Page 1: ... Intelligent Paging Station M 6588 User s Manual Thank you for using our public address system Please read this User Manual carefully to make better use of this equipment LY International Electronics Co Ltd Http www lyintlcorp com ...

Page 2: ...cation description and product technical parameters with respect to the network public address and paging station equipment Users should read this Manual carefully before any connection and use and should operate in accordance with instructions in the Manual Messages following this icon on the rear panel include important information needing attentions so please use or operate the equipment in acc...

Page 3: ...nnect the power supply when the equipment is connected to any other equipment Please turn the volume down to the minimum level before switching on or powering off the equipment Symbols of on any terminal in the equipment indicate that such terminal is live and dangerous and any connecting operation should be done by trained personnel In case any abnormal condition is detected If the power wire is ...

Page 4: ...ower on 7 4 2 Main interface 8 4 2 1 Display of time and network connection status 8 4 2 2 Display of zone status information 9 4 2 3 Zone paging operation 9 4 2 4 Group calling operation 9 4 2 5 Pre listen a program 10 4 2 6 Zone broadcast 11 4 2 7 Other operations 14 4 3 System Setup 15 4 3 1 Group setup 15 4 3 2 Network Setup 17 4 3 3 Time Setup 17 4 3 4 Backlight on time 17 4 3 5 Microphone Se...

Page 5: ... features Support 100 10Mbps self adaption TCP IP network transmission protocol 7 inch true color LCD display graphic interface and touch screen operation Desktop type High fidelity and handheld dynamic microphone Multiple level indication function Quick paging with manual shortcut keys Built in 3W monitoring loudspeaker for easy pre listening program and intercom use With 1 channel line input ext...

Page 6: ...k transmission communication mode 2 Appearance 2 1 Front view 1 Microphone head Please do NOT hit the microphone head when the equipment is in use 2 Microphone On Off indicating ring Indicating LED When the microphone is on the indicating light will be on The LED will be turned on as the microphone On Off indicating light is on for calling all zones The microphone head indicting ring will be on bu...

Page 7: ...be on when any terminal is called 10 Paging button It is used to realize paging function for all zones 2 2 Rear view 1 On Off switch When the button at 1 position is pressed down the system is powered on while when the button at 1 position is ejected the system is powered off 2 AC220V Power input wire 3 Network interface It is used to connect to network switches 4 HDMI output interface Preserved 5...

Page 8: ...ntroller for information about connection of the whole system The figure above is only for demonstration please refer to the connecting diagrams at the application site for information about actual connection Connection in the system can only be realized via a network switch and an address should be configured in order to communicate with the controller and to paging the zones 以 太 网 Other devices ...

Page 9: ...r use to connect amplifiers and speakers to realize amplification at local places of the Paging Station The user friendly design can meet the needs of large output power and multiple audio sources at the local places of terminals the Paging Station also provides auxiliary audio input interface for connecting to players The connection of local interfaces is as follows CD player Monitoring headphone...

Page 10: ...the power switch on rear panel to turn on the system After the system is turned on it enters the initialization status and the message System is starting please wait on screen of the paging station During this process the system will load the previous operation information of the paging station It may take about 25 seconds to complete this process and display the following interface ...

Page 11: ...ain interface include Status operation of zones display of zone status information zone paging group paging pre listening programs system setup exit button 4 2 Main interface 4 2 1 Display of time and network connection status As shown above the status bar on the main interface shows the current date and time information as well as the network connection status Display of current date and time Dis...

Page 12: ...d operation 4 2 3 Zone paging operation To call paging a zone In the first step touch the Zone Call icon on the upper right side of the main interface then touch the zone to be called a selected zone is surrounded by white box and then touch the Call button to start the calling The message Calling will be displayed on the zone which is being called Press the Stop button to stop the calling and the...

Page 13: ...re shown above the directory shown on the left part indicates the built in programs on the network controller and external audio sources connected to the controller Touch a directory for instance touch the Courtesy the songs in such directory will be displayed on the Song box on the right part Touch the song to be played and then touch the button to start playing and touch the button to stop the p...

Page 14: ...nterface Play a program courtesy program calisthenic program and other background music are built in audio sources of the network controller and the external audio sources include external audio equipment connected to the controller such as a CD player or a MP3 player If no external audio source device is connected to the network controller then no equipment output is displayed Therefore please ma...

Page 15: ...ress System 12 Then click Zone Call to choose the zone you want to broadcast or touch Group Call to choose groups Then enter the interface above again to choose the music or program you want to play Choose zone or group ...

Page 16: ...Network Public Address System 13 If no zone is selected you will see the following interface Click to play the music or program The interface will show Playing ...

Page 17: ...cel the selection of a zone Bell alarm button is used to broadcast a bell alarm before calling Page Up and Page Down buttons are used to display the previous and the next page of zone for query operation On the main interface the icon is used to exit the main interface and return to the password input interface ...

Page 18: ...ouch screen of the current paging station 4 3 1 Group setup On the System Setup interface touch the Group Setup icon to enter the group setup interface The zone box is displayed on the right part of the interface and the group box is displayed on the left part The editing and operating buttons are listed on the bottom of the boxes and to the right of the box there are the selection buttons Before ...

Page 19: ...the Arrow pointing to the left box then the zone will be moved to the left box which means that the zone has been added to such group On the zone allocation interface button can be used to add or remove one single zone in the group button can be used to add or remove all zones in the group button can be used to return to the previous interface buttons can be used to switch to the previous page or ...

Page 20: ...en the setup operation will not modify the previous time and date settings 4 3 4 Backlight on time On the System Setup interface touch the Backlight On Time icon to enter the backlight on time setup interface of the current paging station The user can touch the backlight on time value or the small circle before the Always on option the small circle will be ticked and marked by highlighted indicati...

Page 21: ... 3 7 Parameter Settings Enter the system settings interface touch the parameter settings button to enter the parameter settings interface the interface is as shown below MIC Priority setting Check in the box indicates that MIC input is prior to line input Screen Calibration After the equipment is used for a certain period due to the rise of temperature or other factors the touch point is not preci...

Page 22: ...nt the pen to the center of the otherwise the user may not be able to operate the system If the screen is not properly calibrated resulting in failure of use then press and hold the PAGING ALL button on the front panel of the paging station to reset and recalibrate the screen Set the System log in password The interface will be like the following when setting the system s log in password Input the...

Page 23: ...ponse within the time set below it will automatically transfer to next paging station Overtime rejection if call transfer is not enabled it will reject calls when time is up Overtime setup click OK after changing time limit by keyboard on the interface Set multi user access This paging station could be used by multiple users Different users can specify which partitions they can see and display and...

Page 24: ...agement of multiple user login password and modify permissions can also be wet up There is no user management button on the interface of ordinary users If administrator wants to add this button they can follow the steps below Step 1 click Add to add new users and set up login password and modify permission Step2 as shown in picture below different user could use their own password to log in ...

Page 25: ...ing to their actual needs Administrators can assign the user modify permissions if permissions are not assigned the user can only set the parameters such as backlight time microphone settings log etc and cannot set parameters such as group settings partition management and Network settings ...

Page 26: ...that the equipment is completely disconnected from the power source When any fault occurs please do NOT remove the case for repair without authorization in order to avoid accident or further damages Please do NOT place any corrosive chemicals on or near the equipment 2 After sales services Our Company provides a three year warranty including free replacement of damaged parts against any fault occu...

Page 27: ... No List Quantity 1 Microphone head 1 2 Microphone rod 1 3 SY535 cable 3 m 8 core network cable 1 4 SY542 cable 1 5 m Audio cable 1 5 User Manual 1 6 Quality certificate 1 7 Warranty card 1 8 4P green interface 3 81mm interface 2 9 Power adapter 1 ...

Page 28: ...ic range 20dB AUX input sensitivity 1V output 300 50mV AUX distortion 1Kz 1V AUX 0 3 AUX Signal to Noise Ratio 30K lowpass 68dB Effective frequency of AUX gain limit 3dB 50 18000Hz AUX dynamic range 20dB Effective frequency of monitoring talkback voice 80 16000 Hz Monitoring SNR talkback voice 65dB Working voltage DC 14V Standby power consumption 7 3W Power Supply AC220V 10 50Hz Overall power cons...

Page 29: ...of similar nature Please do NOT remove the cover of the equipment otherwise you may get an electric shock Where necessary repair to the equipment should be conducted by qualified professionals All terminals on the device marked with are live and dangerous and should be connected by trained personnel This is connected to power source via the plug and any failure or danger occurs the user can discon...