The JA-154J MS II Bi-directional four-button key fob 

JA-154J MS II 

1 / 2 

MMJ25100 

The JA-154J MS II  is  designed  to 

remotely control a security system, various 
appliances (utilizing  programmable  PG 
outputs) or to trigger panic alarms. The key 
fob  can also be enrolled to multipurpose 
relays such as the AC-16x series for direct 
relay control  according to the pre-set 
mode. The remote is equipped with optical 
and acoustic indication. It checks its battery 
status and indicates when the battery is 
nearly discharged.  The remote commu-
nicates via the Jablotron wireless protocol 
and is powered by a single power cell. The 
remote takes up a single position in the system. 

Figure:

 1 – LED indication A, B, C, D – buttons,

 see their functions 

according to table 1.

 

Enrolling the remote control to a control panel 

There must be a JA-11xR radio module installed in the control panel for 

the ability to work with a control panel. It occupies one position in the system. 

The remote can be enrolled to an arbitrary number of 

JABLOTRON 100+  systems. One pair of buttons can control several 
sections at the same time (common control) and it can show the current 
status of the section or PG output. 
1.

The control panel has to be in service mode.

2.

Basic procedure:
a.

Go to  the 

F-Link

  software, select the  required position in the

Devices

 tab and launch 

enrollment mode

.

b.  For transmission of an enrollment signal press and hold buttons

(A+B) simultaneously for at least 3 s (within this time the yellow
LED flashes rapidly).

c.  After 3 s the enrollment signal is sent and confirmed by one long

yellow LED flash. Release both buttons and close enrollment
mode.

To set the keyfob to comply with security 
grade 2 use F-Link SW, Parameters tab 
and the option “Perform EN50131-1”. 
(See the JA-10xK control panel 
installation manual)

 

Notes: 

Enrolling the remote control to the system is possible by entering
the production code via F-Link software. The production code is on
the sticker with a bar code glued onto the battery holder inside the
remote. All digits in the production code are required
(example: 1400-00-0000-0001)

If you want to remove the remote control from the system (for
instance when someone has lost it), erase it from the particular
address of the control panel.

Setting the properties 

Perform settings using 

F-Link

  software – 

Devices

  tab.  Click on the 

JA-154J´s 

Internal settings

.  Then a window appears automatically 

where you can set the following parameters: 

Functions of the buttons:

  set a particular function for the pair of 

buttons A-B or C-D  (typically setting / unsetting,  OFF / ON switching of 
some appliance, etc.) or a function for each single button A, B, C, D 
(gate opening, garage door opening, etc.) and also for a double press of 
the remote. See the following table 1. 

 

Reaction for single button 

/ / /

 (A/B/C/D) 

Reaction for pressing 

simultaneously 

+ / +

  (A+B/C+D)

 

None (button not used)

 

Change PG status

 

Copy PG

 

Silent panic *)

 

Audible panic*)

 

Health troubles

 

Report A, B, C, D

 

None (button not used)

 

Change PG status

 

Copy PG *)

 

Silent panic **)

 

Audible panic**)

 

Health troubles

 

Report A, B, C, D

 

Read status ***)

Reaction for pair of buttons (segment function) 

-

 

/

 

-

(A-B/C-D)

 

Unset / Set

 

Unset / Partially set

 

Unset / Partially set / Set

 

Unset / Set with confirmation 

 

Unset / Partially set with confirmation 

 

Unset / Partially set / Set with confirmation 

 

PG OFF / ON

Table 1. Button function options overview 

For each function selected for a remote control button it is necessary 

to select the appropriate PG or sections to be controlled, or from which 
reports should be reported (panic, etc.). For the common control  of 
multiple sections  it  is not recommended to operate a common section, 
but to select the desired section in the remote control internal settings. 

Notes: 

*)

   Once a button (with the “Copy PG” function enabled) is pressed and 

  held, the activation signal is transmitted every second. The function 
  can be utilized to extend the duration of a PG output (said PG shall 
  must the “copy PG” function enabled). The maximal length of 
  continuous transmission is 1 minute. 

**)   The 

„Copy PG“ 

reaction to a  double press can  be used for a  1 s 

impulse only for the  selected PG – double  button  pressing  cannot 
send 1s activation signal repeatedly unlike single buttons. 

***)  The  reactions of the buttons  which are not supported when the 

system is configured comply with security grade 2. 

****)

If there is a pre-set function for the pair of buttons A+B (typically 
Unset / Set section or PG OFF / ON), then that option also triggers 
the  option 

„Read status“

. If this  option is enabled the  remote 

reacts to a  double press by showing the current status of the 
section or PG. 

For all functions related to setting the sections, the  control panel 

follows the option 

Ways of setting

 selected in the Parameters tab. 

a.

For 

„with confirmation“ 

types of setting (see table 1),  for 

„set

with warning“ 

options and  for 

„set with confirmation“ 

pressing

the buttons in an 8 s period

 

can be repeated and the command

is performed..

b.

The option „

Do  not set with active zone“, 

doesn´t allow the

system to be set using a remote control (keyfob) when any
zone with an 

Instant

  reaction is active. To set the system all

zones have to be in standby.

Take over a user´s access privileges:

 Taking over a user´s access 

privileges for the sections and time limited access according to the 
specific user, it respects individual  access to the controlled section and 
also limited access to a section if pre-set. Factory settings: disabled. 

Take over a user´s identity:

  The selected user will be visible as 

a source in the event log. Factory settings: disabled. 

Delayed panic:

  Valid for  reactions such as Silent panic and Audible 

panic. The delay can be set from 5 to 240 s. Cancelling the panic alarm 
during  a  running delay can be performed by repeated pressing of the 
specific button. 

Operation with a multipurpose relay (MPR) 

The remote control can also be enrolled to a multipurpose relay of the 

AC-16x series, to control a relay according to the chosen mode. Each 
button should be enrolled to the MPR with a different mode. Even one 
remote can be enrolled to multiple MPRs for example with a different 
function. When you enroll a keyfob to the control panel and also to an 
MPR within its RF range, don´t select the same buttons.  To enroll 
a keyfob to an MPR, follow the installation manual of the MPR.  

Locking the keyfob 

The remote control buttons can be locked (blocked) against 

accidental pressing. Locking is disabled by default, pressing any button 
triggers its function immediately.  

If the buttons are locked, a control panel command is sent when 

a button is pressed 2x quickly (2x per 1 s) it is also valid for the panic 
function. 

Caution:  When a reaction for pressing buttons (A+B) or 

(C+D)  simultaneously is set  (for example a  panic alarm or 
garage door control), it is necessary to mind that the action is 
performed first. 

The 

lock can be activated 

by simultaneously  pressing and holding 

the pair of buttons (A+B) or (C+D) until the yellow LED (1) starts 
flashing, usually in 3 s. When  the  yellow  LED (1) is flashing release 
button B and press it again. Activation of the lock function is performed 
and confirmed by double flashes of the yellow LED and a double beep. 
After this confirmation release all buttons. 

The 

lock is deactivated 

by repeating the procedure above. 

Deactivation of locking is confirmed by one flash of the yellow LED and 
one beep. 

The control panel is able to run a maximum 
of 5 simultaneous timers (delayed panic 
alarms). 