User and Installation Instructions  

 

Electric Fume Filtration Units 

 

L3 and L4 

 

Summary of Contents for L3

Page 1: ...IS346 ECN3219 User and Installation Instructions Electric Fume Filtration Units L3 and L4 ...

Page 2: ...e produce over 450 different items of catering equipment and our range is constantly being extended and improved Find out more about Lincat products from your local distributor or direct from us CONTENTS CONTENTS Error Bookmark not defined SAFETY INFORMATION 3 DELIVERY CHECKLIST 3 TECHNICAL SPECIFICATION 4 INSTALLATION 4 OPERATION 6 CLEANING 7 MAINTENANCE 8 SPARE PARTS 8 SERVICE INFORMATION 9 GUAR...

Page 3: ...aged If it is it must be replaced by Lincat Ltd or by qualified personnel Always disconnect the unit from the electricity supply before servicing The unit must be earthed Do not try to modify this unit Keep these instructions in a safe place for future reference DELIVERY CHECKLIST Electric fume filtration unit With electrical supply cable and 10A plug User installation instructions Guarantee card ...

Page 4: ...om ventilation with no cross draughts 7 10 air changes per hour Install the filtration unit so that there is an air space above it with the front lower edge of the canopy about 800mm above the cooking surface The front edge should overlap the cooking area by approximately 100mm For safety regulations the plug or means of disconnection must always be accessible Using a no 4 masonry drill drill hole...

Page 5: ...IS346 ECN3219 Fig 1 14 0 317 0 14 0 50 0 304 0 51 0 14 0 317 0 14 0 345 0 405 0 345 0 74 9 Fig 2 15 0 304 0 65 0 317 0 14 0 75 0 715 0 ...

Page 6: ...lows Green and yellow wire Earth E Blue wire Neutral N Brown wire Live L OPERATION Plug the unit into the mains supply Turn the power switch on as indicated in Fig 3 the fans will run until the unit is switched off To use the lights turn on the light switch as indicated in Fig 3 Figure 3 FRONT VIEW This unit is fitted with a safety thermostat which will cut power to the fans in the event of a fire...

Page 7: ...maintain efficient performance and hygiene Disconnect the unit from the electricity supply and allow to cool before starting to clean Use a mild detergent in hot water and a soft cloth Do not allow excess water to run into the unit Do not use abrasive creams or scourers Burnt on food may be removed using Carb n off or similar cleaner ...

Page 8: ...er Filters Ensure that the unit is turned off and unplugged from the mains Release the 2 suitcase latches and open the door Slide filters out of unit and replace with new ones Close and secure door SPARE PARTS Description Part No L3 L4 On Off switch SW66 1 1 Light Switch SW70 1 1 Light Bulb LA08 2 2 Safety Thermostat TH73 1 1 Centrifugal Fan FA25 2 3 Power Cable Plug Lead PL201 1 1 Suitcase Style ...

Page 9: ...problem Product code Type number Serial number From serial plate Lincat reserve the right to carry out any work under warranty during normal working hours ie Monday to Friday 08 30 a m 17 00 p m GUARANTEE This unit carries a comprehensive UK twelve month warranty The guarantee is in addition to and does not diminish your statutory or legal rights The guarantee does not cover Accidental damage misu...