2  Remote Controls

This opener is supplied with a three-button remote control (the second and third buttons can be used to control an 
additional opener or gate if it contains a Linear MegaCode™ receiver). Additional single and multi-button remote 
controls can be purchased. The short wire on the back of the opener serves as an antenna for the remote controls. 
Do  not  cut  off  the  wire  or  the  remote  controls  will  not 
operate well.

To Add or Remove a Remote Control 

1  Press the opener’s LEARN button. The opener’s light 

and  red  light  will  flash  once  and  turn  on  for  about 

15 seconds. 

A remote must be added or removed 

while the red light is still on.

2  Send a signal from a remote. The opener’s light and 

the red light will flash once if a remote was added, or 

the opener’s light and the red light will flash four times 

if a remote was removed.

3  Repeat Steps 1 & 2 for any additional remote controls.

To Remove all Remote Controls

1  Press  and  hold  the  opener’s  LEARN  button  for  ten 

seconds or more.

2  Release  the  LEARN  button.  The  red  light  and 

opener’s light will blink three times signaling that 

all  of  the  remotes  in  the  opener’s  memory  were 

erased. The red light will turn off, then turn on for 15 

seconds. A remote control can be entered during this 

time using Step 2 above.

Testing

1  Before testing the remote control, straighten out the 

opener’s antenna wire so it points up.

2  Stand clear of the door, press the remote control’s 

button and verify that the opener starts.

Replacing a Remote Control’s Batteries

When  the  red  light  on  the  remote  glows  dimly,  or  fails 

to light at all when the remote is activated, the batteries 

need replacing.
1  Open the remote’s case and remove the circuit board.
2  Replace old batteries with two Type 2032 batteries.
3  Re-assemble the remote.

3  Garage Door Opener Maintenance

Weather conditions may affect the door operation which 
could require some re-setting of the opener’s adjustments. 
Doors may swell and become heavier during wet periods, 
door hinges and rollers might bind during cold periods. To 
insure safe operation of the door, perform the following 
tests, including any additional test steps described.

Every Month

1  With the door closed, pull the red release handle to 

disconnect the opener from the door.

2  From  outside  the  garage,  slowly  open  the  door 

manually  all  the  way,  and  then  close  it  all  the  way. 

Notice if there is any binding, sticking or rubbing. The 

door should move smoothly in both directions.

3  Raise  the  garage  door  about  halfway  up.  Carefully 

release  the  door  and  see  if  the  door  balances.  It 

should stay in place. Close the door.

� 

NOTE:

  If  the  garage  door  is  unbalanced  or  the 

door travel isn’t smooth, have a qualified garage door 
professional adjust or repair the door.

4  To reconnect the opener, flip the release lever up and 

run the opener.

5  Perform the Safety Beam Test (Section 4).
6  Perform the Safety Reversal System Test as described 

in Section 8.

After Servicing the Opener

1  Perform the Safety Beam Test (Section 4).
2  Perform  the  Open  and  Close  Limit  Adjustments 

(Section 5).

3  Perform the Safety Reversal System Test (Section 8).

Every 6 Months

Check the belt or chain tension.
•  For belt-drive rails, examine the length of the tension 

spring in the traveler. It should be about 1” long.

•  For  chain-drive  rails,  examine  the  spacing  between 

the turnbuckle and the rail. The turnbuckle should be 

slightly above the rail.

� 

NOTE:

 Too much or too little chain tension will cause 

excessive sprocket noise.

Chain Adjustment

If necessary, use the following steps to adjust the chain.
1  Hold the turnbuckle with a flat blade screwdriver and 

loosen the two locknuts with a 7/16” end wrench.

2  Twist the turnbuckle to adjust the chain tension. Adjust 

the chain until the turnbuckle is sightly above the rail.

3  Hold the turnbuckle with a flat blade screwdriver and 

tighten the two locknuts with a 7/16” end wrench.

Belt Adjustment

The tension spring in the traveler keeps the belt taut. The 

factory setting for the tension spring length is .9” long. If 

the tension spring is longer than 1”, adjust the belt.
1  Hold  the  traveler  so  the  adjustment  wheel  is  visible 

through the large slot.

2  Use  a  flat  blade  screwdriver  to  turn  the  adjustment 

wheel to compress the tension spring until its length 

is between .9” and 1” long.

Every Year

Check the door hardware for lubrication needs. Lubricate 

door  hinges,  rollers  and  bearings  according  to  door 

manufacturer’s recommended procedures.

MODEL LDCO800 

BELT-DRIVE OR CHAIN-DRIVE 

DC MOTOR GARAGE DOOR OPENER

HOMEOWNER’S INSTRUCTIONS 

For Sectional Type Doors

IMPORTANT SAFETY NOTES

Please read the instructions carefully! This garage door opener is designed to provide safe and reliable service if installed 
and tested as described in these instructions. A garage door is the largest mechanical appliance in a residence. Care 
must be taken to prevent injury or death during installation and operation of the garage door and garage door opener.

THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES IN THESE INSTRUCTIONS.

1  Using the Garage Door Opener

Opening the Door

1  With  the  door  in  view,  press  the  wall  station’s  UP/

DOWN  ARROW  button,  the  button  assigned  to  the 

opener on the remote control, or enter a valid access 

code and press START/STOP on a remote keypad.

2  When the opener is activated, the opener’s light will 

turn on and the door will begin to open.

3  The door will open until the open limit is reached. If 

an obstacle is encountered (opener’s light flashes four 

times) while the door is opening, the door will stop.

4  The opener’s light will stay on for about five minutes 

after the door stops.

Closing the Door

1  With  the  door  in  view,  press  the  wall  station’s  UP/

DOWN ARROW button or the button assigned to the 

opener on the remote control, or enter a valid access 

code and press START/STOP on a remote keypad.

2  When the opener is activated, the opener’s light will 

turn on and the door will begin to close.

3  The door will close until the close limit is reached. If 

an obstacle is encountered (opener’s light flashes four 

times), or the safety beam is interrupted (opener’s light 

flashes three times) during closing, the door will stop, 

then re-open.

4  The opener’s light will stay on for about five minutes 

after the door stops.

Stopping the Door Mid-travel

1  The door can be stopped immediately at any time 

by pressing the wall station’s UP/DOWN ARROW 

button, the remote control’s pushbutton, or press 

the START/STOP button on a remote keypad (if the 

remote keypad was used to start the door).

2  The  next  time  the  opener  is  activated,  the  door  will 

move in the opposite direction.

Vacation Lock for Additional Security

1  Slide  the  wall  station’s  LOCK  switch  to  the  locked 

position to prevent remote controls from opening the 

door after the door is completely closed. The remotes 

can close the door, but not open it. The door can still 

be opened or closed by using the wall station’s UP/

DOWN ARROW pushbutton.

� 

NOTE:

 To signal that the vacation switch is locked, 

the opener’s light and red light will flash five times if a 
remote is activated in an attempt to open the door.

2  Slide the wall station’s LOCK switch to the unlocked 

position to return the opener to normal operation.

Controlling the Opener’s Light

1  The  opener’s  light  can  be  lit  by  pushing  the  wall 

station’s LIGHT button. The light will remain on until 

the  LIGHT  button  is  pressed  again  or  the  opener  is 

cycled.

2  If  the  opener’s  light  is  on,  pushing  the  wall  station’s 

LIGHT button will turn the opener’s light off.

Disconnecting the Door from the Opener

1  With  the  door  in  any  position  (preferably  closed), 

carefully pull the red release handle. 

USE CAUTION 

IF THE DOOR IS OPEN, THE DOOR MAY DROP.

2  The  disconnected  door  can  be  opened  or  closed 

manually.

3  To  reconnect  the  opener,  flip  the  release  lever  up. 

Raise  or  lower  the  door  manually  until  the  opener 

reconnects.

IMPORTANT USER SAFETY INSTRUCTIONS

  WARNING 

A MOVING GARAGE DOOR CAN CAUSE INJURY OR DEATH! 

TO REDUCE THE RISK OF DEATH OR SEVERE INJURY:

1  READ AND FOLLOW ALL INSTRUCTIONS.
2  Use this operator only with sectional overhead doors no more than 10 ft. tall.
3  NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL 

AWAY FROM CHILDREN!

4  Always keep moving door in sight and away from people and objects until it is completely closed. NO 

ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

5  NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.
6  Test door opener monthly. The garage door MUST reverse on contact with a 1-1/2 inch object (or a 2x4 

board laid flat at the center of the door) on the floor. If adjusting either the force or the limit of travel, 
re-test the door opener. Failure to adjust the opener properly may cause severe injury or death.

7  If possible, use the red emergency release handle only when the door is closed. Use caution when 

using this release with the door open. Weak or broken springs may cause the door to fall rapidly, 
causing injury or death.

8  KEEP  GARAGE  DOORS  PROPERLY  BALANCED.  (See  Garage  Door  Opener  Maintenance)  An 

improperly balanced door could cause severe injury or death. Have a qualified service person make 
repairs to cables, spring assembly and other hardware.

9

 

SAVE THESE INSTRUCTIONS.

THE DOOR SHOULD

BALANCE WITHOUT

GOING UP OR DOWN

CHECKING THE DOOR BALANCE

TEST WITH SMALL OBSTACLE

THE DOOR MUST REVERSE
WITHIN 2-SECONDS AFTER
IMPACT WITH A 2 x 4 BOARD

2 x 4 BOARD LAID FLAT
UNDER CENTER OF DOOR

TESTING THE SAFETY REVERSAL SYSTEM

IF PROPERLY

BALANCED, THE 

DOOR WILL STAY AT A 

HALFWAY POSITION

IF PROPERLY

BALANCED, THE 

DOOR WILL STAY AT A 

HALFWAY POSITION

PRINTER’S INSTRUCTIONS:

INSTR,HOMEOWNERS,LDCO; LINEAR P/N: 228356 C; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 11.000” x 17.000”; FOLDING: 1-FOLD VERTICAL, 1-FOLD HORIZONTAL, FINISH 8.500” X 5.500” WITH LOGO SHOWING; SCALE: 1-1; SIDE 1 OF 2 

  WARNING 

This  type  of  warning  note  is  used  to  indicate 

possible  mechanical  hazards  that  may  cause 

serious injuries or death.

  CAUTION 

This type of warning note is used to indicate 

the possibility of damage to the garage door or 

garage door opener.

  WARNING 

The garage door opener must not be installed 

and used on an unbalanced door. The opener’s 

internal  door  force  sensor  will  not  function 

properly  on  an  unbalanced  door.  Risk  of 

serious injury or death may result.

  WARNING 

Garage  door  hardware  (springs,  cables, 

brackets,  pulleys,  etc.)  are  under  extreme 

pressure  and  tension.  DO  NOT  ATTEMPT  TO 

LOOSEN,  TIGHTEN  OR  ADJUST  ANY  DOOR 

HARDWARE.  CALL  A  QUALIFIED  GARAGE  DOOR 

INSTALLATION PROFESSIONAL!

  WARNING 

Always  perform  the  entire  Safety  Reversal 

System Test (see Section 8) after making any 

adjustments to the opener.

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

TO DISCONNECT OPENER

PULL THE RED
RELEASE HANDLE

TO DISCONNECT
THE OPENER FROM
THE DOOR

FLIP THE LEVER UP

AND RAISE OR

LOWER THE DOOR
TO RECONNECT

THE OPENER

TO RECONNECT OPENER

  WARNING 

Children  operating  or  playing  with  a  garage 

door  opener  can  injure  themselves  or  others. 

The  garage  door  could  cause  serious  injury 

or death. Do not allow children to operate the 

remote control(s) or the wall station. A moving 

garage door could injure or kill someone under 

it.  Activate  the  opener  only  when  the  door 

is  clearly  visible,  free  of  obstructions  and 

adjusted properly.

SEND A SIGNAL
FROM A REMOTE

THE OPENER'S LIGHT AND RED

LIGHT WILL FLASH ONCE IF A

REMOTE IS ADDED, THE OPENER'S

LIGHT AND THE RED LIGHT

WILL FLASH FOUR TIMES

IF A REMOTE IS REMOVED

1

2

ADDING OR REMOVING A REMOTE

PRESS A
BUTTON - OR -

ENTER A CODE
AND PRESS START/STOP

PRESS THE LEARN BUTTON
FOR 10 SECONDS OR MORE

1

2

REMOVING ALL REMOTES

THE RED LIGH

AND OPERATOR’S LIGHT

T

WILL BLINK 3 TIMES

SIGNALING THAT

ALL REMOTES
WERE REMOVED

PRESS THE
LEARN BUTTON

REMOTE MUST BE ENTERED
WHILE RED LIGHT IS ON

2

PREPARING TO ADD OR REMOVE A REMOTE

1

THE RED LIGHT WILL

GLOW FOR 15 SECONDS

TURNBUCKLE
LOCKNUTS

TO OPENER LOCKNUTS

TIGHTEN

LOCKNUTS

LOOSEN

HOLD TURNBUCKLE
WITH FLAT BLADE
SCREWDRIVER TO
BACKUP LOCKNUTS

TWIST

TURNBUCKLE

CHAIN

TIGHTEN CHAIN

LOOSEN

ADJUSTING A CHAIN-DRIVE

PRESS THE

WALL STATION'S

UP/DOWN ARROW

PRESS A REMOTE

CONTROL BUTTON

OPENING OR CLOSING THE DOOR

- OR -

- OR -

ENTER AN

ACCESS CODE

AND PRESS

START/STOP

WALL STATION

REMOTE CONTROL

REMOTE

KEYPAD

WALL

STATION

REMOTE

KEYPAD

REMOTE
CONTROL

THE DOOR CAN BE STOPPED
AT ANY POSITION USING THE

WALL STATION, REMOTE CONTROL,

OR A REMOTE KEYPAD

STOPPING THE DOOR

LOCK

UNLOCK

PREVENTING REMOTES

FROM OPENING THE DOOR

SLIDE THE VACATION SWITCH

DOWN TO LOCK (REMOTES DISABLED)

OR UP TO UNLOCK (REMOTES NORMAL)

CONTROLLING THE
OPENER'S LIGHT

PRESS THE LIGHT
BUTTON TO TURN THE
LIGHT ON OR OFF

THE LIGHT WILL STAY ON UNTIL
THE LIGHT BUTTON IS PRESSED
OR THE OPENER IS CYCLED

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

IN CASE OF POWER FAILURE
OR IF DOOR BECOMES OBSTRUCTED

PULL THE RED
RELEASE HANDLE

TO DISCONNECT
THE OPENER FROM
THE DOOR

FLIP THE LEVER UP
AND RAISE OR
LOWER THE DOOR
TO RECONNECT
THE OPENER

PROFESSIONAL INSTALLATION BY:

1

TWIST DIME IN 
SLOT TO OPEN 
CASE

2

LIFT OFF
THE TOP OF
THE CASE

3

CAREFULLY
REMOVE THE
CIRCUIT BOARD

5

INSERT TWO NEW
TYPE 2032 BATTERIES
PLUS SIDE UP THEN

REASSEMBLE UNIT

NOTE: THE CIRCUIT BOARD WILL FIT ONLY ONE 

WAY INTO THE CASE. ALIGN THE PLASTIC POST 
IN THE CASE WITH THE HOLE IN THE CIRCUIT BOARD

REPLACING A REMOTE'S BATTERY

4

REMOVE OLD 
BATTERIES AND 
DISPOSE OF THEM PROPERLY

ADJUSTING A BELT-DRIVE

TIGHTEN

LOOSEN

TURN THE ADJUSTMENT
WHEEL UNTIL THE TENSION
SPRING IS ABOUT 1" LONG

ADJUSTMENT WHEEL

MEASURE THE TENSION
SPRING LENGTH

TRAVELER

WHENEVER OPERATING
THE LIGHT WILL TURN ON
FOR ABOUT 5 MINUTES

NOTE: A FLASHING

LIGHT INDICATES

TROUBLE

SAFETY LIGHTING