1.   Introduction  

 

The lyriQ™ Standard Keypad, P/N AU7394-xx 

(see 

Figure 1

),

 is an integral part of 

the lyriQ™ Multi-Room Audio System. It is a component which, when combined with 
other essential components (a Source Input Unit, Distribution Module and Speakers) 
and your source equipment (receiver, CD player, etc.), creates a versatile whole-
house audio system that will fill your rooms with high-quality sound for years to 
come. It uses Category 5 wiring to distribute audio signals, control information and 
IR for remote control. The Keypad has two on-board class D amplifiers to provide a 
rich level of clean sound. It also contains a full set of features, including the 
integrated ability to control all other keypad volume controls in the house. It is 
available in White (-WH), Light Almond (-LA), Ivory (-IV), or Black (-BK). Build an 
audio system that accommodates the needs of any space by combining the lyriQ™ 
Standard Keypad with the lyriQ™ High Performance Keypad (AU1000-xx) in the 
same system. 

 
 

2.   Description  

 

The front panel of the lyriQ™ Standard Keypad 

(see 

Figure 1

),

 contains push 

buttons for VOLUME UP/DOWN (with five associated green Volume Bar Graph 
LEDs), SOURCE (with four green Source Selection LEDs) and MUTE (with one red 
status LED). There is also an IR target window and tri-colored status LED. 
 
The rear of the lyriQ™ Standard Keypad (see 

Figure 2

) contains an RJ45 jack (J1) 

for connection to the lyriQ™ Audio Distribution Module. The TB2 speaker output 
connections (left and right, plus and minus) are spring loaded and designed to 
support up to 14 gauge wire. The TB1 Line Out connections (left and right, plus and 
minus) are also spring loaded and designed to support up to 14 gauge wire. These 
connections can be used to attach a powered subwoofer such as On-Q’s 10” (P/N 
364664-01) or 12” (P/N 364671-01) subwoofer or an external amplifier.  
 

NOTE: The lyriQ™ Standard Keypad is recommended for indoor use only. 

    

3.   Installation  

 

Installation of the lyriQ™ Standard Keypad is best accomplished at multiple times 
during new construction, at “Rough-in” before the drywall is installed, and at “Trim-
out” after the drywall is installed and painted

 

NOTE: Before connecting the volume controls: Make sure that power supplies are not connected to the 
lyriQ™

 

Audio Modules. For instructions on pre-wiring and installing other components of the lyriQ™

 

Audio System, please see the Instruction Sheets included with those components. 
 
NOTE: Always follow TIA-570-B wiring standards for installing and terminating Category 5 cable. Failure to 
follow the correct wiring standard could result in damaged equipment and/or electrical interference issues. 
 
NOTE: Maintain a minimum 12” separation between Category 5 cable and any 120VAC cabling. 

 

Figure 1 

Figure 2 

Содержание lyriQ

Страница 1: ...EDs SOURCE with four green Source Selection LEDs and MUTE with one red status LED There is also an IR target window and tri colored status LED The rear of the lyriQ Standard Keypad see Figure 2 contai...

Страница 2: ...jack J1 see Figure 2 2 For the Line Out Speakers Out connections TB1 TB2 strip 3 8 of insulation from each of the four conductors and insert the appropriate wires into the appropriate connections see...

Страница 3: ...e 8 Zone Module cascade Single Source Modules To cascade a Single Source Module simply run a Category 5 jumper from the Cascade Out RJ45 jack on the front panel of the first Module to the Source In RJ...

Страница 4: ...wait for 10 second time out see Figure 5 NOTE When any Keypad button is tapped back light level goes to full bright and returns to the adjusted level when activity ceases For Remote operation the back...

Страница 5: ...nd then 2 and finally to 3 while double tapping it will cause every active keypad to go directly to Source 3 NOTE The Whole House Source Control mode will be exited when the user fails to press a key...

Страница 6: ...controlled from other keypads on the system that have engaged Whole House Mode Whole House Disable src 1 vol 2 turns off the ability of a keypad to be controlled by other keypads that have engaged Who...

Страница 7: ...of radiated interference IR Target Disabled for use when system is installed in environments that have extreme levels of radiated interference Nightlight Default src 1 3 vol 1 Keypad glows dimly when...

Страница 8: ...al source which requires a change Auto Off Enable Disable Default src 2 4 vol 1 Keypad will turn off after 20 minutes of no music Auto Off Disable src 2 4 vol 2 Keypad will remain on until manually tu...

Отзывы: