3-Way or More Applications (Multi-location)
Device Remotes
Cat. No. VZØØR-10, Coordinating Dimmer Remote (For use with Vizia and Vizia RF devices)
Cat. No. VZØØR-1L, Matching Dimmer Remote (For use with Vizia devices only)
Cat. No. VZØSR-10, Coordinating Switch Remote (For use with Vizia and Vizia RF devices)
Cat. No. VZØSR-1L, Matching Switch Remote (For use with Vizia devices only)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-
operated appliance.
• For Hi-lume
®
or Eco-10™ (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications.
• Vizia™ remotes are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ devices for multi-location switching.
• Use only Vizia Coordinating Remotes with Vizia RF devices
WARNINGS AND CAUTIONS:
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s)
will turn the light on at the brightness level selected at the dimmer.
• Recommended minimum wall box depth is 2-1/2".
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Tools needed to install your Remote:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
INSTALLING YOUR REMOTE
NOTE:
Use check boxes when Steps are completed.
Step 1
WARNING:
TO AvOID fIRE, ShOCk, OR DEATh;
TURN Off pOWER
at circuit breaker or fuse and test
that power is off before wiring!
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
3
5
1
2
6
4
2
4
1
5
3
4-Way
1.
First Traveler – note color
2.
Second Traveler – tagged
3.
Neutral
4.
Ground
5.
Third Traveler – note color
6.
Fourth Traveler – tagged
NOTE:
For matching remote
w/LEDs installation, the
first
Traveler
becomes Line Hot.
3-Way
1.
Line or Load
(See important
instruction below)
2.
Neutral
3.
Ground
4.
First Traveler – note color
5.
Second Traveler – note color
NOTE:
For matching remote
w/LEDs installation, the
first
Traveler
becomes Line Hot.
Identifying your wiring application (most
common):
NOTE:
If the wiring in the wall box does not resemble
any of these configurations, consult a qualified
electrician.
Step 2
IMpORTANT:
for 3-Way applications
, note that one of the screw terminals from
the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify
as the common (Line or Load) in both the dimmer wall box and
remote wall box.
for 4-Way applications
, note that the old switch being removed
will have 4 screws plus a ground screw. Tag the two same color
insulated wires with electrical tape.
3-Way Wiring with Matching Remote (w/LEDs)
Application:
NOTE:
Incandescent and Magnetic Low-Voltage
installations only.
NOTE:
Matching remotes are for use with non RF devices
only.
NOTE: Screw terminal dimmer depicted.
Step 4a
Bk
YL/RD RD
Bk
YL/RD
Wh
RD
4
3
2
1
5
Terminal
Screw marked
Black (Bk)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Coordinating Remote
Dimmer
2
4
3
5
1
hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDs)
YL/RD
YL/RD
RD
Wh
RD
Bk
Bk
Black
not used
White
Line
120vAC, 60hz
Green
Ground
Green
Ground
3-Way Wiring with Coordinating Remote (no LEDs)
Application:
NOTE:
Incandescent and Magnetic Low-Voltage
installations only.
NOTE: Screw terminal dimmer
depicted.
Step 4b
NOTE:
The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with
a Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE:
Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
Wiring Matching Remote (wall box with Line hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to dimmer terminal screw marked “BK”
or the Black dimmer lead.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked “YL/RD”
(note wire color)
. This traveler from the
remote must go to the terminal screw on the dimmer marked “YL/
RD” or the Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked “WH”.
Wiring Dimmer (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked “RD” or the Red dimmer lead.
• First Traveler Line Hot to dimmer terminal screw marked “BK” or the
Black dimmer lead.
• Remove Red insulating label from terminal screw marked “YL/RD”
or Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked “YL/RD” or the Yellow/Red dimmer lead.
This traveler from the dimmer must go to the terminal screw on the
remote marked “YL/RD”.
• proceed to Step 6.
Step 4d cont’d
Cut
(if necessary)
preparing and connecting wires:
This remote can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
Step 3
Side Wire Connection
Side wire terminals accept
#14 AWG solid copper wire
only.
Strip Gage (measure
bare wire here or
use gage on back of
the dimmer)
Bl
5/8"
(1.6 cm)
Back Wire
(either hole may be used)
Back wire openings use
#14-12 AWG solid copper wire
only.
5/8"
(1.6 cm)
Strip Gage (measure
bare wire here or
use gage on back of
the dimmer)
• Make sure that the ends of the wires from the wall box are
straight
(cut if necessary).
• Remove insulation from each wire in the wall box as shown.
PK-93393-10-00-2C
Changing the color of your Remote:
Your Remote may include three color options. The Remote ships
with the White frame attached. To change color of frame, proceed
as follows:
push in side at tab
to release
Line up tabs and press
in side to attach
Bk
YL/RD RD
Bk
YL/RD
Wh
RD
4
3
2
1
5
Additional
Neutral Wire
Terminal
Screw marked
Black (Bk)
Terminal
Screw marked
White (Wh)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Dimmer
Matching Remote
4
3
5
1
2
hot (Black)
Neutral (White)
Load
Dimmer
Matching Remote (no LEDs)
YL/RD
YL/RD
RD
Wh
Bk
Bk
Black
White
Line
120vAC, 60hz
Green
Ground
Green
Ground
Step 2 cont’d
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
When using the coordinating remote without LEDs, the dimmer
can be installed on either the Line or Load side of the 3-way circuit.
NOTE:
Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to dimmer terminal screw marked "BK" or Black dimmer
lead.
• First Traveler wall box wire to terminal screw marked "RD" or Red
dimmer lead
(note wire color)
. This traveler from the dimmer must
go to the terminal screw on the remote marked "RD".
• Remove Red insulating label from terminal screw marked
"YL/RD" or Yellow/Red dimmer lead.
• Second Traveler wall box wire to terminal screw marked "YL/RD" or
Yellow/Red dimmer lead
(note wire color)
. This traveler from the
dimmer must go to the terminal screw on the remote marked "YL/RD".
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
Maximum wire length from dimmer to last remote is
300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked "BK".
• First Traveler wall box wire
(note color as above)
to terminal screw
marked "RD". This traveler from the remote must go to the terminal
screw on the dimmer marked "RD" or Red dimmer lead.
• Second Traveler wall box wire
(note color as above)
to terminal
screw marked "YL/RD". This traveler from the remote must go to
the terminal screw on the dimmer marked "YL/RD" or Yellow/Red
dimmer lead.
• Remote terminal screw marked "WH" should have White insulation
label affixed.
NOTE:
If insulating label is not affixed to terminal screw marked
"WH", use electrical tape to cover.
•
proceed to Step 6.
3-Way Wiring with Matching Remote (w/
LEDs) for Controls with Neutral Connection
Application:
NOTE:
Electronic Low-Voltage, Mark 10™, Quiet Fan
Speed and Electronic Switch installations only.
NOTE:
Matching remotes are for use with non RF devices
only.
NOTE: Dimmer is depicted.
Step 4c
BK
YL/RD
WH
4
3
5
Additional
Neutral Wire
Control
Matching Remote
4
3
5
1
2
Black
Green
White
Red
Yellow/Red
1
2
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
RD
Hot (Black)
Neutral (White)
Control
c
Mat hing Remote (w/LEDs)
YL/RD
Yellow/Red
Red
WH
BK
Black
Black
White
Load
Line
120VAC, 60Hz
White
Green
Ground
Green
Ground
NOTE:
The control must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with
a Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE:
Maximum wire length from control to all installed remotes
cannot exceed 300 ft (90 m).
WIRING MATChING REMOTE (wall box with Line hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to terminal screw marked "BK" or Black
dimmer lead.
• Second Traveler wall box wire from control to remote terminal screw
marked "YL/RD"
(note wire color)
. This traveler from the remote
must go to terminal screw marked "YL/RD" or Yellow/Red control
lead.
• Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw or
Green control lead.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked "RD" or
Red control lead.
• First Traveler Line Hot to terminal
screw marked "BK" or Black
control lead.
• Remove Red insulating label from
terminal screw marked "YL/RD" or
Yellow/Red control lead.
• Second Traveler wall box wire
(note color as above)
to terminal
screw marked "YL/RD" or Yellow/
Red control lead. This traveler
from the control must go to the
terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to terminal screw marked "WH" or
White control lead.
•
proceed to Step 6.
BK
YL/RD
WH
Control
Coordinating Remote
3
1
3
4
5
Black
White
Green
Red
Yellow/Red
2
1
4
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
2
RD
5
Hot (Black)
Neutral (White)
Control
r
Coo dinating Remote (no LEDs)
YL/RD
Yellow/Red
RD
White
Red
Black
Black
BK
WH
White
Load
Line
120VAC, 60Hz
not used
not used
Green
Ground
Green
Ground
3-Way Wiring with Coordinating Remote (no
LEDs) for Controls with Neutral Connection
Application:
NOTE:
Electronic Low-Voltage, Mark 10™, Quiet
Fan Speed and Electronic Switch installations only.
NOTE: Dimmer is depicted.
Step 4d
WIRING CONTROL:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
The control must be installed in a wall box that has a Line Hot
Connection.
NOTE:
Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw or
Green control lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked "BK" or Black control lead.
• First Traveler wall box wire to terminal screw marked "RD" or Red
control lead
(note wire color)
.
• Remove Red insulating label from terminal screw marked "YL/RD"
or Yellow/Red control lead.
• Second Traveler wall box wire to terminal screw marked "YL/RD"
or Yellow/Red control lead
(note wire color)
. This traveler from
the control must go to the terminal screw on the remote marked
"YL/RD".
• Line Neutral wall box wire to terminal screw marked "WH" or White
control lead.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
"BK" and "RD" terminals on coordinating remote are
unused. Tighten both screws.
NOTE:
Maximum wire length from control to last remote is
300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch
to First Traveler
(note color as above)
.
• Second Traveler wall box wire
(note color as above)
to terminal
screw marked "YL/RD". This traveler from the remote must go to
the terminal screw marked "YL/RD" or Yellow/Red control lead.
• Remove White insulating label from terminal screw marked
"WH".
• Line Neutral wall box wire to terminal screw marked "WH".
•
proceed to Step 6.
4-Way Wiring with Matching Remote (w/LEDs)
Application
:
NOTE:
Incandescent and Magnetic Low-Voltage
installations only.
NOTE:
Matching remotes are for use with non RF
devices only.
NOTE: Screw terminal dimmer depicted.
Step 5a
Bk
YL/RD RD
Bk
YL/RD
Wh
RD
Bk
YL/RD
Wh
RD
4
3
2
1
5
Additional
Neutral Wire
Matching Remote
(3-Way Wall box from Step 2)
Matching Remote
(4-Way Wall box from Step 2)
Dimmer
(3-Way Wall box from Step 2)
4
4
3
3
5
5
1
2
Additional
Neutral Wire
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Black (Bk)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Black (Bk)
Terminal
Screw marked
White (Wh)
Terminal
Screw marked
White (Wh)
6
2
1
hot (Black)
Neutral (White)
Load
Dimmer
Matching Remote
(w/LEDs)
Matching Remote
(w/LEDs)
YL/RD
YL/RD
YL/RD
RD
Wh
Wh
Bk
Bk
Bk
Black
White
Line
120vAC, 60hz
Green
Ground
Green
Ground
Green
Ground
NOTE:
The dimmer
must
be installed in a wall box that has a Load
connection. The matching remote
must
be installed in a wall box
with a Line Hot connection and a Neutral connection. A Neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE:
Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
WIRING MATChING REMOTE (4-Way wall box with Line
hot connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• First Traveler and Third Traveler wall box wire from dimmer in
the 3-way box to remote terminal screw marked "BK" in the
4-way box, and to the terminal screw marked "BK" of the
remaining remote in the 3-way box.
• Second Traveler (tagged) and Fourth Traveler (tagged) wall box
wire from dimmer in the 3-way box to remote terminal screw
marked "YL/RD" in the 4-way box, and to the terminal screw
marked "YL/RD" of the remaining remote in the 3-way box
(note
wire colors)
. This traveler from the remotes must go to the
terminal screw on the dimmer marked "YL/RD" or the Yellow/Red
dimmer lead.
• Line Neutral wall box wire to remote terminal screw marked
"WH".
WIRING MATChING REMOTE (3-Way wall box with Line
hot connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler dimmer terminal screw
marked "BK" or the Black dimmer lead.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked "YL/RD"
(note wire color as above)
. This traveler
from the remote must go to the terminal screw on the dimmer
marked "YL/RD" or the Yellow/Red dimmer lead.
• Line Neutral wall box wire to remote terminal screw marked