manualshive.com logo in svg
background image

Alizé Weather Station (Standard Version) 

Model: BAR266

User Manual

  

EN

 

 cES AMONG thN129h

OVERViEW
FRONt ViEW

1

2

3

4

5

1.  Ice alert indicator

2.  + - Press to increase settings, press and hold to increase 

settings rapidly

3.    - Press to toggle between the clock and calendar, press 

and hold to enter the setting mode

4. 

MEM

 – Press to toggle the current/maximum/minimum 

indoor/outdoor temperature and indoor humidity records, 

press and hold to clear the MAX/MIN records

5.  – - Press to decrease settings, press and hold to decrease 

settings rapidly. Press and hold to turn off the ice alert

tOP ViEW

1

2

3 4 5

1. 

SENSOR

 – Press to toggle between indoor sensor and 

channel 1-5, turn on or off auto-loop. Press and hold to 

search for the sensor for all channels

2. 

LiGht

 – Press to turn on the backlight 

3. 

Rcc

 – Press to turn on and toggle EU/UK/US RCC 

function, press and hold to turn off RCC function

4. 

°c/°F

 - Press to toggle the desired temperature unit

5. 

RESEt

 – Press to reset all settings to default

tOP ViEW

1

2

1.  Battery compartment

2.  Battery compartment cover

LcD DiSPLAY ScREEN

 

 

1

2 3 4 5 6 7

8

9

10

11

12

13

14

15

16

17

1.  Weather forecast display

2.     RCC Clock reception signal indicator

3. 

MAX/MiN

 temperature indicator

4.  Outdoor sensor low battery display

5.     Remote sensor reception indicator

6.     Temperature auto-loop indicator

7.   Outdoor sensor channel number 

8.  Main unit low battery display

9.  Indoor/outdoor temperature

10. Temperature trend indicator

11. Indoor/outdoor temperature unit display (

°c/°F

)

12. Humidity trend indicator

13. Humidity reading display

14. Date/month format display (date: month/month: date)

15. Time/Calendar

16. 

AM/PM

17. Weekday display

REMOtE SENSOR (thN132N)

 

  

2

3

4

5

1

1.  LED status indicator

2.  Wall mount hole

3.  Battery compartment

4. 

RESEt

 hole

5. 

chANNEL

 switch

NOtE

 The sensor included in this package can search 

channels 1, 2 and 3. To search all 5 channels, you may 

purchase additional sensors. Visit www.oregonscientific.com 

for more about accessory sensors.

GEttiNG StARtED
iNSERt BAttERiES

1.  Gently pull the battery compartment cover apart from the 

unit.

2.  Insert the batteries, matching the polarities (+/-).

3. Press 

RESEt

 after each battery replacement.

 

LOcAtiON

MEANiNG

Sensor batteries are low
Main unit batteries are low

NOtE

 Replace the batteries when 

  displays , or when 

the display/backlight is dim.

REMOtE SENSOR 

The main unit can collect data from up to 5 sensors.

To set up the sensor:

1.  Open the battery compartment.

2.    Insert the batteries, matching the polarities (+/-).

3.  Select a channel then press 

RESEt

.

4.  Close the battery door.

5.  Place the sensor within 30 m (98 ft) of the main unit using 

the table stand or wall mount.

tiP

 Ideal placements for the sensor would be in any location on 

the exterior of the home at a height of not more than 1.5m (5ft) 

and which can shield it from direct sunlight or wet conditions 

for an accurate reading.

1.5 m (5 ft)

 NOtE 

 Use alkaline batteries for longer usage and consumer 

grade lithium batteries in temperatures below freezing.

SENSOR DAtA tRANSMiSSiON

to search for a sensor:

Press and hold 

.

The sensor reception icon in the remote sensor area shows 

the status:

icON

Doscription

Searching for sensor(s).

Sensor is found.

Cannot find sensors.

tiP

 The transmission range may vary depending on many 

factors. You may need to experiment with various locations 

to get the best results.

cLOcK
cLOcK REcEPtiON

This clock is designed to synchronize its clock automatically 

with a clock signal. Press 

 to turn on and select the desired 

region (EU/UK/US).

Region

Signal

EU

DCF

UK

MSF

US

WWVB

Clock signal reception indicator:

icons

Description

M a i n   u n i t   i s 

searching for 

c l o c k   s i g n a l 

strength

(flash)

M a i n   u n i t   i s 

searching for 

clock signal 

No clock signal

NOtE

 It takes 2-10 minutes to receive the clock signal. If 

the signal is weak, it could take up to 24 hours to receive a 

valid signal.

You may turn off the clock signal reception and set the clock 

manually.

to disable signal reception:

Press and hold 

. The   icon turns off.

NOtE

 The signal reception is on after each reset or battery 

replacement. 

SEt thE cLOcK MANUALLY

1.  Press and hold  

  to disable signal reception.

2.  Press and hold  . The screen displays 

ZONE

 and the 

number flashes.

3.  Press once or press and hold +/- to adjust the setting. For 

EU/UK, the time-zone offset sets the clock up to +/- 23 hours 

from the received clock signal time. For US, the time-zone 

setting is 

0

(P), 

1

(M), 

2

(C), 

3

(E).

4. Press 

 to confirm. 

5.  Press once or press and hold + / - to adjust the setting for 

12/24h hour format, hour, minute, year, calendar format 

(month-day/day-month), month, date and language. 

6. Press 

 to confirm each setting.

NOtE 

The language options are English (

ENG

), Spanish 

(

SPA

), Italian (

itA

), French (

FRE

) and German (

GER

).

When the unit is in idle mode, you may choose the display 

mode options.
To 

select the display mode:

Press   to select between clock and date display.

WEAthER FOREcASt

This product forecasts the next 6 hours of weather within a 

19-31 mile (30-50 km) radius.

Screen display

Description

Sunny

Cloudy

Rainy

Snowy

tEMPERAtURE AND hUMiDitY

to toggle temperature unit:

Press 

°c / °F

 inside the battery compartment.

NOtE

 When the indoor temperature is lower than -5 °C (23.0  °F), 

the screen displays 

LL.L

. When the temperature is higher than 

50 °C (122.0 °F), the screen displays 

hh.h

.

to toggle sensor display:

Press 

 . 

to auto-loop between sensors:  

Press 

  repeatedly until the unit displays   . The data 

on each sensor displays for 3 seconds. Press 

  again 

turn off the auto-loop, the   icon turns off.

NOtE

 The sensor displays in ascending order. If not all 

5 sensors are present, the main unit skips the absent sensor 

and advances to the next present sensor.

to toggle 

MAX/MiN and current records between the main 

unit and the selected sensors:

Press 

MEM

 repeatedly.

to clear the MAX/MiN records:

Press and hold

 MEM

. All MAX/MIN data of indoor and outdoor 

temperature and indoor humidity will be cleared and starts to 

record the current readings.

icE WARNiNG

If the channel 1 sensor temperature falls between 3 °C to -2 °C 

(37 °F to 28 °F), LED indicator will flash, and will stop flashing 

once the temperature is out of this range. Press and hold 

to 

turn off the ice warning alert.

NOtE

 The ice warning alert turns on again when the 

temperature falls into the temperature range.

BAcKLiGht

Press 

 to turn on the backlight. The backlight will be on 

for 5 seconds.

PREcAUtiONS

•  Do  not  subject  the  unit  to  excessive  force,  shock,  dust, 

temperature or humidity.

•  Do not immerse the unit in water. If you spill liquid over it, 

dry it immediately with a soft, lint-free cloth.

•  Do not clean the unit with abrasive or corrosive materials.

•  Do  not  tamper  with  the  unit’s  internal  components.  This 

invalidates the warranty.

•  Only use fresh batteries. Do not mix new and old batteries.

•  Images  shown  in  this  manual  may  differ  from  the  actual 

display.

•  When  disposing  of  this  product,  ensure  it  is  collected 

separately for special treatment.

•  Placement  of  this  product  on  certain  types  of  wood  may 

result in damage to its finish for which Oregon Scientific will 

not be responsible. Consult the furniture manufacturer's care 

instructions for information.

•  The contents of this manual may not be reproduced without 

the permission of the manufacturer.

•  Do not dispose old batteries as unsorted municipal waste. 

Collection of such waste separately for special treatment is 

necessary.

•  Please note that some units are equipped with a battery 

safety strip. Remove the strip from the battery compartment 

before first use.

NOtE

 The technical specifications for this product and the 

contents of the user manual are subject to change without 

notice.

SPEciFicAtiONS
MAiN UNit

L x W x H

156 x 82 x 19 mm

(6.1 x 3.2 x 0.7 in)

Weight

158 g (5.6 oz) 

Temperature range

-5°C to 50°C (23°F to 122°F)

Resolution

0.1°C (0.2°F)

Accuracy

0°C-40°C: ±1°C (± 2.0°F)

40°C <T<0°C: ±2°C (± 4.0°F)

Power

2 x UM-4 (AAA) 1.5 V 

batteries

REMOtE UNit (thN132N)

L x W x H

96 x 50 x 22 mm

(3.78 x 1.97 x 0.87 in)

Weight

50 g (1.76 oz) without 

batteries

Transmission range

30 m (98 ft) unobstructed

Temperature range

-20 °C to 60 °C

(-4 °F to 140 °F)

Relative humidity 

measurement

25% RH - 95% RH

Humidity accuracy

±8% (20%~90%)

Signal frequency

433 MHz

Power

1 x UM-3 (AA) 1.5 V 

batteries

ABOUt OREGON SciENtiFic

Visit our website www.oregonscientific.com to learn more about 

Oregon Scientific products. 

For  any  enquiry,  please  contact  our  Customer  Services  at 

[email protected]

Oregon Scientific Global Distribution Limited reserves the right 

to interpret and construe any contents, terms and provisions 

in this user manual and to amend it, at its sole discretion, at 

any time without prior notice. To the extent that there is any 

inconsistency between the English version and any other 

language versions, the English version shall prevail. 

Fcc StAtEMENt

This device complies with Part 15 of the FCC Rules. Operation 

is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) This device must 

accept any interference received, including interference that 

may cause undesired operation.

WARNiNG

 Changes or modifications not expressly approved 

by the party responsible for compliance could void the user's 

authority to operate the equipment.

NOtE

 This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a 

residential  installation.This  equipment  generates,  uses  and 

can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is 

no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference 

to radio or television reception, which can be determined by 

turning the equipment off and on, the user is encouraged to 

try to correct the interference by one or more of the following 

measures:

•  Reorient or relocate the receiving antenna.

•  Increase  the  separation  between  the  equipment  and 

receiver.

•  Connect the equipment into an outlet on a circuit different 

from that to which the receiver is connected.

•  Consult the dealer or an experienced radio/TV technician 

for help.

This Class B digital apparatus complies with Canadian 

ICES- 3(B)/NMB-3(B)

cLOcK REcEPtiON

The following information is not to be used as contact for 

support or sales. Please call our customer service number 

(listed on our website at www.oregonscientific.com.  or on the 

warranty card for this product) for all inquiries instead.

We,
Name:                      Oregon Scientific, Inc.
Address:                  10778 SW Manhasset Dr.
                                Tualatin, Or 97062 USA
Telephone No.:        1-800-853-8883
declare that the product
Product No.:             BAR266
Product Name:         Alizé Weather Station 
                                 (Standard Version)
Manufacturer:           IDT Technology Limited
Address:                   Block C, 9/F, Kaiser Estate,
                                 Phase 1, 41 Man Yue St.,
                                 Hung Hom, Kowloon,
                                 Hong Kong

EU-DEcLARAtiON OF cONFORMitY

Hereby, Oregon Scientific, declares that this Alizé Weather 

Station (Standard Version) (model: BAR266) is in compliance 

with the essential requirements and other relevant provisions 

of Directive 1999/5/EC. A copy of the signed and dated 

Declaration  of  Conformity  is  available  on  request  via  our 

Oregon Scientific Customer Service.

 

cOUNtRiES RttE APPROVED cOMPLiED

All EU countries, Switzeriand

  ch

and Norway

    N

v

 

Estación Meteorológica Alizé 

(Versión Estándar) 

Modelo: BAR266

Manual de usuario

  

ES

 

 cES AMONG thN129h

DEScRiPciÓN GENERAL
ViStA FRONtAL

1

2

3

4

5

1.  Indicador de alerta de helada

2.  + - Pulse este botón para incrementar los valores de los 

parámetros, o manténgalo pulsado para incrementarlos con 

más rapidez.

3.      - Pulse este botón para mostrar el reloj o el calendario 

y manténgalo pulsado para acceder al modo de ajustes.

4. 

MEM

  – Pulse este botón para alternar entre la temperatura 

actual/máxima/mínima interna y externa, y los registros 

de humedad interna. Manténgalo pulsado para borrar los 

registros máximos y mínimos. 

5.  – - Pulse este botón para reducir los valores de los 

parámetros, o manténgalo pulsado para reducirlos con más 

rapidez. Manténgalo pulsado para desactivar la alerta de 

helada.

ViStA SUPERiOR

1

2

3 4 5

1. 

SENSOR

 – Pulse este botón para seleccionar el sensor 

interno o uno de los canales del 1 al 5, o bien para activar/

desactivar el modo de escaneo automático. Manténgalo 

pulsado para buscar el sensor de cada uno de los canales.

2. 

LiGht

 – Pulse este botón para activar la luz de fondo. 

3. 

Rcc

 – Pulse este botón para seleccionar la función RCC 

para EU, UK o US. Manténgalo pulsado para desactivar la 

función RCC.

4. 

°c/°F

 - Pulse este botón para seleccionar la unidad de 

temperatura deseada.

5. 

RESEt

 – Pulse este botón para resetear todos los ajustes 

a los valores predeterminados de fábrica.

ViStA tRASERA

1

2

1.  Compartimento de las pilas

2.  Tapa del compartimento de las pilas

PANtALLA LcD

 

1

2 3 4 5 6 7

8

9

10

11

12

13

14

15

16

17

1.  Pronóstico meteorológico

2.     Indicador de la recepción de la señal horaria RCC

3.  Indicador de temperatura 

MAX/MiN

4.  Icono de pilas bajas del sensor externo

5.     Icono de la recepción de la señal del sensor externo

6.     Indicador de escaneo automático de la temperatura

7.  Número de canal de sensor externo 

8.  Icono de pilas bajas de la unidad principal

9.  Temperatura interna y externa 

10. Indicador de la tendencia de la temperatura

11. Icono de la unidad de temperatura interna/externa (

°c/°F

)

12. Indicador de la tendencia de la humedad

13. Lectura de la humedad

14. Indicador del formato del día del mes/mes (día del mes : 

mes; mes : día del mes)

15. Hora/fecha

16. 

AM/PM

17. Día de la semana

SENSOR REMOtO (thN132N)

  

2

3

4

5

1

1.  Indicador LED de estado

2.  Agujero para instalación en pared

3.  Compartimento de las pilas

4.  Agujero de reseteo (

RESEt

)

5.  Selector de canal (

chANNEL

)

NOtA

 El sensor incluido con la unidad puede buscar los 

canales 1, 2 y 3. Vd. puede comprar sensores adicionales 

para buscar los 5 canales. Visite www.oregonscientific.com 

para más información acerca de los sensores accesorios.

GUÍA DE iNiciO
iNStALAciÓN DE LAS PiLAS

1.  Abra la tapa del compartimento de las pilas con cuidado.

2.  Inserte las pilas haciendo coincidir las polaridades (+/-).

3. Pulse 

RESEt

 cada vez que cambie las pilas. La unidad se 

enciende automáticamente.

 

UBicAciÓN

SiGNiFicADO

Las pilas del sensor están 

bajas

Las pilas de la unidad 

principal están bajas

NOtA

 Reemplace las pilas cuando aparezca  

  o cuando 

la pantalla / retroiluminación se atenúe.

SENSOR REMOtO 

La unidad principal puede recoger datos de hasta 5 sensores.

cómo instalar un sensor:

1.  Abra el compartimento de las pilas.

2.  Inserte las pilas haciendo coincidir el sentido de la 

polaridad (+/-).

3.  Seleccione un canal y pulse 

RESEt

.

4.  Cierre la tapa del compartimento de las pilas.

5.  Coloque el sensor a 30 m (98 pies) de la unidad principal 

utilizando la pata de apoyo o montándolo en la pared.

cONSEJO

 Para obtener una lectura precisa, procure colocar 

el sensor en un lugar al aire libre a una altura igual 1,5 m 

(5 pies) y donde esté protegido de la luz directa del sol o 

la lluvia.

1.5 m (5 ft)

NOtA

 Utilice pilas alcalinas para un uso más prologando, o 

pilas de litio para temperaturas bajo cero.

tRANSMiSiÓN DE LOS DAtOS DEL SENSOR

Para buscar un sensor:

Mantenga pulsado 

.

El icono de recepción de la señal del sensor remoto mostrará 

su estado:

icono

Descripción

Buscando sensor(es).

Se ha encontrado el 

sensor.

No puede encontrar 

sensores.

cONSEJO

 El alcance de la transmisión puede variar en 

función de muchos factores. Pruebe a colocar el sensor 

en  varios  lugares  hasta  que  obtenga  unos  resultados 

satisfactorios.

RELOJ
REcEPciÓN DE LA hORA

Este reloj está diseñado para sincronizar la hora con la señal 

horaria automáticamente. Pulse 

  para activar la función 

y seleccionar una región (EU/UK/US).

Región

Señal

EU

DCF

UK

MSF

US

WWVB

Indicador de recepción de la señal horaria:

iconos

Descripción

La unidad princi    

pal está detectando 

la intensidad de la 

señal horaria

(parpadeando)

La unidad principal 

está buscando una 

señal horaria 

No se ha encontrado 

una señal horaria

NOtA

 La recepción de la señal puede tardar de 2 a 10 minutos 

en establecerse. Si la señal es débil, puede tardar hasta 24 horas 

en recibir una señal válida.

P/N: 300103772-00001-10 REV1.0 

2

3

Отзывы: