background image

Connection

examples

*6

Performance_Level: e to

DIN EN ISO 13849-1

SIL 3 to DIN EN 61508

Category 4 to EN954-1

We reserve the right to make alterations without prior notice

ifm electronic.gmbh

Date: 22.03.07

page 1 of 15

Connection examples

for wiring the safety relay

G1501S

Summary of Contents for G1501S

Page 1: ...vel e to DIN EN ISO 13849 1 SIL 3 to DIN EN 61508 Category 4 to EN954 1 We reserve the right to make alterations without prior notice ifm electronic gmbh Date 22 03 07 page 1 of 15 Connection examples...

Page 2: ...SSO RI WKH QRQ FRQWDFW VDIHW GHYLFH FXUUHQW FRQVXPSWLRQ P YLD WKH 6 LWK PRQLWRUHG VWDUW DQG VXSSO RI WKH QRQ FRQWDFW VDIHW GHYLFH FXUUHQW FRQVXPSWLRQ P YLD WKH 6 LWK DXWRPDWLF VWDUW DQG H WHUQDO VXSSO...

Page 3: ...be connected The outputs are activated after pressing and releasing the start button with closed input circuits e stop button not pressed By pressing the e stop button the outputs are de energised th...

Page 4: ...safety switch button pressed By pressing one or both buttons of the safety switch opening contacts the outputs are de energised the contacts 13 14 and 23 24 are opened the signal output Y7 is deactiv...

Page 5: ...ch By opening one or both contacts of the safety switch the outputs are de energised the contacts 13 14 and 23 24 are opened the signal output Y7 is deactivated A new cycle can only be started after o...

Page 6: ...oth or only one OSSD of the safety device switch off the outputs of the G1501S are de energised The contacts 13 14 and 23 24 are opened the signal output Y7 is deactivated The safety device is supplie...

Page 7: ...outputs of the G1501S are de energised The contacts 13 14 and 23 24 are opened the signal output Y7 is deactivated The safety device is supplied via the unit G1501S L of the device to Y4 and L of the...

Page 8: ...rior notice ifm electronic gmbh Date 22 03 07 page 8 of 15 3 3 With automatic start and external supply of the non contact safety device current consumption 50 mA The safety device is externally suppl...

Page 9: ...r notice ifm electronic gmbh Date 22 03 07 page 9 of 15 3 4 With monitored start and external supply of the non contact safety device current consumption 50 mA The safety device is supplied externally...

Page 10: ...gures the unit for the automatic start If a feedback contact is to be monitored it must be connected between Y1 Y2 instead of the link If the correct clock signal is read by the G1501S the outputs of...

Page 11: ...re activated at the terminals Y1 and Y2 after pressing and releasing the start button If feedback contacts are to be monitored they must be connected to Y1 Y6 otherwise a link must be connected If a d...

Page 12: ...thout prior notice ifm electronic gmbh Date 22 03 07 page 12 of 15 4 3 With automatic start and external supply of the non contact safety device The clocked fail safe sensor is supplied externally L o...

Page 13: ...ut prior notice ifm electronic gmbh Date 22 03 07 page 13 of 15 4 4 With monitored start and external supply of the non contact safety device The clocked fail safe sensor is supplied externally L of t...

Page 14: ...d A new cycle can only be started after enabling releasing both S1 and S2 buttons The outputs are not enabled if the time between actuating both switches is longer than 0 5 s The outputs 13 14 and 23...

Page 15: ...ctivated If one or both buttons are released the outputs 13 14 and 23 24 open immediately Y7 is deactivated A new cycle can only be started after enabling releasing both buttons S1 and S2 The outputs...