background image

 

 
 
 

WS-7014U 

Wireless 433 MHz 

Radio-controlled Weather Station 

 

Instruction Manual

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

Summary of Contents for WS-7014U

Page 1: ...WS 7014U Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Page 2: ...ing 8 9 Time Setting WWVB Manual 9 10 Setting Day Date and Year 10 11 Selecting F or C 11 Setting the LCD Contrast 11 12 Features Weather Forecast Icons 12 13 Indoor Temperature Humidity Comfort Level...

Page 3: ...continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal antenna in the Weather Station However due to the nature of the Earth s Ionos...

Page 4: ...shaded area The remote sensor has a range of 80 feet Any walls that the signal will have to pass through will reduce distance An outdoor wall or window will have 20 to 30 feet of resistance and an int...

Page 5: ...hen push up and pull out on the battery cover 2 Observe the correct polarity and install 2 AA batteries 3 Replace the battery cover Note Immediately after the batteries have been installed the LCD Liq...

Page 6: ...6 correct time default time zone is Eastern You will need to adjust the time zone to match your local time...

Page 7: ...hat setting I FUNCTION KEYS The function keys are located on the front of the unit directly below the LCD II 12 OR 24 HOUR TIME SETTING 1 Press and hold the SET button for 3 seconds or until 12 h flas...

Page 8: ...concerned with the ones in the chart above 4 Press and release the SET button to confirm and advance to the Daylight Saving Time setting IV DAYLIGHT SAVING TIME DST SETTING 1 Press and hold the SET bu...

Page 9: ...nd overrides any manually set time The WWVB tower icon appearing in the TIME LCD will flash when a signal search is in progress and a signal is being received and will remain steady when the signal ha...

Page 10: ...ton for 3 seconds or until 12 h or 24 h flashes in the DATE LCD 2 Press and release the SET button 5 more times to reach the Weekday setting mode Note MO representing Monday is the default setting for...

Page 11: ...4 Press and release the CH button to shift F to C and back 5 Press the SET button to confirm your selection and to advance to the LCD contrast setting VIII SETTING THE LCD CONTRAST 1 Press and hold t...

Page 12: ...forecasting for 12 24 hours after the unit has been set up reset or moved from one altitude to another i e from one floor of a building to another floor In areas where the weather is not affected by...

Page 13: ...ncy arrows one that points up on the left side of the LCD and one that points down on the right side of the LCD These arrows reflect current changes in the air pressure An arrow pointing up indicates...

Page 14: ...MPERATURE RECORDS 1 Press the IN button once MIN appears in the upper center location of the flashing INDOOR LCD indicating that the minimum temperature along with the humidity measured at that time a...

Page 15: ...IMUM RECORDS 1 All the Indoor records minimum and maximum will be reset after the IN button is pressed and held for 5 seconds 2 All the Outdoor records minimum and maximum will be reset after the OUT...

Page 16: ...to the Indoor Temperature Station 6 Follow the Detailed Set Up Guide for programming and operating instructions B VIEWING AND OPERATING WITH MULTIPLE REMOTE CONTROL SENDER UNITS 1 To view the temperat...

Page 17: ...outside North facing wall The sending range is 80ft obstacles such as walls concrete and large metal objects can reduce the range Place both units in their desired location and wait approximately 10 m...

Page 18: ...STATION The Indoor Temperature Station can be mounted in two ways with the table stand or on the wall with the use of a wall hanging screw not included A USING THE TABLE STAND 1 The Indoor Temperatur...

Page 19: ...19...

Page 20: ...ol Sender and Weather Station in position so the straight line signal is not passing through more than two or three walls Problem Temperatures do not match if units are placed next to each other Solut...

Page 21: ...displays and units with a soft damp cloth Do not use solvents or scouring agents they may mark the displays and casings Do not submerge in water Immediately remove all low powered batteries to avoid l...

Page 22: ...Temperature checking interval Every 10 seconds Indoor Humidity checking interval Every 1 minute Outdoor Temperature checking interval Remote Control Sender Every 1 minute Outdoor Temperature reception...

Page 23: ...d for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Tec...

Page 24: ...nformation contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossetechnology com inform...

Reviews: