Summary of Contents for BROCADE 4 GB FC HBAS

Page 1: ...Brocade 4 Gb SAN Switch Module for IBM Eserver BladeCenter Installation Guide ...

Page 2: ......

Page 3: ...Brocade 4 Gb SAN Switch Module for IBM Eserver BladeCenter Installation Guide ...

Page 4: ...n Appendix B Warranty on page 43 and Appendix C Notices on page 67 First Edition October 2005 Copyright International Business Machines Corporation 2005 All rights reserved US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Page 5: ...tch module status LEDs 21 Fibre Channel port status LEDs 22 Chapter 4 Configuring the switch module through the Telnet interface 25 Connecting to the switch module 26 Establishing a Telnet session through the management module 26 Establishing a Telnet session in a command line window 27 Chapter 5 Configuring the switch module through the Advanced Web Tools interface 29 Connecting to the switch mod...

Page 6: ...y return program 71 Electronic emission notices 72 Federal Communications Commission FCC statement 72 Industry Canada Class A emission compliance statement 72 Australia and New Zealand Class A statement 72 United Kingdom telecommunications safety requirement 72 European Union EMC Directive conformance statement 73 Taiwanese Class A warning statement 73 Chinese Class A warning statement 73 Japanese...

Page 7: ...rskrifterne før du installerer dette produkt Lees voordat u dit product installeert eerst de veiligheidsvoorschriften Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza ...

Page 8: ...to cross reference an English caution or danger statement with translated versions of the caution or danger statement in the IBM Safety Information book For example if a caution statement begins with a number 1 translations for that caution statement appear in the IBM Safety Information book under statement 1 Be sure to read all caution and danger statements in this documentation before performing...

Page 9: ...equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the installation and configuration procedures v Connect and disconnect cables as described in the following table when installing moving or opening covers on this product or attached...

Page 10: ...ntrols or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Class 3A or Class 3B laser diode Note the following Laser radiation when open Do not stare into the beam do not view directly with optical instruments and avoid direct exposure to the beam Class 1 Laser Product Laser Klasse...

Page 11: ...a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling ADVERTENCIA El contacto con el cable de este producto o con cables de accesorios que se venden junto con este producto pueden exponerle al plomo un elemento químico que en el estado de California de los Estados Unidos está considerado como un causante de cancer y de de...

Page 12: ...x Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 13: ... BladeCenter unit 3 The illustrations in this document might differ slightly from your hardware 4 The sample screens that appear in this document might differ slightly from the screens that are displayed by your system Screen content varies according to the type of BladeCenter unit that you are using and the firmware versions and options that are installed 5 When you are using the Brocade switch m...

Page 14: ...l MAC address _____________________________________________ Worldwide name WWN _____________________________________________ The switch module has the following labels v Product name label which is on the right side of the switch module v Serial number label which contains the product part number and serial number and is on the left side of the switch module v Safety certification label which is o...

Page 15: ...ement information base MIB support v External ports that can be configured as F_ports fabric ports FL_ports fabric loop ports or E_ports expansion ports v Internal ports that are configured as F_ports at 2 Gbps or 4 Gbps v Frame filtering technology that enables advanced zoning and monitoring capabilities v Optional small form factor pluggable SFP modules The following software features come with ...

Page 16: ...ess External port type F_port FL_port E_port Self discovery based on switch type U_port an optional port type Internal port type 2 Gbps or 4 Gbps Port characteristics External ports automatically detected and self configuring Number of Fibre Channel ports 6 external ports and 14 internal ports Scalability 239 switches maximum depending on your configuration Fibre Channel switch module standards an...

Page 17: ...s traffic information and Fibre Channel failure data through SNMP and the Ethernet interface Dimensions v Width 112 mm 4 41 in v Height 29 mm 1 14 in v Depth 260 3 mm 10 25 in v Weight Approximately 0 91 kg 2 lb Environmental v Temperature and altitude Operating 10 C to 52 C 50 F to 125 6 F at an altitude of 0 to 914 m 0 to 3000 ft 10 C to 49 C 50 F to 120 2 F at an altitude of 0 to 3000 m 0 to 10...

Page 18: ...d v Emissions standards FCC part 15B Class A USA VCCI Class A ITE Japan ICES 003 issue 3 Canada A4EN55022 level A EC Voltage fluctuations EN 61000 3 3 Harmonics EN 61000 3 2 Immunity EN 55024 1998 v Marking FCC part 15 UL United States cUL Canada TUV VCCI CE 6 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 19: ...bric OS Administrator s Guide v Web Tools Administrator s Guide v Safety Information The following related documentation is available at http www ibm com support v BladeCenter Hardware Maintenance Manual and Troubleshooting Guide v BladeCenter unit Management Module Command Line Interface Reference Guide v Management Module User s Guide for the BladeCenter unit v Installation and User s Guide for ...

Page 20: ...hanges are made periodically to the IBM Web site The actual procedure might vary from what is described in this document Inventory checklist Make sure that the shipping carton contains the following items v One Fibre Channel switch module Brocade 20 port 4 Gb SAN Switch Module for IBM Eserver BladeCenter or Brocade 10 port 4 Gb SAN Switch Module for IBM Eserver BladeCenter v The Brocade 4 Gb SAN S...

Page 21: ...A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation Major components of the switch module The following illustration shows the major components of the switch module Note The illustrations in this document might differ slightly from your hardware and your switch module might have labels that are not shown in the followi...

Page 22: ...cation between the blade server and the switch module For information about the types of compatible Fibre Channel expansion cards for the blade servers contact your IBM marketing representative or authorized reseller See the expansion card documentation for details about expansion card installation configuration and use 10 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 23: ...alling a second switch module enables a redundant path and a separate Fibre Channel connection from the blade server to the external Fibre Channel network and SAN The Fibre Channel expansion card has two 2 or 4 Gbps Fibre Channel ports At least one switch module is required when you install a Fibre Channel expansion card in the blade server Important v When the switch module is installed in a Blad...

Page 24: ...nent on the switch module blade server or BladeCenter unit indicates that the component can be hot swapped which means that if the BladeCenter unit and operating system support hot swap capability you can remove or install the component while the BladeCenter unit is running Orange can also indicate touch points on hot swap components See the instructions for removing or installing a specific hot s...

Page 25: ...tive devices in their static protective packages until you are ready to install them To reduce the possibility of electrostatic discharge observe the following precautions v Limit your movement Movement can cause static electricity to build up around you v Handle the device carefully holding it by its edges or its frame v Do not touch solder joints pins or exposed printed circuitry v Do not leave ...

Page 26: ... documentation for the BladeCenter unit for instructions for how to properly use the ESD connector Typical location of ESD connector front of unit ESD connector CMM 1 CMM 2 ESD ESD Typical location of ESD connector rear of unit ESD connector TOP D TOP D BTM E BTM E 2 4 1 3 CRT MJR MNR 2 Alarms 1 14 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 27: ...east 2 seconds 3 Remove the acoustic attenuation module option if one is installed from the rear of the BladeCenter unit For more information see the documentation that came with the BladeCenter unit 4 Select only I O module bay 3 or bay 4 in which to install the switch module Note For details about I O module bay requirements and bay locations see the documentation for the BladeCenter unit and bl...

Page 28: ...he switch module takes approximately 60 seconds to complete the POST When the switch module is turned on an LED test occurs All LEDs are lit and remain lit for approximately 5 seconds then all the LEDs except the OK LED turn off The power LED flashes to indicate a normal POST condition then POST proceeds as described in the next step b To maintain proper airflow make sure that the ventilation area...

Page 29: ...ion that comes with the connected Fibre Channel device for information about installation configuration and startup sequence 14 Replace the acoustic attenuation module if you removed it in step 3 on page 15 15 Make sure that the ports on the switch module are enabled click I O Module Tasks Management Advanced Management Advanced Setup in the management module Web based interface Removing or replac...

Page 30: ... you placed another switch module into the bay and if you are using the external switch module ports insert any SFP modules that you removed in step 4 on page 17 into external Fibre Channel port 0 and Fibre Channel ports 15 through 19 For SFP module installation instructions see the documentation that comes with the SFP module 9 Use LC LC or LC SC fiber optic cables to connect the switch module ex...

Page 31: ...ocument might differ slightly from your hardware Information panel The front panel of the switch module contains information LEDs and six Fibre Channel ports as shown in the following illustration Port 0 Port 15 Port 16 Port 17 Port 18 Port 19 Port 0 LEDs Port 15 LEDs Port 16 LEDs Port 17 LEDs Port 18 LEDs Port 19 LEDs 0 19 SPD TX RX SPD TX RX SPD TX RX SPD TX RX SPD TX RX SPD TX RX 18 17 16 15 4G...

Page 32: ...f the Fibre Channel switch module has multiple sets of LEDs The LEDs in the first row at the top of the switch module represent the switch module status The remaining sets of LEDs represent status for the external Fibre Channel ports The port LEDs include port speed port status and port diagnostics The following illustration shows the locations of these LEDs on the switch module A description of e...

Page 33: ... 1 or later Any errors that are detected during POST are written to the system log This log is accessible through the errShow command For information about this command see the Fabric OS Administrator s Guide For information about error messages see the Fabric OS System Error Message Reference Manual Note You can also use the management module to make sure that the switch module is operating corre...

Page 34: ... Port speed LED This green LED is the topmost LED of the three LEDs v When this LED is green and steady the indicated port is operating at 4 Gbps v When this LED is not lit the indicated port is operating at 1 Gbps or 2 Gb Port status LED This green LED is in the middle of the three LEDs v When this LED is green and steady the indicated port is online v When this LED is green and flickering the in...

Page 35: ... beaconing is on v When this LED is amber and flashing rapidly it indicates the port diagnostics program has detected an error port fault v When this LED is not lit it indicates that there are no faults on the indicated port Chapter 3 Information panel LEDs and external Fibre Channel ports 23 ...

Page 36: ...24 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 37: ... connected to an external BladeCenter unit management module Ethernet port To enable the configuration settings in the management module Web interface click I O Module Tasks Admin Power Restart Important Before configuring the switch module make sure that the management modules in the BladeCenter unit are correctly configured In addition to access and manage the switch module from an external envi...

Page 38: ...wser in the address bar type http xxx xxx xxx xxx where xxx xxx xxx xxx is the IP address of the BladeCenter unit management module interface Note The default IP address for the BladeCenter unit management module is 192 168 70 125 2 Click GO or press Enter The Enter Network Password window opens 3 In the User Name field type the initial default user name USERID In the Password field type the initi...

Page 39: ... module IBM Support CD Establishing a Telnet session in a command line window You can access the switch module through IP enabled devices that are connected to the BladeCenter unit management module An Ethernet connection to the management module external ports on the BladeCenter unit is required For more information see the following documents v Installation and User s Guide for the BladeCenter u...

Page 40: ...er name and password are case sensitive 5 If you are accessing the switch module for the first time press Enter to change the switch passwords You are prompted for a password for the root factory and user accounts A Telnet password change window opens After you have changed all of the passwords the command prompt is displayed in the Telnet window 28 Brocade 4 Gb SAN Switch Module Installation Guid...

Page 41: ...unit management module Web interface v Through a Web browser on a network management workstation For you to configure the switch module through the Web interface the IP address and subnet masks must be compatible and the following configuration settings in the management module must be enabled v Switch module external ports v External management for external port To access a switch module from a n...

Page 42: ...ection contact your system or network administrator Establishing a Web interface session through the management module To establish a Web interface session through the BladeCenter unit management module complete the following steps 1 In your browser in the address field type http xxx xxx xxx xxx where xxx xxx xxx xxx is the IP address of the BladeCenter unit management module interface Note The de...

Page 43: ...nd click Start Web Session The I O module Advanced Web Tools interface window opens 10 To perform switch module administrative tasks click Admin and log in to the switch In the User Name field type the initial default user name USERID In the Password field type the initial default password PASSW0RD the sixth character is a zero not the letter O The user name and password are case sensitive For mor...

Page 44: ...er unit v BladeCenter Management Module User s Guide v BladeCenter Management Module Installation Guide for the BladeCenter unit To establish a Web interface session through a Web browser complete the following steps 1 Open a Web browser on the network management workstation 2 Type one of the following Web addresses in the address field These Web addresses contain default IP addresses For I O bay ...

Page 45: ...ssword field type the initial default password PASSW0RD the sixth character is a zero not the letter O The user name and password are case sensitive For more information about using the Advanced Web Tools interface see the Web Tools Administrator s Guide version 5 0 1 or later Chapter 5 Configuring the switch module through the Advanced Web Tools interface 33 ...

Page 46: ...34 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 47: ... comparisons v Enables performance tuning of the Brocade 4 Gb SAN Brocade ISL Trunking for IBM Eserver BladeCenter v Logically combines the external switch module ports into two 12 Gb trunk links when the ports are connected inter switch linked to another Brocade switch module v Ensures optimum performance for servers that use this trunk Brocade Performance Bundle for IBM Eserver BladeCenter Inclu...

Page 48: ... To purchase and obtain a license key for an optional feature go to http www ibm com servers eserver bladecenter or call IBM In the U S and Canada call 1 800 IBM SERV 1 800 426 7378 For all other countries see http www ibm com planetwide for support telephone numbers A license key will be provided through the Web site that is described in the documentation that you receive after you purchase the f...

Page 49: ...Brocade Fabric OS Command Reference Manual To make sure that the license has been successfully added to the switch key run the licenseshow command For information about this command see the Brocade Fabric OS Command Reference Manual Chapter 6 Optional features of the Brocade 4 Gb SAN switch modules 37 ...

Page 50: ...38 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 51: ...in the Hardware Maintenance Manual and Troubleshooting Guide or Problem Determination and Service Guide on the IBM Documentation CD that comes with the system Note For some IntelliStation models the Hardware Maintenance Manual and Troubleshooting Guide is available only from the IBM support Web site v Go to the IBM support Web site at http www ibm com support to check for technical information hin...

Page 52: ...i cgi Getting help and information from the World Wide Web On the World Wide Web the IBM Web site has up to date information about IBM Eserver and IntelliStation systems optional devices services and support The address for the IBM xSeries and the BladeCenter information is http www ibm com eserver xseries The address for IBM IntelliStation information is http www ibm com intellistation You can fi...

Page 53: ...rranty service See http www ibm com planetwide for support telephone numbers or in the U S and Canada call 1 800 IBM SERV 1 800 426 7378 In the U S and Canada hardware service and support is available 24 hours a day 7 days a week In the U K these services are available Monday through Friday from 9 a m to 6 p m Appendix A Getting help and technical assistance 41 ...

Page 54: ...42 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 55: ...Machines you purchase for your use and not for resale The term Machine means an IBM machine its features conversions upgrades elements or accessories or any combination of them The term Machine does not include any software programs whether pre loaded with the Machine installed subsequently or otherwise Nothing in this Statement of Limited Warranty affects any statutory rights of consumers that ca...

Page 56: ...or capability other than that authorized by IBM in writing accident modification unsuitable physical or operating environment or improper maintenance by you v failure caused by a product for which IBM is not responsible and v any non IBM products including those that IBM may procure and provide with or integrate into an IBM Machine at your request The warranty is voided by removal or alteration of...

Page 57: ...ved over the telephone or electronically through your application of Machine Code or software updates or with a CRU IBM or your reseller if approved by IBM to provide warranty service will either at its discretion 1 repair it to make it function as warranted or 2 replace it with one that is at least functionally equivalent If IBM is unable to do either you may return the Machine to your place of p...

Page 58: ...with any laws applicable to such Personal Data Limitation of Liability IBM is responsible for loss of or damage to your Machine only while it is 1 in IBM s possession or 2 in transit in those cases where IBM is responsible for the transportation charges Neither IBM nor your reseller are responsible for any of your confidential proprietary or personal information contained in a Machine which you re...

Page 59: ...W LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU Governing Law Both you and IBM consent to the application of the laws of the country in which you acquired the Machine to govern interpret and enforce all of your and IBM s rights duties and obligations arising from or relating in any manner to the subject matter of this Statement of Limited Warranty without regard to co...

Page 60: ...ivil Courts of Justice of Santiago COLOMBIA Jurisdiction The following is added after the first sentence Any litigation arising from this Statement of Limited Warranty will be settled exclusively by the Judges of the Republic of Colombia EQUADOR Jurisdiction The following is added after the first sentence Any litigation arising from this Statement of Limited Warranty will be settled exclusively by...

Page 61: ...t s Jurisdiction VENEZUELA Jurisdiction The following is added after the first sentence Any litigation arising from this Statement of Limited Warranty will be settled exclusively by the Courts of the Metropolitan Area Of the City of Caracas NORTH AMERICA How to Obtain Warranty Service The following is added to this Section To obtain warranty service from IBM in Canada or the United States call 1 8...

Page 62: ...g Law The following replaces laws of the country in which you acquired the Machine in the first sentence laws of the State or Territory CAMBODIA AND LAOS Governing Law The following replaces laws of the country in which you acquired the Machine in the first sentence laws of the State of New York United States of America CAMBODIA INDONESIA AND LAOS Arbitration The following is added under this head...

Page 63: ...2 as to any other actual damage arising in any situation involving nonperformance by IBM pursuant to or in any way related to the subject of this Statement of Limited Warranty the charge paid by you for the individual Machine that is the subject of the claim For purposes of this item the term Machine includes Machine Code and Licensed Internal Code LIC Arbitration The following is added under this...

Page 64: ...s The following paragraph is added to this section The warranties specified in this section are in addition to any rights you may have under the Consumer Guarantees Act 1993 or other legislation which cannot be excluded or limited The Consumer Guarantees Act 1993 will not apply in respect of any goods which IBM provides if you require the goods for the purposes of a business as defined in that Act...

Page 65: ... by the respective nominating party Proceedings shall continue from the stage they were at when the vacancy occurred If one of the parties refuses or otherwise fails to appoint an arbitrator within 30 days of the date the other party appoints its the first appointed arbitrator shall be the sole arbitrator provided that the arbitrator was validly and properly appointed All proceedings shall be cond...

Page 66: ...rm warranty service or 2 from IBM If you purchase a Machine in a Middle Eastern or African country you may obtain warranty service for that Machine from the IBM entity within the country of purchase if that IBM entity provides warranty service in that country or from an IBM reseller approved by IBM to perform warranty service on that Machine in that country Warranty service in Africa is available ...

Page 67: ...e Algeria Benin Burkina Faso Cameroon Cape Verde Central African Republic Chad Comoros Congo Republic Djibouti Democratic Republic of Congo Equatorial Guinea French Guiana French Polynesia Gabon Gambia Guinea Guinea Bissau Ivory Coast Lebanon Madagascar Mali Mauritania Mauritius Mayotte Morocco New Caledonia Niger Reunion Senegal Seychelles Togo Tunisia Vanuatu and Wallis Futuna all disputes arisi...

Page 68: ...e Code IBM may however institute proceedings in a competent court in the country of installation In Estonia Latvia and Lithuania all disputes arising in connection with this Statement of Limited Warranty will be finally settled in arbitration that will be held in Helsinki Finland in accordance with the arbitration laws of Finland then in effect Each party will appoint one arbitrator The arbitrator...

Page 69: ... apply to damages for bodily injuries including death and damages to real property and tangible personal property for which IBM is legally liable 2 UNDER NO CIRCUMSTANCES IS IBM ITS SUPPLIERS OR RESELLERS LIABLE FOR ANY OF THE FOLLOWING EVEN IF INFORMED OF THEIR POSSIBILITY 1 LOSS OF OR DAMAGE TO DATA 2 INCIDENTAL OR INDIRECT DAMAGES OR FOR ANY ECONOMIC CONSEQUENTIAL DAMAGES 3 LOST PROFITS EVEN IF...

Page 70: ...the functionality of the Machine for its normal use and the Machine s conformity to its Specifications The following paragraphs are added to this section The limitation period for consumers in action for breach of warranty is the statutory period as a minimum In case IBM or your reseller is unable to repair an IBM Machine you can alternatively ask for a partial refund as far as justified by the re...

Page 71: ... items 1 and 2 unchanged GERMANY What this Warranty Covers The following replaces the first sentence of the first paragraph of this section The warranty for an IBM Machine covers the functionality of the Machine for its normal use and the Machine s conformity to its Specifications The following paragraphs are added to this section The minimum warranty period for Machines is twelve months In case I...

Page 72: ...hat this Warranty Covers The following is added to this section Except as expressly provided in these terms and conditions all statutory conditions including all warranties implied but without prejudice to the generality of the foregoing all warranties implied by the Sale of Goods Act 1893 or the Sale of Goods and Supply of Services Act 1980 are hereby excluded Limitation of Liability The followin...

Page 73: ...VAKIA Limitation of Liability The following is added to the end of the last paragraph The limitations apply to the extent they are not prohibited under 373 386 of the Slovak Commercial Code SOUTH AFRICA NAMIBIA BOTSWANA LESOTHO AND SWAZILAND Limitation of Liability The following is added to this section IBM s entire liability to you for actual damages arising in all situations involving nonperform...

Page 74: ... limits also apply to IBM s suppliers and resellers They state the maximum for which IBM and such suppliers and resellers are collectively responsible Items for Which IBM is Not Liable Save with respect to any liability referred to in item 1 above under no circumstances is IBM or any of its suppliers or resellers liable for any of the following even if IBM or they were informed of the possibility ...

Page 75: ...tative or your reseller for country and location specific information 1 Customer Replaceable Unit CRU Service IBM provides replacement CRUs to you for you to install CRU information and replacement instructions are shipped with your Machine and are available from IBM at any time on your request Installation of Tier 1 CRUs is your responsibility If IBM installs a Tier 1 CRU at your request you will...

Page 76: ...vice is a combination of Type 1 and Type 3 see above 7 CRU and Customer Carry In or Mail In Service This type of Warranty Service is a combination of Type 1 and Type 4 see above When a 5 6 or 7 type of warranty service is listed IBM will determine which type of warranty service is appropriate for the repair This type of service is called ThinkPad EasyServ or EasyServ in some countries The IBM Mach...

Page 77: ... 4175 Denmark 45 4520 8200 Netherlands 31 20 514 5770 Estonia 386 61 1796 699 Poland 48 22 878 6999 Finland 358 8001 4260 Portugal 351 21 892 7147 France 33 238 557 450 Slovakia 421 2 4954 1217 Germany 49 1805 253553 Slovenia 386 1 4796 699 Greece 30 210 680 1700 Spain 34 91 714 7983 Hungary 36 1 382 5720 Sweden 46 8 477 4420 Ireland 353 1 815 4000 United Kingdom 44 0870 550 0900 Italy 39 800 820 ...

Page 78: ...66 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 79: ...NY 10504 1785 U S A INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not...

Page 80: ...kill ThinkPad EtherJet Tivoli e business logo Tivoli Enterprise Eserver Update Connector FlashCopy Wake on LAN IBM XA 32 IBM logo XA 64 IntelliStation X Architecture NetBAY XceL4 Netfinity XpandOnDemand NetView xSeries OS 2 WARP Intel MMX and Pentium are trademarks of Intel Corporation in the United States other countries or both Microsoft Windows and Windows NT are trademarks of Microsoft Corpora...

Page 81: ...ng to processor storage real and virtual storage or channel volume KB stands for approximately 1000 bytes MB stands for approximately 1 000 000 bytes and GB stands for approximately 1 000 000 000 bytes When referring to hard disk drive capacity or communications volume MB stands for 1 000 000 bytes and GB stands for 1 000 000 000 bytes Total user accessible capacity may vary depending on operating...

Page 82: ...quipment owners in recycling their IT products Information on IBM product recycling offerings can be found on IBM s Internet site at http www ibm com ibm environment products prp shtml Notice This mark applies only to countries within the European Union EU and Norway This appliance is labeled in accordance with European Directive 2002 96 EC concerning waste electrical and electronic equipment WEEE...

Page 83: ...ual for specific battery information The battery must be recycled or disposed of properly Recycling facilities may not be available in your area For information on disposal of batteries outside the United States go to http www ibm com ibm environment products batteryrecycle shtml or contact your local waste disposal facility In the United States IBM has established a return process for reuse recyc...

Page 84: ... by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may caus...

Page 85: ...on IBM option cards This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment Attention This is a Class A product In a...

Page 86: ...Japanese Voluntary Control Council for Interference VCCI statement 74 Brocade 4 Gb SAN Switch Module Installation Guide ...

Page 87: ......

Page 88: ... Part Number 24R9711 Printed in USA 1P P N 24R9711 ...