background image

Summary of Contents for 9743 - 30 in. Electric Range

Page 1: ...TIAL FIRE HAZARD AND INCORRECT COUNTERTOP AND CABINET CUTS TO ELIMINATE THE RISK OF BU RNS OR FIRE BY REACHING OVER HEATED SU RFACE UNITS CABINET STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED IF CABINET STORAGE IS TO BE PROVIDED THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5 BEYOND THE BOTTOM OF THE CABINETS IMPORTANT SAFETY INSTRUCTI...

Page 2: ...n below to locate the bracket if template is not available Mark the floor or wall where left or right side of the range will be located Ifrearofrange is against the wall or no further than 1 1 4 from wall when installed you may use the wall or floor mount method If molding is installed Fig 4 and does not allow the bracket to fit flush against the wall remove molding or mount bracket to the floor F...

Page 3: ...s Cord Kit Ampere Rating 8 8 16 5 KW 7 9 12 5 KW 40 50 Amp 16 6 22 5 KW 2 6 18 5 KW 50Amp Fig 10 Diameter inches of Range connection Opening Permanent Cord Kit Wiring 1_3 8 in 1 1 8 in 1 3 8 in 1 3 8 in 4A POWER CORD CONNECTIONS 4 Wire Connection Instructions Refer to Fig 12 Before wiring the range review the suggested power source location drawing in Fig 3 If connecting to a 4 Wire electrical sys...

Page 4: ...installed nut connections which secure the range wiring to the terminal block Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed NOTE For 3 Wire Permanent Connections skip Steps 3 4 and continue with Step 5 3 4 Wire Permanent Connection ONLY Disconnect the ground strap Remove the factory installed ground screw plate to release the factory installe...