Summary of Contents for 79045119410

Page 1: ...netry is 30 76 2 cm 30 76 2 cm min for unprotected cabinet 24 61 cm min for protected surface C Cooktop Cutout Dimensions N Figure I 30 Model shown only PRODUCT D IMENSIONS MODEL A WIDTH BIDEPTH C HEIGHT D BOXWiDTH EBOX DEPTH 30 CeramicModel 30 77 8 21Vs 54 4 43 4 12 1 281 s 71 4 19 48 3 36 CeramicModel 36 93 211 2 54 6 4 12 1 331 2 85 1 18 47 6 CUT0UTDIMENSIONS EWlDTH G HIHEIGHT BEI OW 30 Ceramic...

Page 2: ...is figure refer to chart on front page except for J K L 12 30 5cm J Min From Edge of Cooktop to Nearest Combustible Wall Either Side of Unit For a drawer installation below the cooktop allow 8 20 4cm of clearance underneath the countertop The drawer must not interfere with the electrical installation of the cooktop or contain flammable materials To eliminate the risk of burns or fire resulting fro...

Page 3: ...d on both sides of the line a 40A time delay fuse or circuit breaker is recommended DO NOT fuse neutral NOTE Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA standard C22 1 Canadian Electrical Code Part 1 and local codes and ordinances An extension cord must not be used ...

Page 4: ...d use ground lead to ground unit in accordance with local codes connect neutral lead to branch circuit neutral conductor in usual manner see Figure 5 If your appliance is to be connected to a 3 wire grounded junction box US only where local code permit connecting the appliance grounding conductor to the neutral white see Figure 4 NOTE TO ELECTRICIAN The armored cable leads supplied with the applia...

Page 5: ...ers and screws can be found in a plastic bag packaged with the unit Install those spacers using the screws at the positions illustrated on figure 9 Spacer Install spacers Figure 9 4 Set the cooktop into the countertop cutout NOTE Do not use caulking compound cooktop should be removable for service when needed Granite countertop Installation Kit A Granite Countertop Installation kit 903061 9010 can...

Page 6: ... 1 4 x 4 10 2cm X 10 2cm opening to route armored cable from cooktop to junction box Approx 3 208 240Volt 7 5cm junction box for cooktop Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets Cabinet side filler height should allow for of approved cooktop models 36 Min 91 4cm Min Unit will overlap minimum edges by 1 2 5cm 41 2 11 5cm Max Use 3 4 1 gcm plywood installe...