background image

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   

 

 

 

KILOTECH

 

 

KWS 2200 

 

Weighing scale 

 
 
 

Operation Manual 

 
 
 
 
 

V5.13 

 
 
 
 
 

                    Contents Subject to Change without Notice 

──────────────────────────────────────────────

                                                                                                                                                                                                                                     

KILOTECH INC. 

www.kilotech.com     

 

Summary of Contents for KWS 2200

Page 1: ...KILOTECH KWS 2200 Weighing scale Operation Manual V5 13 Contents Subject to Change without Notice KILOTECH INC www kilotech com ...

Page 2: ...1 Ce manuel est disponible en français à www kilotech com ou auprès de notre service à la clientèle au 1 800 694 4445 Ce manuel est disponible en Spanish à www kilotech com ou auprès de notre service à la clientèle au 1 800 694 4445 ...

Page 3: ...ounts compare 11 10 Percent Weighing Mode 12 11 Check Percent percentage compare 13 12 BMI Working Mode 13 13 HOLD Function 14 14 Data Compare Function 15 15 Accumulation 16 16 View or Set Time 17 17 View or Set Date 17 18 View Firmware Version 17 19 Display Test 17 20 Keyboard and Buzzer Test 17 21 Enter Setup Mode 18 22 UPS world ship 18 23 Error codes and Troubleshooting 18 24 Troubleshooting 2...

Page 4: ...up time Turn the scale on and wait for a few minutes if possible to give the internal components a chance to stabilize before weighing These electronic scales are precision instruments Do not operate near an in use cell phone radio computer or other electronic device These devices emit RF and can cause unstable scale readings If your scale ever performs poorly try moving the scale to a different r...

Page 5: ...ically after 10s AC Adapter 6 9VDC 500mA central positive USB power supply 1 3 Real Clock built in nonvolatile real time date 1 4 Programmable settings 1 4 1 pre set tare weight 1 4 2 motion detection window 1 4 3 auto power off time 1 4 4 backlight working mode 1 4 5 hold function peak weight dynamic weighing 1 4 6 Check Weighing Mode Counting Mode Percentage Working Mode 1 4 7 Data Comparison an...

Page 6: ... with 16 annunciators and blue backlight 1 6 Keypad 6 push buttons 1 7 Environment 1 7 1 Working temperature 10 C to 40 C 1 7 2 Storage temperature 20 C to 70 C 1 7 3 Humidity 10 to 80 RH without condensation 1 8 Communication 1 8 1 Serial port0 Full duplex RS232 1 8 2 Serial port1 USB Virtual RS232 1 8 3 Baud Rate Selectable 1200 2400 4800 9600 19200 38400 bps 1 8 4 Data Output Format 8N1 7O1 7E1...

Page 7: ... lights up when measure unit is kg 2 8 lights up when in percentage weighing mode measure unit is 2 9 Pcs lights up when in counting mode measure unit is pieces 2 11 PEAK lights up when PEAK HOLD is active 2 12 HOLD lights up when HOLD mode is active 2 13 HI lights up when data compare is activated and current data weight pieces or percent is over the upper setting limitation 2 14 OK lights up whe...

Page 8: ... up current weight pieces percentage to memory display times and total of accumulation in BMI working mode to input height Weighing Counting Percent press down 3s ACCUMULATION function is enabled in configuration menu To display times and total of accumulation Input data mode the digit on flashed position subtract 1 Menu selection mode To Next item of current menu UINT DATA Weighing mode press dow...

Page 9: ...o to next item of current menu or next operation Display ADC code Set or clear tare code ZERO ON OFF Power off mode Power on Weighing Counting Percent press down 3s Zero function Weighing Counting Percent press down 3s Power off Input data mode ignore modification Menu selection mode Prepare to exit from current working mode Note To access the secondary key function you must press it for more than...

Page 10: ...RE weight mode use to input tare weight There s no limitation to preset tare weight but must be greater than zero Once you complete the setting of the tare weight the NET annunciator will be lighted Note you can only store one tare weight the new tare weight will automatically replace the old one 5 6 Clear tare weight remove all weight from the scale and short press TARE key 5 7 Limitation to ZERO...

Page 11: ...as no limitation 7 5 After the limitations have been set and check weight function is be active one of annunciators HI OK LO will light up and the beeper will sound according to its setting in USER BEEP 8 Count Weighing Mode 8 1 In this mode scale will weigh goods weight on scale calculate and display its counts after the piece weight of goods is obtained 8 2 To make counting function be available...

Page 12: ...3 After INP PCS being shown 000000 will be displayed use PRINT ACC UNIT key to input the quantity of samples and Press TARE key to confirm If the calculated piece weight is less than 0 5d the indicator will display PWt Er and go back to counting mode If successful the scale will go back to counting mode and you can start counting The piece weight will be saved after the power off and can be used n...

Page 13: ...percentage is corresponding to the weight you will input in following steps 10 5 1 2 When UNIT KG is shown use PRINT or ACC key to select the unit of input weight use TARE key to confirm and go to next Press ZERO key to exit and back to percent weighing mode 10 5 1 3 When last stored unit percentage weight data is shown use PRINT ACC UNIT key to input new unit percentage weight press SETUP key mor...

Page 14: ...gh number is 0 or is equal or less than low number the comparison will be disabled 11 5 After the limitations have been set and check weight function is be active one of annunciators HI OK LO will light up and the beeper will sound according to its setting in USER BEEP 12 BMI Working Mode 12 1 To use the BMI mode CONFIG FUNC BMI menu item should be set to YES 12 2 To enter BMI Working mode 8 2 1 L...

Page 15: ...tive Peak Number HOLD mode 2 Negative Peak Number HOLD mode 3 Toggle HOLD mode 4 Average HOLD mode 5 Auto HOLD mode The following are details of these HOLD modes 13 3 1 Positive Peak HOLD When USER HOLD HLD MOD is set to PS PEAK the hold mode is positive peak hold mode When scale first enters this working mode it will display the largest positive number that is from the time of zero pint set After...

Page 16: ... start averaging again or press HOLD key to exit 13 4 In Positive or Negative Peak HOLD mode the red HOLD for LED version or PEAK and HOLD for LCD version annunciator will be lighted in other HOLD mode green HOLD for LED version or HOLD for LCD version annunciator will be lighted When HOLD annunciator flash the displayed number is live When HOLD annunciator become steady the displayed number is fr...

Page 17: ...ght must be larger than USER OTHER NLD RNG piece or percentage can be accumulated by long pressing TOTAL key and indicator will display accumulation times first and then display total of number To avoid repeating accumulation for same load one load only can be accumulated once So before a new load put onto the scale the original load should be removed and let load on scale be smaller than USER OTH...

Page 18: ...o exit this mode 18 View Firmware Version 18 1 Press down SETUP until CONFIG is shown using PRINT or ACC key to select MISC VER item press TARE to display current Version 18 2 Firmware Version display Format is Vxx yy xx is hardware version yy is software version 18 3 Press SETUP key to return to last menu item press ON OFF key to prepare to exit this mode 19 Display Test 19 1 Press down SETUP mor...

Page 19: ... 23 Error codes and Troubleshooting 25 1 Meaning of Symbols 25 1 1 0 Zero is over the setting range 25 1 2 0 Zero point is below the setting range 25 1 3 Ad Signal to ADC is over max range 25 1 4 Ad Signal to ADC is below min range 25 1 5 Weight is over upper limitation or display data is over limitation 25 1 6 Weight is below lower limitation 25 1 7 EEP E1 CONFIG or CAL parameters are not correct...

Page 20: ...t of low point 25 1 25 SPL HI Sample load weight of high point 25 1 26 SPL PWT Sample goods weight to calculate piece weight 25 1 27 INP PCS input pieces number of weighted goods 25 1 28 UNIT KG Unit kg is selected 25 1 29 UNIT LB Unit lb is selected 25 1 30 PWT ER Piece weight is error it s too small 0 5d 25 1 31 SPL PCT Sample goods weight to calculate 25 1 32 INP PCT input percentage of weighte...

Page 21: ...sure Re set some parameters of CONFIG or UAER Weight reading below Under load limit Install platform on scale Perform zero calibration EEP E1 CONFIG or CAL parameters are not correctly set Re set items in CONFIG do calibration EEP E2 USER parameter is not correctly set Re set items in USER CAP ER Capacity parameters are not correct Set PRIM N PRIM d SECND n to correct number make sure capacity not...

Page 22: ...rd connections Make sure power cord is plugged into the power outlet Check power source Replace batteries Service required Cannot zero the display or will not zero when turned on Load on scale exceeds allowable limits Load on scale is not stable Load cell damage Remove load on scale Wait for load to become stable Service required Cannot display weight in desired weighing unit Unit not set to enabl...

Page 23: ... KILOTECH INC www kilotech com 22 25 Display Character ASCII LCD LED Show ASCII LCD LED Show ASCII LCD LED Show 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M Z ...

Page 24: ...w kilotech com 23 26 Packing List No CONTENT QTY 1 Indicator 1 2 User manual 1 3 Swivel bracket 1 4 AC Adapter 1 5 RS232 cable 1 6 USB interface 1 7 USB cable 1 9 1x CR2032 battery for RTC 1 10 AA Alkaline batteries 4 ...