background image

FEATURES

• Leviton's Decora

® 

Style design

• Double Tap functions

• Soft fade ON/OFF

• Power interruption – load returns to existing state

• Minimum Brightness Adjustment

• ON/OFF LED indicates status of load

• Brightness Level Display

• Color conversion available

FCC COMPLIANCE STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) This
device must accept any interference received, including interference that may cause undesired operation.

INSTALLATION INSTRUCTIONS

WARNING:

 TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.

WARNING:

 

IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.

WARNING:

 

TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE,

FLUORESCENT LIGHTING, A MOTOR- OR A TRANSFORMER-OPERATED APPLIANCE OTHER THAN APPROPRIATE LOW-VOLTAGE LIGHTING.

CAUTION:

 USE WITH ELECTRONIC LOW-VOLTAGE TRANSFORMERS ONLY. 

DO NO

T USE TO CONTROL A MAGNETIC LOW-VOLTAGE TRANSFORMER. USE A

LEVITON MAGNETIC LOW-VOLTAGE DIMMER TO CONTROL MAGNETIC LOW-VOLTAGE TRANSFORMERS.

CAUTION:

 THIS DIMMER PROVIDES PROTECTION FROM OVERHEATING. IF MORE THAN THE RATED WATTAGE IS APPLIED, THE LOAD WILL SHUT OFF UNTIL

THE DIMMER COOLS DOWN AND RESETS. IF THIS SHOULD OCCUR, THE EXCESS LOAD MUST BE REMOVED TO RESUME PROPER OPERATION.

OTHER CAUTIONS:

1.

USE ONLY ONE (1) DIMMER IN A MULTI-LOCATION CIRCUIT. THE SWITCH(ES) WILL TURN THE LIGHT
ON AT THE BRIGHTNESS LEVEL SELECTED AT THE DIMMER. FOR MULTI-LOCATION APPLICATIONS,
USE MSEØR-1 REMOTE(S).

2.

DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING LAMPS.

3.

USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
DEVICES MARKED CO/ALR OR CU/AL.

MULTI-GANG INSTALLATION:

When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully bend
side sections back and forth until they break off 

(refer to Figure 1)

. The side sections dissipate heat, so

removing them requires a derating of the dimmer's capacity 

(refer to chart)

.

MAXIMUM BULB WATTAGE (For Electronic Low-Voltage Only):

Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is
determined by the efficiency of the transformer in the low-voltage lighting system.
Transformer efficiencies will vary from different manufacturers; consider 90% efficient as
average. Use the chart to determine maximum bulb wattage for typical transformer
efficiency ratings.

TO INSTALL:

1.

WARNING:

 

TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT

BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!

2.

Remove existing wallplate and switch or dimmer, if applicable.

3.

Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are
straight.

4.

Connect lead wires per appropriate WIRING DIAGRAM as follows: 

WARNING:

 CONNECT A

ELECTRONIC LOW-VOLTAGE DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A
ELECTRONIC LOW-VOLTAGE TRANSFORMER.

 Twist strands of each lead tightly and, with circuit

conductors, push firmly into appropriate wire connector 

(see chart for allowable wire connector and

number of conductor combinations)

. Screw connectors on clockwise making sure that no bare conductor

shows below the wire connectors. Secure each connector with electrical tape.

NOTE

: For single pole applications, cap YELLOW lead with an appropriate size wire connector. Secure

connector with electrical tape.

NOTE:

 This model incorporates a trim adjustment which will allow the installer to precisely set the low end of

the dimming range to suit each installation. This adjustment is preset at the factory and should require no
further adjustments for most installations. If adjustment is required proceed as follows, otherwise continue with
step 7:

5.

The brightness adjustment is located on the side of the dimmer 

(refer to Figure 1)

. Using a small, insulated

screwdriver, depress and hold the brightness adjustment switch. To increase the minimum brightness, press
the upper half of the rocker. To decrease the minimum brightness, press the lower half of the rocker.

For Technical Assistance Call:

1-800-824-3005 (U.S.A. Only)

1 800 405-5320 (Canada Only)

www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not
for the benefit of anyone else that this product at the time of
its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for two years
from the purchase date. Leviton’s only obligation is to correct
such defects by repair or replacement, at its option, if within
such two year period the product is returned prepaid, with
proof of purchase date, and a description of the problem to

Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
York 11362-2591 (In Canada send to Leviton Mfg. of
Canada Ltd., 165 Hymus Blvd., Point Claire, (Quebec),
Canada H9R 1E9).

  This warranty excludes and there is

disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in
accordance with any labels or instructions. There are no other
or implied warranties of any kind, including merchantability
and fitness for a particular purpose, but if any implied warranty
is required by the applicable jurisdiction, the duration of any
such implied warranty, including merchantability and fitness
for a particular purpose, is limited to two years. Leviton is not
liable for incidental, indirect, special, or consequential
damages, including without limitation, damage to, or loss of
use of, any equipment, lost sales or profits or delay or failure
to perform this warranty obligation. The remedies provided
herein are the exclusive remedies under this warranty,
whether based on contract, tort or otherwise.

DI-000-MDE03-00A

C O L L E C T I O N  B Y  L E V I T O N

              

Single Pole (One location) or

3-Way (Multi-location)

                           

Electronic Low-Voltage

       

Cat. No. MDEØ3-1

(w/brightness level display)

120VAC, 60Hz

 350VA

Total minimum wattage must

exceed 40W or 40VA

For use w/Cat. No. MSEØR-1 Multi-Remote™

INSTALLATION INSTRUCTIONS

       

  Two

  More than

      Cat. No.           Single          Gang

    2 Gang

     MDEØ3-1L

   350VA

    250VA

    200VA

MAXIMUM LOAD PER CONTROL FOR MULTI-GANG

           

  Two

   More than

            Rating               Single       Gang

  

   2 Gang

   

         350VA                 315W

  225W

   180W

MAXIMUM BULB WATTAGE AT 90% EFFICIENCY

DI-000-MDE03-00A

Upper

Rocker

Air Gap

Switch

ON/OFF

LED

Lower

Rocker

Minimum Brightness 

Adjustment Switch

Brightness Level

Display

Mounting Strap

Side Sections

Figure 1 – Dimmer Functions

WIRE CONNECTOR / # OF COND. COMBINATION CHART

1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 #14 w/ 1 #16 or #18
2- #12 w/ 1 #16 w/ 1 or 2 #18
2- #14 w/ 1 to 3 #16, #18 or #20
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 to 4 #16, #18 or #20
2- #14 w/ 1 to 3 #16, #18 or #20

2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
3- #14 w/ 1 or 2 #18 or #20
4- #14 w/ 1 #16 or #18
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
3- #14 w/ 1 #18 w/ 1 #20 or #22

DI-000-MDE03-00A

12/27/02, 4:14 PM

1

Reviews: