background image

1

Dear Client

Thank you for Purchasing our

XP-1A Handheld SF6 Gas

Leak Detector

. Please read the manual in detail prior to first use,

which will help you use the equipment skillfully.

Our aim is to improve and perfect the

company's products continually, so there may be

slight differences between your purchase equipment

and its instruction manual. You can find the changes

in the appendix. Sorry for the inconvenience. If you have further

questions, welcome to contact with our service department.

The input/output terminals and the test column

may bring voltage, when you plug/draw the test wire or

power outlet, they will cause electric spark. PLEASE

CAUTION RISK OF ELECTRICAL SHOCK!

Company Address:

T4

No. 41, High-tech 2 Road

East Lake High-tech Development Zone

Wuhan

Sales Hotline: 86-27- 87457960

After Service Hotline

:

86-27- 87459656

Fax: 86-27- 87803129

E-mail: [email protected]

Website: www.hvtest.cc

Summary of Contents for XP-1A

Page 1: ... You can find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column may bring voltage when you plug draw the test wire or power outlet they will cause electric spark PLEASE CAUTION RISK OF ELECTRICAL SHOCK Company Address T4 No 41 High tech 2 Road East Lake High tech Develo...

Page 2: ... and prevent the product or other relevant subassembly to damage In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out maintenance or repair work To avoid fire and personal injury Use Proper Power Cord Only use the power wire supplied by the product or meet the specification of this produce Connect and Disconnect Correct...

Page 3: ...ad the instruction manual to acquire information about the ratings Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type and rating specified for the product Avoid Touching Bare Circuit and Charged Metal Do not touch the bare connection points and parts of energized equipment Do Not Operate with Suspicious Failures If yo...

Page 4: ... Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not taken ...

Page 5: ...t I Overview 6 II Features 6 III Instrument composition 7 IV Preparation 7 V Operation instruction 8 VI Leakage preparation 10 VII Precautions 10 VIII Application 11 IX Maintenance 11 X Technical parameters 12 ...

Page 6: ...ht emitting diode in a progressive manner indicated a wide range of degree of leakage It is also used to display the sensitivity level and battery touch keyboard all operations avant garde slim type design greatly facilitates the user to use and maintain Before using the equipment must read this manual carefully After reading this manual if you have any questions or suggestions please feel free to...

Page 7: ...III Instrument composition 1 Probe 2 Probe guards 3 Power switch 4 Battery test 5 Reset 6 Audio gradient 7 Sensitivity increase 8 Sensitivity reduce 9 LED indication 10 Flexible probe IV Preparation Battery install As shown remove battery cover at the bottom of the product insert the battery the negative electrode outward toward the direction of the battery compartment cover See figure 2 ...

Page 8: ...color light emitting diodes indicates the actual battery voltage See figure 4 If you press and hold the Battery Test button display the battery voltage Release the battery test button to return to the normal state 2 Automatic circuit Reset function The instrument has an automatic circuit and a reset button the instrument can ignore environmental levels of refrigerant Automatic circuit when you tur...

Page 9: ...sitivity is indicated by LEDs Beep may indicate the frequency difference sensitivity When turned on the instrument automatically identified as the 5th gear Press the key to increase reduce sensitivity key you can adjust the sensitivity When you press the button to adjust the light emitting diode display in red Each increase or decrease indicate the relative sensitivity change doubled which makes t...

Page 10: ...tivity adjustment key 4 When gas leak is found beep will be rapid the arc tube will also change according to changes in the way light emission concentration 5 Spiritual sensitivity can be adjusted at any time when in operation and does not affect the test 6 As before the leak source is located has the highest warning red light emitting diode 1 Green 6 Should reset button reset to zero reference le...

Page 11: ...ted to CFCS e g R12 R11 R500 R503etc HCFCs e g R22 R123 R124 R502etc HFCs e g R134a R404a R125etc Other mixtures may also be detected such as the AZ 50 HP 62 MP39etc 2 Hospital disinfection equipment has detected ethylene oxide leak detected carrying the halogen gas 3 Detect SF6 of high voltage circuit breaker 4 Detecting most of chlorine fluorine and bromine gas halogen gas 5 Detection equipment ...

Page 12: ... probe life is directly related to conditions and frequency of use therefore difficult to forecast the exact replacement time When an alarm or instability in the clean pure air the probe should be replaced Replace probe steps 1 Confirm that the product is turned off 2 Counterclockwise unscrew the old probe 3 Clockwise install the alternate probe in the accessory case X Technical parameters 1 Power...

Page 13: ...13 10 Warm up time about 2s 11 Weight 560 g 12 Dimension 22 9 6 5 6 5cm 13 Length of probe rod 35 5cm ...