background image

 

 

 

 

 

 

 

 

 

 

 

 

PCIe Medical LAN Card 

User’s Guide 

(Version 1.00)  

0-0096-4514 

 

If it’s embedded, it’s Kontron. 

Summary of Contents for 0-0096-4514

Page 1: ...PCIe Medical LAN Card User s Guide Version 1 00 0 0096 4514 If it s embedded it s Kontron...

Page 2: ...This page is intentionally left blank If it s embedded it s Kontron...

Page 3: ...d Product Identification 8 6 Product Description 9 6 1 Features 10 6 1 1 Network Features 10 6 1 2 Performance Features Supported by Intel 82574L LAN Controller 10 6 2 LAN Port s 11 6 3 Status LEDs 12...

Page 4: ...w profile slot bracket 8 Fig 4 Single low profile slot bracket 8 Fig 5 PCIe Medical Dual LAN Card top side 9 Fig 6 PCIe Medical Dual LAN Card bottom side 9 Fig 7 PCIe Medical Single LAN Card Dual top...

Page 5: ...or this reason Kontron Embedded Computers expressly informs the user that this manual only contains a general description of technical processes and instructions which may not be applicable in every i...

Page 6: ...symbol indicates general information about the product and the user manual This symbol precedes helpful hints and tips for daily use Microsoft MS DOS Windows and Windows NT are registered trademarks o...

Page 7: ...yond that provided by law This applies to the batteries for example 3 2 Exclusion of Accident Liability Obligation Kontron Embedded Computers shall be exempted from the statutory accident liability ob...

Page 8: ...d the systems power cord is disconnected from the mains power Disconnect all cable connections of peripheral devices from the system Ensure that the DC operating voltages adheres to the specification...

Page 9: ...radio communications Operation of this equipment in residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Engl...

Page 10: ...PCIe Medical Dual LAN card Fig 2 Single LAN PCIe Medical LAN Card Fig 3 Dual low profile slot bracket Fig 4 Single low profile slot bracket 5 1 Type Label and Product Identification Card Type Product...

Page 11: ...al top side Fig 8 PCIe Medical Single LAN Card bottom side The shield of the ethernet cable is isolated to ground earth at the LAN interface from PCIe Medical LAN Card Single or Dual Therefore the shi...

Page 12: ...ions Multi speed operation 10 100 1000 Mb s Full duplex operation at 10 100 1000 Mb s Half duplex operation at 10 100 Mb s Flow control support compliant with the 802 3X specification MAC address filt...

Page 13: ...D1 3 D2 4 D3 5 D3 6 D2 1 8 7 D4 8 D4 The shield of the ethernet cable is isolated to ground earth at the LAN interface from PCIe Medical LAN Card Single or Dual Therefore the shield of the ethernet ca...

Page 14: ...LED A yellow LAN 1 status no Link Link no Activity Link and Activity LED B yellow LAN 1 Speed 10Mb s 100Mb s 1Gb s LED C yellow LAN 2 status no Link Link no Activity Link and Activity LED D yellow LA...

Page 15: ...ND power Ground 5 SMCLK NC SMBus Clock JTAG2 I NC TCK clock input for JTAG interface 6 SMDAT NC SMBus Data JTAG3 I NC TDI 7 GND power Ground JTAG4 O NC TDO 8 3 3V power 3 3V power JTAG5 I NC TMS 9 JTA...

Page 16: ...Ie Medical Dual Single LAN Card is a low profile half length and haft height card with standard or low profile included brackets which offers flexibility in the configuration and expansion of a comput...

Page 17: ...with Intel Pentium III comparable an available PCIe slot e g x1 x4 x8 and x16 compliant with PCIe bus specification 2 0 which allows the system expansion a CD ROM drive corresponding cables Operating...

Page 18: ...4 x8 or x16 for system extension In order to install the PCIe Medical LAN Card Dual Single follow these steps 1 Shut down your application 2 Turn off the computer and the peripherally devices printers...

Page 19: ...ethernet cable shall be connected to ground or earth on the peripheral side f e LAN hub or ethernet switch EMC disturbances as high frequent transients Burst have an influence of the LAN transmission...

Page 20: ...te 250 MByte s per direction Data Transfer Rate 10 100 1000 Mb s Mechanical Dimension PCB Delivered with standard slot bracket attached 168 15mm half length x 68 9mm half height 6 62 half length x 2 7...

Page 21: ...cal Safety Harmonized Standards EUROPE Information technology equipment Safety Part 1 General requirements EN 60950 1 2006 U S A CANADA UL 60950 1 2006 cULus recognized EMC Harmonized Standards EU Gen...

Page 22: ...Material Authorization by Fax 49 8165 77 412 E mail service kontron com 2 Make sure to receive an RMA number from Kontron Embedded Computers Service before returning any merchandise Clearly write or...

Reviews: