User manual

LSK FuelGaugePro2

Digital Universal Floatless Fuel gauge

Thank you for showing interest in our products. I strongly advise you to read this user

manual   thoroughly.   It   contains   important   instructions   about   installation,   setup   and   use   of   the

gauge.   By   obeying   these   instructions,   the   product   will   reward   you   with   long   time   flawless

functionality. 

Rev. 1.3, Date: 28.5.2018 

1

Summary of Contents for FuelGaugePro2

Page 1: ...ing interest in our products I strongly advise you to read this user manual thoroughly It contains important instructions about installation setup and use of the gauge By obeying these instructions the product will reward you with long time flawless functionality Rev 1 3 Date 28 5 2018 1 ...

Page 2: ...the setting menu 13 The settings diagram 14 Examples of various settings 15 Basic use Min max mode 15 Autocalibration mode 15 Enable dot mode and disable blinking of first led 16 Restore default 16 Possible faults 16 Warranty period 17 Safety warnings 17 Recycling 18 Manufacturer 18 Device desctription This device is useful for a motorcycles and ultralight aircrafts excavators tractors etc without...

Page 3: ...plained in this document below If the fuel gauge is connected under a vacuum controlled fuel cock that needs to work just fine and not remain partially closed It only works on bikes with a 12 volt electrical system It does not work on 6 volts This can be solved by a 6V 12V converter that can be purchased in our website In case of need we will help with any uncertainties It can be used on other mac...

Page 4: ...imensions X 35 mm Y 40 mm Y 20 mm without hose plug X 1 37 in Y 1 57 in Y 0 78 in without hose plug Display dimensions X 52 mm Y 35 mm Z 16 mm X 2 04 in Y 1 37 in Z 0 62 in Answers on FAQ The gauge is not affected with fall of the bike on the ground The fuel gauge has linear measuring Every bar means a twelfth of the amount of fuel or a twelfth of the pressure generated by the fuel The showed decl...

Page 5: ...annot guarantee the correct function on all motorcycles with a fuel pump The external fuel pump may cause problems with measuring on some motorcycles If this problem occurs you can return FuelGauge to us and we will return your money back to you Device must be in intact condition 5 ...

Page 6: ...st accurate Do not place the unit on hot places It can handle temperature up to 60 C 140 F Check if the display can reach your desired spot if the cable is long enough If you can connect the gauge to the hose between the fuel tank and the fuel cock not necessary see picture below The sensor unit can be in any position lying or even with the fuel hose going up The best fuel gauge sensor placement 6...

Page 7: ...Placement with the external fuel pump 7 ...

Page 8: ...The fuel gauge sensor alternative placement 8 ...

Page 9: ...crew it on some place of the frame or even to the pole of the battery It can be also attached to any other wire usually black using the cut in connector included in the package but you must be 100 sure it is a wire Red cable Use the cut in connector to connect it to another cable that is switched on with the ignition You can observe that by trying the gauge with its cable on cable of the motorcycl...

Page 10: ... fuel levels minimal level and full fuel level The LED segments lights in linear dependence on fuel level height of fuel in the tank Auto calibration mode In this mode the device is displaying real amount of the fuel even if the fuel tank shape is very varied This mode is more difficult to set than min max mode Device settings 1 Calibration settings Empty tank level Save this value when fuel tank ...

Page 11: ...et measure mode If calibration menu was opened mode has to be set considering with used mode Note for bikes with VACUUM FUEL COCK During the calibration the engine should be running the vacuum fuel cocks must be opened the motorcycle should stand straight not on emergency stand and both the control unit and the fuel tank must be in their final position 2 Display settings Bar dot mode The display i...

Page 12: ...All saved settings and calibration data will be lost Setup button Setup button is located in the right corner of display It is magnetic sensor responsive to the proximity of the magnet magnet is enclosed in the package The test of the magnetic sensor can be performed by placing a magnet near the sensor If device is not in the settings mode normal mode all LED segments will be lighted when magnet i...

Page 13: ...the menu exists two events first event is called click and second one is called confirm C l i c k Click event is primary usable for skipping items in the menu Click is performed by to proximity the magnet to the magnetic sensor for a short time and get it out C o n f i r m Confirm event is usable for confirming items in the menu change the default value to perform calibration etc Confirm event is ...

Page 14: ...ar dot showing mode CONFIRM Dot mode CLICK Bar mode CLICK Full tank level CONFIRM Save full tank level CLICK Flashing first LED CONFIRM Not flashing CLICK Flashing Measure mode CONFIRM Min max mode CLICK AutoCal mode Reverse display CONFIRM Reverse CLICK Normal Autocalibration process CONFIRM Start AutoCalibration AutoCal measure mode enabled automatically CLICK EXIT CLICK in process MANUALLY STOP ...

Page 15: ...tank The fuel tank must be empty Confirm Save value of the full fuel tank The fuel tank must be full Confirm Set mode Min max mode Click Skip auto calibration item Settings menu is closed Autocalibration mode It is required prepared and connected device to the fuel system and fuel tank must be full before auto calibration Holt magnet near sensor for time more than 2 sec enter to the settings menu ...

Page 16: ... first LED blinking Click Enable direct LED order Settings menu is closed Device is in the measure mode Restore default Holt magnet near sensor for time more than 2 sec Enter to the settings menu Click Skip the calibration menu Click Skip the display settings menu Confirm Restore default settings Possible faults If you obey all the instructions this fuel gauge should work properly without any need...

Page 17: ...s wrong but connections is ok display shows one lighted LED which goes forward and backward If nothing helps write at info lskelectronics com and request money return Warranty period Warranty is guaranteed for two years after the day of purchase We provide warranty and post warranty service If you don t obey instructions in this user manual warranty can be rejected Safety warnings The gauge should...

Page 18: ...nded to authorities on places designed for collecting old electrical devices Packaging should be thrown out into an appropriate bin Manufacturer LSK Motorcycle electronics Website www lskelectronics com Manufactured in compliance with RoHS norm 18 ...