background image

1

Sensor-keypad with  

The LCN-GT6 (LCN-GTS6) is  a  6-key sensor-keypad for the T-Port.

The   integrated   temperature sensor can be used on
(Juni 2013) or after.

The sensor keys are each equipped with an additional status-LED and a blue background 
light. 

®

A  corona - surrounding light with white  LED´s, serves as 
a  decorative  wall  light  (LCN-NUI  required)  and  can  be 
switched as a decent orentation light, so that the LCN-
GT6  (LCN-GTS6) can also be operated in darkness.

The  6  capacitive  working    sensor  keys  are  situated 
behind  a  5mm  thick  glass  front.    A    soft  touch  to  the 
surface  is  enough  to  trigger  off  the  functions.    The 
captions on the sensor keys can be carried out individual-
ly per inlay and can be changed anytime  without difficulty. 

6 keys and  temperature sensor

 LCN modules with 1706.. firmware   

LCN-GTS6

®

  Installation guide 

LCN-GT6

®

A1

L1

A2

L2

A3

L3

A4

L4

A5

L5

A6

L6

Summary of Contents for LCN-GTS6

Page 1: ...NUI required and can be switched as a decent orentation light so that the LCN GT6 LCN GTS6 can also be operated in darkness The 6 capacitive working sensor keys are situated behind a 5mm thick glass front A soft touch to the surface is enough to trigger off the functions The captions on the sensor keys can be carried out individual ly per inlay and can be changed anytime without difficulty 6 keys ...

Page 2: ...ouble touching is especially suitable for functions that should not be accidentally triggered central off switching the alarm system etc The integrated temperaturesensor supplies the measured values with a triggering from 0 1 C and thanks to its adaptive average calculation practically noiseless The 6 Status LED s in the sensor areas are individually controlled over the T Port and configuredover t...

Page 3: ...nal LCN GRT The LCN GT6 must not wobble on the wall as this would lead to false triggering That is why when installing the edges of the cavity wall mounted box should be counter sunk or the flush mounted box should not be surmounted on the wall to guarantee a flawless function of the LCN GT6 LCN GTS6 Corona surrounding light O Light Orientation light and the blue key Note Important When the temper...

Page 4: ...ssigned in the LCN PRO menu Ports The assignments can be comfortably chosen as graphics For example each line of 3 keys can be changed into 2 larger keys see the lower example Important functions can be easily operated without losing the flexibility of many keys T Ports Change mapping LCN GT6 LCN GTS6 will be automatically recognized from the module and the temperature registered in the variable 3...

Page 5: ... the connected UP x module onto the wall At the bottom area the LCN GT6 must be hooked into the corners of the mounting frame and pressed towards the wall Through pushing in the plastic slider on the side the LCN GT6 is locked firmly onto the mounting frame LCN GT6 LCN GTS6 Installation LCN GTS6 Installation guide LCN GT6 IG1 LCN ISSENDORFF Oben adjusting the mounting frame green help for insertio...

Page 6: ... ideal luminance of the status LED s Inserting the inlay into the key sensor Pull the plastic slide to the side outwards at the rear of the key sensor Insert the inscripted inlay at the bottom side of the LCN GT6 LCN GTS6 into the groove until it resists Tip If you cut off the corners of the inlay around 2 mm it will make it easier for inserting the inlay into the groove When changing the paper re...

Page 7: ... to the I Port of any module with year of manufacture 2013 or later and supplies theT Port over the module The brightness of the status LED s as well as the Corona surrounding light can be reduced for the night operation with the command LED control LED brightness Captions for the keys using ordinary paper and operation without an LCN NUI make the LED s harder to recognise by direct exposure to li...

Page 8: ...ey background LED s blue funktions OFF ON white corona LED s controllable over command GT brightness adjustable in steps temperature sensor measurement range Installation dimensions W x H x D 90mm x 90mm x 12 5mm 5mm glass thickness LCN GT6 75mm x 75mm x 10 5mm 3mm glass thickness LCN GTS6 operating temperature 10 C to 50 C air humidity max 80 rel non condensing environmental conditions use as sta...

Reviews: