background image

6051344      

Rev. 1.0

Page 1 of 17

212iLM Mullion  (

ILLUMINATED WEATHER RESISTANT

)  Keypad

Stand Alone Keypad-Installation Manual

Features:

v

 

120 User Capability

v

 

Illuminated Hardened Keys

v

 

Programmable 00-99 Second Relay Activation Time

v

 

Remote Trigger Input (REX)

v

 

Bell output (timed or continuous)

v

 

Designed for Heavy Traffic Application (greater than 1 million cycles)

v

 

Surface Mount

v

 

Indoor / outdoor Applications

v

 

Fully encapsulated

Installation:

q

 

Section 1:

  Unpacking and checking the packing list

q

 

Section 2:

  Mounting the 212iLM Mullion

q

 

Section 3:

  Wiring the 212iLM Mullion

q

 

Section 4:

  Power Up and System Defaults

q

 

Section 5:

  Programming the 212iLM Mullion

q

 

Section 6:

  Trouble Shooting

International Electronics, Inc.
427 Turnpike Street
Canton, Massachusetts 02021

Summary of Contents for 212iLM Mullion

Page 1: ...ontinuous v Designed for Heavy Traffic Application greater than 1 million cycles v Surface Mount v Indoor outdoor Applications v Fully encapsulated Installation q Section 1 Unpacking and checking the...

Page 2: ...ng for the wire splices a ruler or measuring tape silicone to seal any holes and possibly some electrical tape to hold the wires together or the template in place q Section 2 Mounting the 212iLM Mulli...

Page 3: ...lue common wire from the 212iLM Mullion harness to the Red wire on the 212iLM Mullion harness and to positive voltage coming from the power supply Step 2 Connect the White Yellow wire normally closed...

Page 4: ...ss of the 212iLM Mullion Step 1 Splice together the Blue common Relay wire from the 212iLM Mullion harness to the Red wire on the 212iLM Mullion harness and to positive voltage coming from the power s...

Page 5: ...common wire from the 212iLM harness to the Positive voltage on the lock power supply Step 5 Connect the Negative voltage coming from the lock power supply to the Negative connection on the Electric S...

Page 6: ...the external relay Step 1 Connect the White with Black trace wire on the 212iLM Mullion harness to the common connection on the REX device Step 2 Splice a wire to the Black negative wire on the 212iLM...

Page 7: ...ing mode has been exited The red LED should now be on Perform the Self Test by pressing 7890 123456 The LED s will cycle from Green to Yellow to Red and then the sounder will beep three times Press 12...

Page 8: ...n comes with the factory programmed Master code of 1234 This may be changed to any code that has 1 to 6 digits in length The 212iLM Mullion also comes set from the factory with a 5 second relay activa...

Page 9: ...is entered to close the relay Enter Programming Mode 99 Master code Next enter the relay time of 00 followed by the key Next enter the user location 2 3 4 etc followed by the key Now enter the new cod...

Page 10: ...ess Command number 30 followed by the key Next press 1 for the visual feed back option followed by the key Next press 0 to Disable or 1 to Enable the visual option followed by the key Next press the k...

Page 11: ...ng Mode 99 Master code Next press Command number 32 followed by the key Next press 0 for the doorbell option followed by the key Next press 0 for continuous Or enter a time of 1 trough 99 for timed ou...

Page 12: ...lts When this command has been done successfully the 212iLM Master code will return to the default of 1234 and the main relay will activate for 05 seconds The 212iLM Mullion has to be in programming m...

Page 13: ...nd reprogram User locations are explained in Section 5 Add a user to latch the main relay Press 00 user location new code repeatcode Add a user with a different output time on the main relay Press rel...

Page 14: ...d of 35 Volts you must reduce the voltage to under 29 Volts Situation 3 The Master code is not allowing access to the programming mode Reason There are a few reasons that this situation could occur Th...

Page 15: ...sent to IEI s facility freight and insurance charges prepaid after obtaining IEI s Return Merchandise Authorization IEI WILL not be liable to the purchaser or any one else for incidental or consequen...

Page 16: ...6051344 Rev 1 0 Page 16 of 17 NOTES IEI suggests that you make a record of your installation for future reference...

Page 17: ...6 1 4 Diameter of the mounting holes is 11 64 Diameter of the wiring holes is 7 8 This product is designed as a surface mountable product The access hole for the wires is determined by the amount of...

Reviews: