background image

1

Operating manual

TINY-FOGGER

New version

Summary of Contents for TINY-FOGGER

Page 1: ...1 Operating manual TINY FOGGER New version ...

Page 2: ...tice from the table of contents the manual for your new gadget is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we wish you a lot of fun when using your new TINY FOGGER ...

Page 3: ...liliters with quick connector and air valve 1 bottle of fluid 250 milliliter 4 T Clips for connecting the fluid tubing and the control cable When the order includes a radio remote the following items are supplied additionally 1 receiver with stereo jack 1 radio remote 1 manual Radio remote control Please check whether all the products you ordered are supplied ...

Page 4: ... Operating and Storing 4 3 Charging the Battery 4 4 Safety Instructions 4 5 Technical Data 5 The Charger 13 5 1 Operating the Charger 5 2 General Notes 5 3 Technical Data 6 Service and Maintenance 15 6 1 Changing the Vaporizer 6 1 1 Removal of the Vaporizer 6 1 2 Installation of the Vaporizer 6 1 3 Calibrating the Vaporizer 6 2 The machine does not work perfectly 6 2 1 There will be no fog if 6 2 ...

Page 5: ...20 milliamperes in idle status and consequently it may remain connected to the the battery for several hours with no discharging to speak of When emitting fog a strong current of 5 to 6 AMP runs with peak levels of 12 to 13 AMP The following sequence produces fog a Warming up 1 second without pumping fluid b The pump runs between 1 second and 2 minutes depending on application c Heat again 15 seco...

Page 6: ...of fluid do not generate the fog you require and destroy your fog generator Do not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot of water Consult a doctor should you have accidentally swallowed some fluid Spilled fluid or splashed fluid droplets can cause slip hazard Mop up the fluid and dispose of it according to regulations TINY FLUID is completely wate...

Page 7: ...ocation The location for the TINY FOGGER must be dry guarantee sufficient air supply have sufficient distance at least 30 cm from inflammable materials have very little vibration have an ambient operating temperature between 5 C and 45 C have a relative air humidity of less than 80 Start button Sockets for cable for the control panel and the radio remote ...

Page 8: ...e to the battery 4 Press start button at the control panel black briefly After approx 1 second the unit generates fog according to the fogging time preset by the factory Caution The wires in the fog nozzle must not be damaged Should these wires be damaged the unit will no longer work correctly when generating fog and the vaporizer must be changed see section 6 1 If the Tiny Fogger is to be built i...

Page 9: ... must be pressed and held down until the desired fogging time is achieved then release it This programmed fog amount can then be reproduced by briefly pressing the button on the control panel or the topmost button on the receiver of the radio remote You can reproduce the programmed fog amount in this manner as often as you like The programmed fogging duration will remain in memory until you progra...

Page 10: ...100 fog emissions of 4 5 seconds The permanent fogging time amounts to 10 minutes When used correctly the battery holds its capacity for several years and or some hundred charge discharge cycles Lead gel batteries are a very robust bank of capacitors which need little care and maintenance However their working life can be shortened rapidly by storing them when discharged Caution Do not store a dis...

Page 11: ...e of the battery will decrease the more the temperature rises Using the battery in closed units Don t use the battery in completely sealed casings or units To prevent a blast of hydrogen leaking from the battery the casings must be ventilated Dismantling the battery Don t dismantle batteries as they do contain electrolytes which may damage clothing or hurt the skin If the electrolyte comes in cont...

Page 12: ...arger 1 If the charge display does not light up after connecting it to the battery check the following points quality of the connections possible oxidation of the battery ends state of the battery a stored uncharged battery may become sulfated and can not hold a charge 2 If the control display lights up permanently this might indicate probable battery problems short circuit within the battery or i...

Page 13: ...End of charging at 13 8 V Temperature range 10 C to 35 C Isnsulation 4 kV between primary and second Setting regulated at 13 8 V preset Class of Insulation IP 40 Protection class II Case material Noryl SE 1 Dimensions 80 x 56 x 46 mm Display LED red charging display goes out at a charging current of 60 mA Weight 0 5 kg ...

Page 14: ...rmance declines con siderably and the vaporizer must be changed 6 1 1 Removal of the Vaporizer Separate the TINY FOGGER from the battery take off the battery clip Unscrew the two screws 5 with a suitable screwdriver No 1 Phillips Take off the casing cover Unplug the connector for pump cable 6 Now you can slide out the vaporizer 7 upwards Remove the blue fluid tubing 8 from tubing spout 9 of the va...

Page 15: ...ring the calibration process the vaporizer temperature must be at 20 C Never start fogging before the calibrating process Too cold or too warm units must first adapt to the room temperature 20 C With the battery disconnected press and hold down the blue button 11 at the back of the machine Connect the battery clip to the battery and then release the button The yellow LED battery status display wil...

Page 16: ... that the fluid tube is emptied It could be that some fluid drops come out of the nozzle and the surrounding gets wet and greasy the battery is discharged disconnect the machine from the battery and charge the battery the vaporizer is clogged or broken change the vaporizer see point 6 1 Note the new vaporizer must be calibrated as explained in point 6 1 3 6 2 2 The yellow LED lights permanently if...

Page 17: ... sec Fluid tan capacity 50 ml Fogging time programmable Continuous output with battery 10 min Temperature control microprocessor Control cable remote radio remote option Dimensions TINY L x W x H 91 x 34 x 51 mm Weight TINY approx 300 g Manufactured for Look Solutions made in Germany 7 Technical Data ...

Page 18: ...d or if spare parts are used which are nor approved by us The right of guarantee service is also lost if fluids other than the original TINY FOGGER FLUID have been used or if units are sent to us with full fluid bottles Also non compliance with the instructions in this manual or mistakes by incorrect handling treating of the machine will lead to a loss of guarantee and also any faults and damages ...

Reviews: