background image

User Manual 

v.2.1

JEFC050L10B-230 

AIR COMPRESSOR

230V~50Hz • 10Bar • 2HP • DIRECT DRIVE

 

50L

Summary of Contents for JEFC050L10B-230

Page 1: ...User Manual v 2 1 JEFC050L10B 230 AIR COMPRESSOR 230V 50Hz 10Bar 2HP DIRECT DRIVE 50L ...

Page 2: ...www jeffersontools com 2 USER MANUAL v2 1 JEFC050L10B 230 50L AIR COMPRESSOR 230V 50Hz 2HP 10Bar Direct Drive ...

Page 3: ...ry information to ensure its correct and safe use We recommend that this manual is read before any operation or before performing any kind of adjustment to the product and prior to any maintenance tasks By following all the general safety instructions contained in this manual you will help to ensure operator safety and extend the potential lifespan of the equipment All photographs and drawings in ...

Page 4: ...livery 5 0cfm 132 L min Maximum Pressure 10bar 145psi Wheel Diameter 150mm Lubrication Semi Synthetic SAE30 Optional 15W 40 300 cc Weight NW 36 8kg GW 39 8kg Box Dimensions 795 x 365 x 710mm UNPACKING ASSEMBLY Remove compressor from the carton Wear protective gloves and cut the outer strapping with side cutters Remove the staples with long nose pliers and open the top flaps With assistance careful...

Page 5: ...the red dot indicates the low mark Important Always ensure that the oil level is correct before operating the compressor Ensure working environment is suitable for use This compressor must be used on a flat level surface The maximum safe operating angle in any direction is 10 degrees see Fig 5 Do not operate the compressor on inclines in excess of 10 degrees Serious damage to pump components may r...

Page 6: ...ate that all portable equipment must be inspected regularly and tested to ensure that it is safe for use Portable equipment means any electrical item that can be moved and this is often referred to as Portable Appliance Testing PAT PAT testing should be carried out regularly on this equipment by trained authorised personnel as required by the legislation The Health and Safety at Work Act 1974 stat...

Page 7: ... motor air vent must be kept clean so that air can freely flow at all times Check for dust build up frequently and clean as required If the equipment appears to be operating unusually making strange noises or otherwise appears defective stop using it immediately and arrange for repairs by a authorized service centre Solvents such as petrol thinner benzine carbon tetrachloride and alcohol may damag...

Page 8: ... paint in a confined area with the air compressor Operate the air compressor in well ventilated areas free from obstructions Equip areas with fire extinguishers suitable for electrical fires Do not leave nylon material shirts or jumpers on the compressor Store paint thinners and other flammable liquids in approved containers in a secure location away from the work area Minimum clearance 0 5m Maxim...

Page 9: ...the pressure gauge The compressor will now operate automatically The pressure switch stops the motor when the maximum tank pressure is reached and restarts it when the pressure falls below the minimum threshold approx 2 bar 29psi less than the maximum pressure Stopping The Compressor Stop the compressor by moving the main switch to the OFF position The compressed air inside the compressor head wil...

Page 10: ...thorised service agent There is a leak from the base of the pressure switch when the compressor is stopped The Non return valve from the tank is leaking Disassemble and clean if necessary replace valve insert Contact your authorised service agent The compressor is noisy with metallic clangs knocks Bearing or piston problem Low oil level Stop the compressor and contact a specialized service technic...

Page 11: ...nd disconnected from the power source Allow the compressor pump and other parts to cool off if changing oil after use Ensure compressor is on a flat and level surface Remove fill cap plug and place collection container underneath the oil drain cap Remove the oil drain cap and let the oil drain out Replace the oil cap and be sure to tighten this nut securely you can use some PTFE tape on the thread...

Page 12: ...www jeffersontools com 12 USER MANUAL v2 1 JEFC050L10B 230 50L AIR COMPRESSOR 230V 50Hz 2HP 10Bar Direct Drive PARTS DIAGRAM MAIN ASSEMBLY ...

Page 13: ...asher 7 2 Het Screw 8 1 Mini ball balve 9 2 Washer 10 2 Wheel 11 2 Wheel spacer 12 2 Washer 13 2 Washer spring 14 2 Screw 15 1 Air tank 50L CE 16 2 Screw 17 6 Hex screw 18 4 Plate washer 19 1 Check valce cap 20 2 Sleeve 21 1 Al tube 22 1 Bushing Rilsan tube 23 1 Sleeve 24 1 Sleeve lock nut 25 1 Rilsan tube 26 1 Pressure gauge 27 1 Pressure switch 28 1 Safety valve 29 1 Nipple 30 1 Pressure regulat...

Page 14: ...www jeffersontools com 14 USER MANUAL v2 1 JEFC050L10B 230 50L AIR COMPRESSOR 230V 50Hz 2HP 10Bar Direct Drive PARTS DIAGRAM PUMP ...

Page 15: ... 20 1 Gasket Crankcase 21 1 Cover Crankcase 22_1 1 O RING 22_2 1 Oil Sight Glass 23_1 1 O Ring 23_2 1 AIR Breather 24 1 Capacitance 25 1 Overload Protector 26 1 Piston 27 2 Con Rod 28 2 Circlip 29 1 Piston Pin 30 1 Piston Part Number Quantity Description 31 1 Piston Ring Kit 31_1 1 Oil Ring 31_2 1 Scraping Ring 31_3 1 Compression Ring 32 1 Cylinder Gasket 33 2 Stud Bolt 34 2 Hex Nut 35 1 Cylinder ...

Page 16: ...in the European Union If you wish to discard electrical and electronic equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal We hereby d...

Page 17: ... Cesta 56 821 01 Bratislava Country Slovakia 1354 2011 65 EU as amended RoHS Directive Intertek Testing Services Shanghai Block B Jinling Business Square No 801 YiS han Road Shanghai China 200233 0012 Equipment Category Air Compressor Item 8 Product Name Model 50L Air Compressor JEFC050L10B 230 50L 230V 2HP 10Bar Direct Drive Air Compressor Measured Sound Power Level Guaranteed Sound Power Level 9...

Page 18: ...d as it eliminates the need to provide proof of purchase should a warranty claim be necessary Warranty Repair Should Jefferson confirm the existence of any defect covered by this warranty the defect will be corrected by repair or replacement at an authorized Jefferson dealer or repair centre Packaging Freight Costs The customer is responsible for the packaging of the equipment and making it ready ...

Page 19: ...fective and in need of repair and any repairs needed are covered by the warranty policy In order to qualify for warranty cover all equipment presented must have been used serviced and maintained as instructed in the user manual Where repair is not covered by the warranty a quotation for repair labour costs and return delivery will be sent to the customer normally within 7 working days Note If the ...

Page 20: ...ness Park Chester United Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating instructions outlined in this manual to reduce the risk of fire electric shock or personal injury www jeffersontools com www jeffersontools com ...

Reviews: