Summary of Contents for INH-GB-01

Page 1: ... HEALTH NON CONTACT INFRARED THERMOMETER INH GB 01 USER MANUAL innovuhealth co ...

Page 2: ...ccuracy with age so we advise replacing it Product Intended Use The infrared thermometer is intended for the measurement and monitoring of human body temperate for people of all ages Attentions Notes Before use please read the instructions and make sure the batteries provided have been installed Ensure this device does not have contact with liquid or extreme high low temperature Avoid this device ...

Page 3: ...unction default alarm value is 38 0 C and above Capacity to store 20 readings in memory Optional unit of temperature C or F Automatic shut down and power saving Measurement Method Icon Definition Measuring mode 1 Measuring mode 2 Temperature unit Object temperature mode Battery capacity Icon Icon Definition Forehead and object temperature measurement Ear temperature measurement Celsius or Fahrenhe...

Page 4: ...e MEM button and hold for 6 seconds and the screen will then display C If you want to change it to F press the MEM button once more and hold for 3 seconds C Voice switch setting Whenpoweredon holdtheMEMbuttonfor4seconds itwillbeeponceandthencloseoropenup Note thesoundkeycanbeseton offdependingontheenvironment e g itcanbeoffwhensilenceisappreciated D Shutdownkey Whenpoweredon holdtheMEMbuttonfor8se...

Page 5: ...The thermometer can then begin taking object measurements by pointing the device at the object at 3 5mm away Press and hold the MEM button When you hear a beep the temperature will then display on the screen The device only needs routine cleaning and period or times can be decided according to user s need The surface cleaning use a clean soft cloth or cotton swab stick moistened with a little medi...

Page 6: ...ains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of this device requires continued power without interruption we recommend this device is powered from an uninterruptible power supply or a battery Power frequency magnetic fields should be at levels characteristic of a typi...

Page 7: ...nt should be used no closer to any part of the device than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 P NOTE 1 At 90MHz and 800MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection fr...

Reviews: