background image

SCALA ICE MACHINE MAINTENANCE 

 

 

1.  AIR CONDENSER CLEANING: 

 

1.

 

Disconnect the unit from the electricity.

 

2.

 

Clean condenser using a vacuum cleaner, soft brush or low-pressure air. Clean from top 
to bottom, not side to side. Be careful not to bend the condenser fins.

 

3.

 

Connect the unit to the electricity.

 

 

2.  WATER FILTER REPLACE 

 

1.

 

Disconnect the unit from the electricity.

 

2.

 

Closet the inlet water faucet.

 

3.

 

Close the faucet before the filter.

 

4.

 

Remove the old cartridge and replace it with a new one.

 

5.

 

Open all the closed faucets.

 

6.

 

Connect the unit to the electricity.

 

 

3.  WATER CIRCUIT CLEANING: 

 

1.

 

Disconnect the unit from the electricity.

 

2.

 

Closet the inlet water faucet.

 

3.

 

Open the drainage faucet (only on machines less than the 5 tons) to drain the water tank 
completely. Use a container to collect the water.

 

4.

 

Close the drainage faucet.

 

5.

 

We  recommend  using  the  cleaning  product  Calklin.  Prepare  a  solution  with 

50% 

phosphoric  acid 

and  distilled  water. 

Do  not  use  hydrochloric  acid

.  The  mixture  is 

more  effective  if  the  water  is  between  35ºC  and  40ºC.  Pour  the  mix  slowly  in  the 
water tank (previously remove the cover).

 

6.

 

Before connecting the unit, the cold production must be disable. To do so, access the 
electric box from the evaporator and disconnect the cable connected to the #6 terminal.

 

7.

 

Open the inlet water faucet and connect the unit. Let the solution flow for 20 minutes.

 

8.

 

After that, open the drainage faucet, or empty the water bin. By doing so the solution 
will be diluting, with the water pump on and the inlet water faucet open.

 

9.

 

After 10 minutes, stop the unit and close the inlet water faucet. Wait until the whole 
unit is completely drained.

 

10.

 

Once the unit is drained, close the drainage faucet and open the inlet water faucet.

 

11.

 

Before connection the unit, please reconnect the cold production. To do so access the 
electric box again and connect the cable to the terminal #6.

 

12.

 

Connect the unit to the electricity. Produce ice for 5 minutes.

 

 

CAUTION: Discard the ice produced during this time. 

 

13. 

After this time the unit can be used normally.

 