouble  is 
found to have been caused by dirt in the valves, the pump 
unit should also be cleaned out . 

Includes m odels

K7-01, K7-03, K7-13
K7-14, K7-17, K7-23

K7-23-01, K7-24, K7-29-04

K7-36, K7-52, K7-55

K7-67-01, K7-67-05, K7-67G

K7-75

Summary of Contents for K7/KR MINI-LUBE Series

Page 1: ...old closed to bleed air out of the system When fully bled container grease will emerge from the gun end Note Grease must travel through the entire length of the hose It may be necessary to repeat step...

Page 2: ...lean surfaces b Replace seal washer 8 TROUBLE CAUSE REMEDY Coupler leaks a Dirt under the outlet ball 23 seat a Remove the extension tube 28 spring keeper screw 21 spring 22 and ball 23 Note There is...

Page 3: ...cessaire de r p ter plusieurs fois l tape 4 pour purger compl tement le syst me Si l appareil ne s amorce pas frapper le fond du r cipient plusieurs reprises sur une surface solide Une fois l assembl...

Page 4: ...e b Remplacer la rondelle d tanch it 8 La graisse fuit sous l crou de serrage 7 PANNE CAUSE ACTION CORRECTIVE Le coupleur fuit a Salet sous le si ge de la bille de sorti 23 a D poser le tube prolonga...

Page 5: ...Schritt 4 wiederholen damit die Luft das System vollst ndig verl sst Falls das Ger t nicht ansaugt schlagen Sie den Boden des Beh lters einige Male auf eine feste Oberfl che GEBRAUCHSANWEISUNG Wenn Si...

Page 6: ...utter 7 aus PROBLEM URSACHE L SUNG a Dreck unter dem Sitz der Auslasskugel 23 a Verl ngerungsrohr 28 Federschraube 21 Feder 22 und Kugel 23 entfernen Hinweis Das Verbindungsst ck selbst ist nicht defe...

Page 7: ...urgar totalmente el sistema Si la unidad no se ceba golpee varias veces la base del recipiente sobre una superficie s lida INSTRUCCIONES DE USO Una vez completadas las instrucciones de montaje descrit...

Page 8: ...la tuerca de fijaci n 7 PISTOLA DE GRASA KR PRESSURITE PROBLEMA CAUSA SOLUCI N P rdidas en el acoplador a Suciedad debajo del asiento del rodamiento exterior 23 Nota El acoplador en s no presenta prob...

Page 9: ...KM228 Issue10 2017 9 K7 KR Macnaught K7 KR Macnaught 1 5 m KR Pressurite 1 2 2 Fig 1 Fig 2 3 3 4 5 KR 4 1 2 1 30 HI VOLUME HI PRESSURE Macnaught J2 Macnaught KR PRESSURITE High Volume High Pressure KR...

Page 10: ...KM228 Issue10 2017 10 K7 7 11 7 a 28 10 b o 27 a i b c 21 a b 13 o 6 5 o 14 a 7 b 8 a 7 28 10 b o 27 a i 22 ii o 23 b a NLGI No2 c b 7 11 13 7 10 7 2 29 29 o 6 5 9 10 2 1 11 o 14 a b 8 ii o 23...

Page 11: ...KM228 Issue10 2017 11 KR PRESSURITE G a 23 b 3 23 Glyd a b 25 26 c 3 8 a 9 b 10 16 o 15 a 18 32 a 2 4 b c 22 a 28 21 22 23 2 24 29 o b a b 25 26 c a 16 9 o 14 13 12 b a KR 1K b NLGI No 2 c A a...

Page 12: ...ainer 14 1 A B O ring BS240 15 1 order K7001 pump only A Strainer container 16 1 Lid base 17 3 for models K7 01 K7 24 only Gutter bolt 18 1 See note below Pump tube 19 1 B Ball retainer 20 1 B 9 16 Ba...

Page 13: ...1 Operating Plunger Control 11 2 Cap Socket 1 2 X3 16 w hit 12 1 KR12s A Spring inlet check 13 1 A 5 16 Ball Inlet 14 2 A O ring Seal Body BS013 15 1 A O ring Plunger Control BS008 16 1 Control Body A...

Page 14: ...KM228 Issue10 2017 14 Notes...

Page 15: ...KM228 Issue10 2017 15 Notes...

Page 16: ...pistolet graisse KR est compatible avec les syst mes de graissage Macnaught mod les K4 et K7 Il est recommand d utiliser le pistolet graisse KR avec des graisses d une consistance allant jusqu la cla...

Reviews: