User Manual

Technical Parameters

multisys D4-IGW-1

multimax D4-IGW-1

System 

I

 English

You can find the instructions for your KBR 

device at our download center.

https://www.kbr.de/de/dienstleistungen/

download-center

Summary of Contents for multimax D4-IGW-1

Page 1: ...720 1_EN User Manual Technical Parameters multisys D4 IGW 1 multimax D4 IGW 1 System I English You can find the instructions for your KBR device at our download center https www kbr de de dienstleistungen download center ...

Page 2: ... damage resulting from printing errors in or changes to this manual In addition KBR Kompensationsanlagenbau GmbH does not accept any liability for any loss or damage caused by defective devices or devices manipulated by the user Copyright 2020 by KBR Kompensationsanlagenbau GmbH Subject to change Table of Contents ...

Page 3: ...ion 9 3 1 Device assembly 9 3 2 Connection Diagram 10 3 3 Terminal Assignment 12 4 Network Communication 13 5 Configure Network Settings 14 5 1 Online 14 5 2 Offline 15 6 Hardware Reset 16 7 Establish SSH Connection 16 8 Technical Data 17 8 1 Technical Data for the multisys multimax D4 IGW 1 17 8 1 1 Control and display elements 17 8 1 2 Power supply 17 8 1 3 Hardware Outputs 17 8 1 4 Mechanical d...

Page 4: ...e technical details of the device and show how damage can be avoided through proper installation and commissioning 1 1 User Manual This user manual must be accessible to the user at all times e g in the switchgear cabi net Even if the device is resold to third parties the manual remains an inherent part of the device Although the utmost care has been taken in writing this user manual errors may st...

Page 5: ...means that minor injuries or damage may occur if the appropriate safety pre cautions are not taken NOTE Note is an important piece of information on the product its operation or the respective part of the user manual to which special reference is being made Disclaimer The contents of this user manual have been carefully reviewed in terms of the hardware and software described However deviations ca...

Page 6: ...may result in the destruction of the device When connecting the device adhere to the information given in the connection diagram see Connection diagram and that the connecting cables are not live When wiring always ensure that all cables used are neither damaged nor faulty and observe correct polarity Proper and safe operation of the product requires correct transport storage installation and asse...

Page 7: ...evice characteristics only applies if the device is operated in accordance with its intended use 1 5 Scope of Delivery Included in the scope of delivery multisys D4 IGW 1 or multimax D4 IGW 1 User manual 1 6 Disposal Please dispose of defective out of date or no longer used devices properly If you wish we can dispose of the device for you 1 7 Overvoltage and Lightning Protection To protect your pu...

Page 8: ...ge of Functions multimax D4 IGW 1 The module is already configured as a web server You can connect to the URL http IP or host name on the nameplate with a browser You will be directed to the login page Range of Functions There are three user profiles defined Profile Default Password Live Data Historical Data Standard Configurations Expert Configurations Viewer viewer x x Standard user x x x Expert...

Page 9: ...ION The device control voltage must be secured with a back up fuse on site The electrical installation of the building must have a disconnecter or circuit breaker for the power supply voltage The disconnecter must be close to the device and be easily accessible to the user It must be marked as an isolating switch for this device The isolating switch must be UL IEC approved During installation plea...

Page 10: ...V1 00 25845_EDEBDA0291 4720 1_EN 10 Installation 3 2 Connection Diagram Figure 1 Connection diagram Figure 2 Connections on top ...

Page 11: ...V1 00 25845_EDEBDA0291 4720 1_EN 11 Installation Figure 3 Connections on bottom Figure 4 Front view ...

Page 12: ...hnical data please refer to the nameplate Terminals 90 ground 91 A and 92 B Serial Port 1 RS485 Communication Port e g KBR eBus Module OUT A Serial Port 1 For communication with the KBR expansion modules Maximum Output Power 2W Ethernet Network Connection for Ethernet TCP USB Universal Serial Bus USB 2 0 HDMI HDMI Display Connection 3 3 Terminal Assignment ...

Page 13: ... the system can also be made by giving the com puter name host name regardless of the assigned IP address This can be found on a sticker on the side of the housing Successful communication always requires that the D4 IGW 1 and its communication partner are in the same network subset If the system receives a DHCP address this is typically the case However if no DHCP server is available the communic...

Page 14: ...al session with the following command sudo nano etc dhcpcd conf The section to be edited is at the end of file Static address assignment for the following entries remove the annotation and modify as desired static ip_address 192 168 180 123 24 IP Adresse Subnetzmaske static routers 192 168 180 1 Gateway static domain_name_servers 192 168 180 2 DNS server Dynamic address assignment DHCP comment out...

Page 15: ...section to be edited is at the end of file Static address assignment for the following entries remove the annotation and modify as desired static ip_address 192 168 180 123 24 IP Adresse Subnetzmaske static routers 192 168 180 1 Gateway static domain_name_servers 192 168 180 2 DNS server Dynamic address assignment DHCP comment out the following entries static ip_address 192 168 180 123 24 IP Adres...

Page 16: ...appropriate tool for 5 seconds to do so Then the settings will be reset an LED on the front of the housing will blink to confirm that the process was successful 7 Establish SSH Connection Using a standard SSH client a secure connection can be established to the D4 IGW 4 for example using Kitty or Putty under Windows The host name or even the IP address given can be used as the target standard SSH ...

Page 17: ...ial interface RS 485 Protocol and speed depend on software configu ration Module bus interface Serial interface RS 485 RJ12 for ready made KBR system cable 6 pin modular cable unshielded max length 30 m if placed suitably Maximum output power 2W USB inter face Serial interface USB 2 0 Port Display interface HDMI interface Monitor port 8 1 4 Mechanical data Top hat rail device Housing dimensions 90...

Page 18: ...ty 5 95 non condensing Storage temperature K55 25 C 70 C Operating height 0 2 000 m above sea level Electrical safety Standards DIN EN 61010 1 2011 07 Protection class I Overvoltage category CAT III Relay CAT II Rated surge voltage 4kV Protection type Standards IP20 in accordance with DIN EN 60529 2014 09 EMC Standards DIN EN 61000 6 2 2006 03 amend ment 1 2011 03 DIN EN 61000 6 3 2011 09 amend me...

Page 19: ...Notes V1 00 25845_EDEBDA0291 4720 1_EN 19 ...

Page 20: ...25845_EDEBDA0291 4720 1_EN Am Kiefernschlag 7 D 91126 Schwabach Germany T 49 0 9122 6373 0 F 49 0 9122 6373 83 E info kbr de www kbr de KBR Kompensationsanlagenbau GmbH ...