background image

PAGE 

!

 OF 

!

1

2

Operator Usage Guide

  

                            

   ED2E-

Elite 

SkidWeigh 

(Compact Series)

    

ED2E SkidWeigh Series

 

  • 

Turn on ignition switch 

  • 

With LED display will show software version for the moment and mode will indicate 
number 8 which is the starting point to initiate load weight cycle                                                                                                    

(Loaded forks must be lowered to ground, no pressure in lift hydraulic circuit for the system to show Mode 8)

 

   

                                                                                                                                   

Insert the forks into the pallet or product to be weighed 

  • 

Lower the loaded forks to the ground. 

  • 

With LED display showing number 8 in Mode, lift load just above the ground 

  • 

Do not manipulate the tilt, side shifter or move vehicle during the weighing cycle 

  • 

Lift the load approx. 2” off the ground using the hydraulic lift lever same as during 
normal usage. Do not use lift lever by lifting load “slowly”. 

          

   • 

Within few seconds load weight will be indicated on LED display.                            

Note:

 During the normal vehicle usage the LED display might show “0” or some other load 

weight which is due to the hydraulic “spikes”. To initiate a load weighing cycle you must lower 

loaded forks to the ground and LED must show number 8 in Mode window.

 

LED Display

Bluetooth LED 

LED Light 

Busy (orange) 
Ready (green) 

Load Weight Add Button

Accumulative Load 

Weight Total and 

Print Button

Reviews: