manualshive.com logo in svg
background image

1.

FEATURES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2

2.

COMPATIBILITY

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2

3.

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2

3.1.

TOOLS REQUIRED

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2

3.2.

LOCATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

2

3.3.

REMOVING THE OLD THERMOSTAT

. . . . . . . . . . . . . . . . . . . . . . . . 

3

3.4.

MOUNTING THE TX9000TS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

3

3.5.

CONNECTING THE WIRES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

3

3.6.

WIRING DIAGRAMS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9-11

3.7.

COMPLETING YOUR INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . 

3

4.

OPERATING INSTRUCTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.1.

SYSTEM MODE SWITCH

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.2.

FAN MODE SWITCH

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.3.

UP/DOWN ARROW CHANGE KEYS

. . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.3.1. TEMPERATURE ADJUSTMENT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.3.2. CHANGING OTHER SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.4.

NAVIGATION KEYS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.5.

DISPLAY ILLUMINATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.6.

AUDIBLE BEEP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.7.

ICONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.7.1. FLAME ICON  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.7.2. SNOWFLAKE ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.7.3. LOW BATTERY ICON  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.8.

HARDWARE RESET

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

4.9.

SOFTWARE RESET

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5

4.10.

SETTING THE TIME AND DAY

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5

4.11.

TEMPORARY TEMPERATURE OVERRIDE

. . . . . . . . . . . . . . . . . . . . 

5

4.12.

TEMPERATURE HOLD

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5

5.

PROGRAMMING

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5

5.1.

DEFAULT ENERGY STAR

®

TEMPERATURE PROGRAMS

. . . . . . 

5

5.2.

PROGRAMMING THE UNIT

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5

5.2.1.

COPY

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

6

6.

ADVANCED FEATURES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

6

6.1.

FILTER USAGE MONITOR

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

6

6.2.

SWING SETTING

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

6

6.3.

TEMPERATURE CALIBRATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

7

6.4.

ENERGY USAGE MONITOR

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

7

6.5.

PROGRAM LOCK

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

7

6.5.1. TO SET CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

7

6.5.2 TO LOCK SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

7

6.5.3. TO UNLOCK SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

7

7.

SETUP OPTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

7

7.1.

THE DISPLAY FORMAT 12/24 SWITCH #1

. . . . . . . . . . . . . . . . . . . 

7

7.2.

SMART RECOVERY SWITCH #2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

7

7.3.

TEMPERATURE DISPLAY FORMAT F°/C° SWITCH #3

. . . . . . . . 

8

7.4.

5 MIN/2 MIN MINIMUM RUN TIME SWITCH #4

. . . . . . . . . . . . . 

8

7.5.

REPOSITIONING SWITCHES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

8

7.6.

GAS/ELECTRIC JUMPER

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

8

8.

BATTERIES AND MAINTENANCE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

8

9.

TECHNICAL ASSISTANCE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

8

10.

WARRANTY

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

8

SMART TEMP

®

ELECTRONIC THERMOSTAT

INSTALLATION AND OPERATING INSTRUCTIONS

Mt. Laurel, New Jersey 08054, USA 

www.luxproducts.com

TX9000TS SERIES

52019

Choose Heat or Cool

Set Day & Time

Installs Easily

Easy as

1–2–3

•  Please read all instructions carefully before beginning

installation. Save them for future reference. 

•  Before removing any wiring from your existing thermostat,

its wires must be labeled with their terminal designations.

•  Ignore the color of the wires since they may not comply

with any standard.

IMPORTANT!

Thank you for your confidence in our product. To obtain the best
results from your investment, please read these instructions
thoroughly and acquaint yourself with your purchase before
installing your new thermostat. Then follow the installation
procedures, one step at a time.  This will save you time and
minimize the chance of damaging the thermostat and the systems
it controls.
These instructions may contain information beyond that required
for your particular installation. Please save for future reference.

WARNING:

Use Energizer

®

or DURACELL

®

Alkaline Batteries Only.

Energizer

®

is a registered trademark of Eveready Battery Company, Inc.

DURACELL

®

is a registered trademark of The Gillette Company, Inc.

© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED

Содержание Smart Temp TXT9000TS Series

Страница 1: ...SITIONING SWITCHES 8 7 6 GAS ELECTRIC JUMPER 8 8 BATTERIESANDMAINTENANCE 8 9 TECHNICALASSISTANCE 8 10 WARRANTY 8 SMART TEMP ELECTRONIC THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS Mt Laurel New Jersey 08054 USA www luxproducts com TX9000TS SERIES 52019 Choose Heat or Cool Set Day Time Installs Easily Easy as 1 2 3 Please read all instructions carefully before beginning installation Save them...

Страница 2: ...sed with 3 wire zone valves 120V systems or multistage systems Ask your dealer for other LUX thermostats to control those systems 3 INSTALLATION Please read all instructions carefully before beginning installation WARNING Your thermostat is a precision instrument Please handle it with care All wiring must conform to local codes and ordinances Turn off electricity to the appliance before installing...

Страница 3: ...ffecting the thermostat CAUTION Be careful not to drop the body or disturb electronic parts Leave the cover closed while the body is being removed from the base 7 Press up on the thumb latch at the bottom of thermostat and separate the body from its base 8 Hold the base against the wall Route the wires through the hole below the terminal block Position the base for best appearance to hide any mark...

Страница 4: ...sed to adjust temperatures and change other settings 4 3 1 TEMPERATURE ADJUSTMENT Touch the displayed temperature once then touch the UP DOWN arrow key it adjusts the flashing set temperature by one degree in the associated direction Holding the key will automatically advance the setting in the associated direction For simple operation see HOLD 4 3 2 CHANGING OTHER SETTINGS If there are many choic...

Страница 5: ...lashing OVERRIDE will be indicated at the top of the display OVERRIDE will be automatically canceled at the start of the next program period OVERRIDE will be cancelled if the set temperature is adjusted to its programmed value or if the units mode is changed 4 12 TEMPERATURE HOLD HOLD may be used for manual temperature control It is the simplest means to set and maintain a fixed temperature in Hea...

Страница 6: ...Touch EXIT to return to main screen TIP Pressing Day Time or Temperature while programming will shift focus to that setting allowing it to be edited in the order most convenient for you 5 2 1 COPY COPY will copy the previous days programs into the current day and advance the thermostat to the beginning of next day 6 ADVANCED FEATURES 6 1 FILTER USAGE MONITOR The FILTER MONITOR is used to help dete...

Страница 7: ...OWN arrows to count to code number Touch YES ENTER NEW CODE will appear Hold UP DOWN arrows to count to code number Record Code Number Touch YES to accept new code ENTER OLD CODE will be visible Touch EXIT to return to main display 6 5 2 TO LOCK SETTINGS Touch OPEN LOCK SYMBOL on display LOCK KEY will appear Touch YES The display will now show a CLOSED PADLOCK 6 5 3 TO UNLOCK SETTINGS Touch the CL...

Страница 8: ...remove it from the wall 2 Remove the used batteries See battery location and polarity in figure on Page 12 3 Install two new Energizer or DURACELL AA size alkaline batteries in the battery compartment Observe the polarity marking shown in the compartment 4 Hang the top of the unit by the tabs at the top corners of the base then snap the bottom of the unit into place Do not use unnecessary force If...

Страница 9: ...B G Y W W H 4 Y C 6 G F RH RC R V 5 B O C RH RC O B G Y W RH R V G F Y C 6 JUMPER PROVIDED JUMPER PROVIDED WIRING DIAGRAM NOTES APPLIES TO ALL DRAWINGS The DASHED lines are optional depending upon your system type Verify whether C X or B wires are connected to system common If B and O are both present it is likely that B is a system common If a B wire in your system is a common then connecting it ...

Страница 10: ...R 120VAC AC COMPRESSOR FAN SYSTEMCOMMON OPTIONAL RC RH JUMPERPROVIDED WIRING DIAGRAM NOTES APPLIES TO ALL DRAWINGS The DASHED wires are optional depending on your system type Verify whether C X or B wires are connected to system common If B and O are both present it is likely that B is a system common If a B wire in your system is a common then connecting it to the B terminal may cause damage to y...

Страница 11: ...C 5 WIRE SYSTEM HEATING AND COOLING 2 TRANSFORMERS 24VOLT HEAT TRANSFORMER 120VAC 24VOLT COOL TRANSFORMER 120VAC FAN COOLING HEAT OPTIONAL SYSTEMCOMMON RC RH JUMPERREMOVED W Y G B O RC RH C SINGLE STAGE HEAT PUMP SYSTEM 24VOLT SYSTEM TRANSFORMER 120VAC CHANGEOVER HEAT CHANGEOVER COOL B OR O BUTNEVERBOTH FAN HEAT PUMP ADD JUMPER SYSTEMCOMMON OPTIONAL RC RH JUMPERPROVIDED ...

Страница 12: ...RN DAY EVE NIGHT MORN DAY EVE NIGHT MORN DAY EVE NIGHT MORN DAY EVE NIGHT FRI SAT SUN PERIOD HEAT TIME TEMP TIME TEMP COOL 5 2 PROGRAMMING THE UNIT To ease reprogramming later record your thermostat s programs and settings in the table provided below GAS ELEC 1 2 3 4 ON 12hr 24hr 1 U4 SR OFF SR ON 2 F C 3 5min 2min 4 GAS ELECTRIC JUMPER OPTION SWITCHES C RH RC O B G Y W HARDWARE RESET OPTION SWITC...

Отзывы: