DESCRIPTION AND OPERATION

The RT-50 is a time switch that turns OFF the connected light or fan when the 
selected time expires. The light behind the ON/OFF button illuminates while the 
switch is OFF. One of the time button indicators is always lit to indicate the last 
used timer.

Manual ON

Turn ON the connected light or fan by pressing the desired time button, or the 
ON/OFF button. If you press the ON/OFF button, it activates the timer that was 
last used.

Manual OFF

While a timer is active, you can press the ON/OFF button to turn OFF the 
connected light or fan without delay. 

Changing the selected time

If you decide that you need more or less time than you originally selected, restart 
the time switch by pressing the button that matches the amount of time you think 
you’ll need.

RT- 50

Time Switch

7- Button Preset

   

6 time selection buttons with 
activation indicator lights

Lighted Switch
ON/OFF Button

SPECIFICATIONS

Voltage ....................................................................... 120VAC, 60HZ
Load (Single Pole Circuit)
 

Incandescent or fl uorescent lamp  ........................... 0 – 600 Watt

 Fan 

Motor 

............................................................................1/6HP

Time Delay...............................................1, 5, 10, 20, 30, 60 minutes
Environment .......................................... Residential Indoor use only
Operating Temperature ..............................32° to 131°F (0° to 55°C)
Humidity ....................................................95% RH, non-condensing
Tools Needed
 Insulated 

Screwdriver

 Wire 

Strippers

Santa Clara, CA 95050

Call 888.817.0571 for Technical Support

Содержание WattStopper RT-50

Страница 1: ... the ON OFF button to turn OFF the connected light or fan without delay Changing the selected time If you decide that you need more or less time than you originally selected restart the time switch by pressing the button that matches the amount of time you think you ll need RT 50 Time Switch 7 Button Preset 6 time selection buttons with activation indicator lights Lighted Switch ON OFF Button SPEC...

Страница 2: ... wires currently connected to the existing switch so that they can be identified later Disconnect the wires Make sure the insulation is stripped off the wires to expose their copper cores to the length indicated by the Strip Gage in Fig 2 approximately 1 2 inch 4 Wire the time switch Twist the existing wires together with the wire leads on the time switch as indicated in the drawing Cap them secure...

Страница 3: ... the indicator lights are ON Check the light bulb and or motor switch on the fan mechanism Make certain that the circuit breaker is ON and functioning Turn OFF power to the circuit then check wire connections Call 1 888 817 0571 for technical support Light or fan will not turn OFF Press the ON OFF button If connected light or fan does not turn OFF turn OFF power to the circuit then check wire conn...

Страница 4: ...a apagar sin retardo la lámpara o ventilador conectado Cambio del tiempo seleccionado Si usted decide que necesita más o menos tiempo con respecto al tiempo seleccionado originalmente reinicie el interruptor temporizado oprimiendo el botón de selección de Retardo de Apagado que coincide con la cantidad de tiempo que usted cree que se necesitará RT 50 Interruptor Temporizado Preajuste de 7 Botones ...

Страница 5: ... posteriormente Desconecte los alambres Asegúrese de remover el aislamiento de los alambres para exponer sus núcleos de cobre según la longitud indicada en la Figura 3 aproximadamente 1 2 pulg 4 Cablee el interruptor temporizado Empalme retorciendo los alambres existentes con los alambres del interruptor temporizado según se indica en el diagrama Fíjelos de manera firme utilizando los conectores wi...

Страница 6: ...inado y no hay luz indicadora de Retardo de Apagado Haga sombra sobre el interruptor para asegurarse que ninguna de las luces indicadoras del interruptor esté encendida Revise la bombilla y o el interruptor del motor en el mecanismo del ventilador Verifique que el cortacircuitos breaker esté encendido y funcionando Apague el suministro eléctrico hacia el circuito luego revise las conexiones de los ...

Отзывы: