Summary of Contents for 87D

Page 1: ...Owners Manual Parts List for 87D 87 Double Auger Snowblower M K Martin Enterprise 3950 Steffler Rd Elmira Ont N3B 2Z3 519 tel 664 2752 fax 664 3695 E mail sales mkmartin ca Snowblowers rev 12 1 ...

Page 2: ...y 4 Decal Location 5 Sign Off Form 6 Assembly Information 7 Operation 8 Installing manual Chute Rotator 9 Installing Hydraulic Chute Rotator 10 Main Parts 11 Chute Rotator Parts 12 Gearbox Parts 13 Comer PTO Parts 14 Canimex PTO Instructions 15 Bolt Torque 16 Maintenance Lubrication Storage Notes 1 ...

Page 3: ...pany s liability shall be limited exclusively to replacing or repairing without charge at it s factory or elsewhere at it s discretion any material or workmanship defects which becomes apparent within one year from the date of purchase The company will have no liability for damages of any kind The buyer by the acceptance of the equipment will assume all liability for any damages which may result f...

Page 4: ...in this book Caution Indicates a potentially hazardous situation that may result injury Warning Indicates a potentially hazardous situation that could result in serious injury or death Danger Indicates a hazardous situation that needs to be avoided It is you the operator that needs to be aware of these dangers If you have any questions not answered in this manual please contact your dealer or M K ...

Page 5: ...fety instructions with all users annually This equipment should not be operated by children or those unfamiliar with the operation of the Meteor Blower Do not allow persons to operate this machine until they have read this manual and or were instructed by a qualified person Do not paint over remove or deface any safety signs or warning decals on the Meteor Blower Observe all safety signs and pract...

Page 6: ...rate this equipment until such information has been reviewed annually review this information before the season start up Make these reviews of SAFETY and OPERATION annually as a standard practice for all your equipment We feel that an untrained operator is unqualified to operate this machine A sign off sheet is provided for your record keeping to show that all personnel who will be working with th...

Page 7: ...hold the Plastic ring on the blower and place the base of the chute on top of the plastic ring Note Plastic Ring can be lightly coated with grease at this time Take two 5 8 bolts and drop them down through the chute clamp turn the clamp upside down while holding the bolts in the holes place a 5 8 wave washer on the bolts then a 5 8 bearing and finish off with a second 5 8 wave washer Turn the clam...

Page 8: ...ts supplied and Locknuts Insert the bottom end of the worm gear 3 into the Tail Bracket slide the top bracket 2 into place and secure with bolts 7 Install spring pin 5 Slide Crank 4 into tube as shown and secure with the Set Screws 6 Please note When the blower is raised the Crank will be closer to the tractor and could damage the cab or cause injury to the operator 1 2 3 4 5 6 7 7 Bolts 2 pc 3 8x...

Page 9: ...ld is mounted with 4 5 16 bolts as shown When installing the hydraulic elbows turn them in not more than 4 rounds then tighten the jamnut to secure the elbow in the direction that you want the hoses to go as shown The relief valve is factory preset to 900 PSI Route the hoses and tie them to the top A frame support away from moving equipment Ensure that the hoses do not get too tight or rub on the ...

Page 10: ...any filings from the surfaces and slide the shaft together to be sure that it slides freely 6 Make sure the plastic shield is free to rotate on the shaft before installing on the machine 7 Reinstall the PTO on the blower and fasten it to the tractor pushing the spring loaded pin in and sliding the yoke onto the tractor spline until the pin snaps into place 8 Next lift the 3PH arms to the highest p...

Page 11: ...nt to shorten the top 3PH link to tilt the blower back so it will not dig into the loose gravel In colder climates where the bare ground is frozen during most of the winter the blower can be adjusted to scrape the snow off the frozen drive after freeze up In areas where the gravel is not frozen most of the time we have skid shoes available to bolt on the end plates to raise the blower a few inches...

Page 12: ...y 519 8711505D 1 2 Fan 519 87115208 1 3 Hexbolt 5 8x1 1 2 2 c w lw OL 1 4 Chute 519 87116009 1 5 Deflector 519 87115608 1 6 Hinge Pin 519 87115808 1 7 Cotter Pin 1 8x1 OL 1 8 Hair Pin 5 32 OL 2 9 Adjuster 519 871155 1 10 Adjuster Pin 519 871154 1 11 Antifriction Ring 519 871161 1 11 ...

Page 13: ... 872029 1 27 Cross Shaft 519 871184 1 28 Auger Shear Sprocket 519 873025 1 29 Flangette 519 871174 2 30 Bearing 519 871175 1 31 5 16x1 1 4 c w ln OL 1 32 Hexbolt 3 8x1 c w n lw OL 3 33 Cross Shaft Shield 519 871055D 1 34 Hexbolt 3 8x1 c w n lw OL 4 35 Fan Key 3 8 sq x 3 5 8 519 871062 1 36 Gearbox 519 871186 1 37 PTO Assembly 519 871187 1 38 Hexbolt 1 2x1 c w lw OL 8 39 Hitch Pin 519 8720965 2 40 ...

Page 14: ... Description Part No Req 1 Crank Tail Bracket 519 87719109 1 2 Upper Hand Crank Bracket 519 87109009 1 3 Crank 519 68109109 4 Crank Worm 519 68719209 1 5 5 16x1 1 2 Spring Pin OL 1 6 5 16x3 4 sq h Setscrew OL 2 7 5 8 11x2 1 2 Bolt c w ln OL 2 8 3 8x1 1 4 Bolt c w n lw OL 2 13 ...

Page 15: ...d OL 2 4 Crossover Relief Valve 519 511705 1 5 Socket Head Cap Screw 5 16x1 1 2 OL 4 6 Small Gear 519 511706 1 7 Right Shield 519 87170709 1 8 Left Shield 519 87170809 1 9 Elbow 519 9515 10 6 2 10 Hose 519 871709 2 11 Hexbolt 3 8x1 c w lw OL 4 12 Hexbolt 1 2 20x2 UNF c w n lw OL 2 13 Hexbolt 5 16x1 1 2 c w lw OL 2 14 Hexbolt 5 16x1 c w n lw Ol 2 14 ...

Page 16: ...2675000 1 7 Plug 519 86500006 2 8 Cover 519 02671300 1 9 Bolt M10 x 14 519 81101031 4 10 Shim 79 7 519 01107500 1 11 Shaft Thru 519 02674221 1 12 Snap Ring 40 UN17435 519 85100029 1 13 Bearing 30207 519 80900026 1 14 Snap Ring 72 17437 519 85200131 1 15 Spacer 519 02677100 1 16 Bearing 6207 519 80100025 1 17 Snap Ring UN17435 519 85100005 1 18 Double Lip Seal 35x72x10 519 87100152 1 19 Shaft 519 0...

Page 17: ...aining Collar of Inner Tube 8180 015 289 11 38 Safety Chain 180 016 025 2 40 Complete Guard with Instruction Manual 142 250 372 7521 1 61 Special Grease Nipple 8180 012 418 3 71 Bolt Nut M10x55 cl 8 8 165 000 511 1 72 Grease Fitting 190 000 020 1 73 Bolt Nut M12x1 25x70 cl 8 8 165 000 525 2 200 Collar Kit for 1 3 8 Yoke 165 000 628 1 Danger Label for Outer Tube 190 000 216 1 Danger Label for Outer...

Page 18: ...PTO Installation Instructions for Snowblower 17 ...

Page 19: ... very high too large angles at PTO universal joints will result and the life of the universal joints will be shortened dramatically P T O Shaft angles PTO shafts are made to transmit power with angle at universal joints However these angles should be kept to a minimum Larger angles shorten the life of PTO Take for example a snowblower sold for a tractor horse power of 60 75 HP which would be attac...

Page 20: ...onal gearbox is also available that can be mounted on the existing snowblower gearbox which increases the input shaft height reducing the angle at PTO joints This Gearbox has an input speed of 1000RPM wich greatly increases PTO capacity Non Equal Angles at PTO Joints Equal Angles At PTO Joints To Avoid Recommended Angles at each end of PTO A popular habit is to change snowblower angle in order to ...

Page 21: ...pacity to shock load These shafts cannot be broken under normal loads However undesirable objects may enter the fan and either bend or break the gearbox shaft It is understood that the gearbox cannot be built to resist every possable overload and consequently gearbox fan shafts will not be replaced under warranty Therefore the user of the snowblower must be very careful Maximum length of PTO shaft...

Page 22: ...Effective PTO Drive Shaft Maintenance 21 ...

Page 23: ... shafts may have a locking collar Damages Causes and corrective actions will still be similar Avoidable Damage Possible Causes Corrective Actions Deformed Yoke Excessive shaft length Axial load too high Excessive working angle and torque Shorten shaft length cut both telescopic tubes as well as shield remove burrs Replace defective yokes Clean and grease telescopic tubes Replace both tubes if nece...

Page 24: ...lity between shaft and working conditions Carefully follow greasing instructions Replace defective cross bearings Note Cross bearings must be greased every 8 working hours Avoidable Damages Possible Causes Corrective Actions Telescopic tube failure or twisting Excessive torque or shock load Short tube engagement overlap Use appropriate safety device Change to a larger PTO size Replace the PTO driv...

Page 25: ...allow for maximum angularity Replace defective parts Guard cone damaged Guard cone in contact with implement or tractor Excessive angularity Eliminate interference between guard cone and any part of implement or tractor Avoid excessive angles Replace damaged guard cone Guard tubes damaged deformed and split at one side Guards are in contact with tractor or implement Guard tube overlap too short or...

Page 26: ... 9 12 12 17 5 16 10 13 19 25 27 36 3 8 20 27 33 45 45 63 7 16 30 41 53 72 75 100 1 2 45 61 80 110 115 155 5 8 95 128 160 215 220 305 3 4 165 225 290 390 400 540 1 225 345 630 850 970 1320 Allen head cap screws are similar to SAE 8 quality These torques are for a reference only Not all these sizes and grades are necessarily used in this machine Bolts that are used as a pivot or hinge have to be use...

Page 27: ...paringly every 50 hours By using too much grease you will push the seals off the bearing PTO Shaft grease every 10 hours Pull apart and apply grease to he sliding members Grease the yoke bearings at this time as well Auger Chain apply oil on a regular basis especially after using the snowblower Storing the Meteor Snowblower in the off season At the end of the season lubricate the Bearings PTO shaf...