Description

The WCK-3B-CC and WCK-6B-CC window covering
keypads are low-voltage contact closure devices that
interface with various shade controllers through their A/V
terminals. These keypads offer Raise, Lower, and Stop
functions of shades that are controlled by the
corresponding shade controller. The three button version
(WCK-3B-CC) is capable of interfacing to a single shade
controller. The six button version (WCK-6B-CC) can
interface to two separate shade controllers. These
keypads are low-voltage devices that are designed to fit
into a standard wallbox. The keypads are gangable with
Lutron

®

 Claro

®  

or Nova T

®

 devices. Proper separation of

low-voltage and line voltage devices is required. Keypads
must be connected to shade controller using Class 2/
PELV wiring methods per the National Electrical Code.
Check with your local inspector for the code requirements
and wiring practices in your area. Lutron offers precision
product color matching.

Important Notes

1. Install in accordance with all applicable regulations.
2.

Do not connect high voltage power to device.

Improper wiring can result in personal injury or damage
to the device or to other equipment.

Cleaning Instructions

To clean keypad wipe with a clean damp cloth. 

DO NOT

use any chemical cleaning solutions.

Installation

1. Turn OFF power feeding shade controller.
2. Run the control wire (4 conductor, 22-24 AWG) from

the shade controller to the wallbox for the keypad.
See Figure A or B.

3.  Strip the insulation 1/2" from the wires.
4.  Using the supplied wire connectors:

For a WCK-3B-CC or the lower section of a
WCK-6B-CC only:
• Connect the YELLOW wire to the wire going

to the Common terminal on the shade controller.

• Connect the GRAY wire to the wire going to the

Down terminal on the shade controller.

• Connect the BROWN wire to the wire going to the

Stop terminal on the shade controller.

     • Connect the VIOLET wire to the wire going to the Up

terminal on the shade controller.

     For a WCK-6B-CC upper section only:
     • Connect the YELLOW/WHITE wire to the wire going

to the Common terminal on the shade controller.

• Connect the GRAY/WHITE wire to the wire going to

the Down terminal on the shade controller.

• Connect the BROWN/WHITE wire to the wire going

to the Stop terminal on the shade controller.

     • Connect the VIOLET/WHITE wire to the wire going to

the Up terminal on the shade controller.

5. Using two screws, securely mount the keypad to the

wallbox. See Figure C.

6. Install wallplate (purchased separately).
7.  Restore power feeding the shade controller(s).

Figure A - WCK-3B-CC Keypad wiring

Figure B - WCK-6B-CC Keypad wiring

Caution - 

Do not over

tighten screws.

Figure C - Keypad mounting

DOWN

22-24 AWG wire

STOP

COMMON

BROWN

GRAY

YELLOW

G
N
D

D
W
N

U
P

         SHADE
   CONTROLLER

UP

VIOLET

S
T
P

Twist wire

connector tight.

Be sure no bare

wire is exposed.

DOWN

COMMON

STOP

YELLOW/WHITE

GRAY/WHITE

BROWN/WHITE

UP

VIOLET/WHITE

COMMON

STOP

YELLOW

GRAY

BROWN

UP

VIOLET

DOWN

G
N
D

U
P

D
W
N

      SHADE
CONTROLLER

S
T
P

G
N
D

U
P

D
W
N

      SHADE
CONTROLLER

S
T
P

22-24 AWG wire

Twist wire

connector tight.

Be sure no bare

wire is exposed.

Window Covering Keypad

Operating Instructions
Please Leave for Occupant