BX444 Gas Detector

Detects Carbon Monoxide,Natural Gas & L.P.G.

230V and 12V DC.

One, two, three or four Zone.

Self Diagnostic

Manual or Automatic Reset

Adjustable Pre-Alarm

Catalytic and Electrochemical Sensors

Audible Alarm

Sensor Fault Alarm

Manual Test Function

144 x 144 DIN Enclosure

Panel or wall Mounting

1 Year Guarantee

Duomo is recognised within the Gas industry for
providing a comprehensive range of low cost, high
reliability gas detection for many applications. We
have installed and commissioned Natural gas and
carbon monoxide sensors in applications such as
boiler rooms, kitchens, car parks, aircraft hangars,
factories and shopping centres.

Application

The BX444 has been designed to meet all European
Normative proposals for the detection of Natural Gas,
LPG and Carbon Monoxide Gas Detectors. The BX444
is provides protection from gas leakage in areas such
as Boiler Rooms Roof spaces unventilated voids. Car-
bon Monoxide is an invisible, odourless gas which in-
hibits the bodies ability to process Oxygen. The BX444
protects against this in underground or poorly venti-
lated car parks, boiler rooms, vehicle servicing areas
etc. Remote sensors are installed in the areas which
require connected to remote sensors located in the pro-
tected area. The 144 x 144 enclosure is wall or panel
mounting.

Operation

If the remote sensors sense the presence of Gas the
detector operates a pre-alarm relay - used for remote
sirens or extract fans; if the level of gas continues to
rise then the main alarm relay is activated to, either in
the case of explosive gases,  break the electrical sup-
ply to the Safety Shut Off Valve or for CO sound a Gen-
eral Alarm to allow  evacuation of the area.

Features

The  Pre-Alarm can be adjusted,  in the case of Natu-
ral Gas or LPG, from 8%  to 15% of the Lower Ex-
plosive Level (LEL).  For Carbon Monoxide,  it can
be adjusted from 120ppm to 250ppm. The Main
Alarm thresholds are not adjustable and are fixed at
20% LEL for explosive gas and 300 ppm  for Car-
bon Monoxide. The detectors can be set for either
toxic or explosive Gas. Or both.

It is possible to set  one zone for explosive gas such
as  Natural Gas or LPG and another for toxic gas for
example Carbon Monoxide. An LED display on the
fascia indicates the levels of detected gas in either:-
parts per million (ppm) or percentage of Lower Ex-
plosive Level (%LEL). Lights above the display indi-
cate which sensor the Numeric LED display refers
to. It is possible to use the detector as a one, two,
three or four zone by enabling or disabling each
channel.

A ‘TEST’ button on the facia, when pressed, checks
the complete function of the BX444 and sensors. A
permanent  diagnostic check is made of sensor func-
tion. If any sensors should become faulty or be  con-
nected incorrectly the ‘FAULT’ light will illuminate
and the detector will fail safe.

CAUTION!

Carefully read the following instructions prior to installation of this device. Always
keep this pamphlet for future reference. Ensure that the gas detection system is
wired correctly, the appropriate sensor is installed and used only for the purpose
which it is intended.

BX444 Four Zone

Gas Detector

Summary of Contents for BX444

Page 1: ...el of gas continues to rise then the main alarm relay is activated to either in the case of explosive gases break the electrical sup ply to the Safety Shut Off Valve or for CO sound a Gen eral Alarm to allow evacuation of the area Features The Pre Alarm can be adjusted in the case of Natu ral Gas or LPG from 8 to 15 of the Lower Ex plosive Level LEL For Carbon Monoxide it can be adjusted from 120p...

Page 2: ...ess to reset alarm This resets the detector memory 11 TEST Push button Provides full function test of detector 12 FAULT Flashes when the sensor is either faulty connected incorrectly or not selected 13 OVERLOAD Power consumption of the BX444 is too high 14 TOXIC Indicates that the Carbon Monoxide function is selected BX444 Facia 6 7 8 9 10 11 12 13 14 1 2 3 4 5 Digital Display This shows the quant...

Page 3: ...es above the room ambient may be experienced It is if possible better to mount the sensors on the opposite wall This is of course dependant on the size of the protected area Natural Gas is lighter than air and therefore will obviously rise therefore the SG590 methane sensor should be mounted 300mm from the ceiling of the protected area For LPG Propane and butane the SG590 LPG must be connected LPG...

Page 4: ... cables are routed through conduit or trunking containing other wiring the use of screened cable is advisable The wiring should be performed by a qualified person in accordance with current regulations Fig 4 Cable Entry Points The plug in terminal rail makes installation easy and quick Note It is essential that enough length is left in the cable loom to allow the facia to be hinged open as shown i...

Page 5: ... ON position and switch 1 to the off position In the above picture this shows zone 1 Toxic zone 2 explosive zone 3 toxic zone 4 explosive Pre Alarm Sensitivity Adjustment The Pre Alarm can be adjusted in the case of Natural Gas or LPG from 8 to 15 of the Lower Explosive Level LEL For Carbon Monoxide it can be adjusted from 120ppm to 250ppm Adjustment is made using the pre alarm potentiometer marke...

Page 6: ...of this gas detector Duomo will not be held responsible or liable This Gas detector is a safety device and therefore should only be maintained and installed by qualified persons To ensure correct function after installation Duomo provide a commissioning service using cali brated test gases For the service call 01905 797989 Warning To make the main alarm a latching operation move switch 1 shown to ...

Page 7: ...modes i Auto reset ii Latch with manual Reset When you have selected the correct memory function you must press the reset button so that this change takes effect The main alarm relay changes over the volt free relay and then with the Main Alarm light still on the relay re energises Check the position of the Jumper link JP1 This is located between the two terminal plugs When in the C position the r...

Page 8: ...upply 4 20mA output CO200 and 230 Catalytic Carbon Monoxide Gas Sensor with digital display and Change over Relay 30ppm CO IP55 Product Overview Gas Detection CO200A CO Sensor for Car Parks 12 or 24VDC supply 4 20mA Output IP55 Gas Safestart Guarantee This device is guaranteed for a period of 12 months from the date of purchase Conditions Substitution free of charge of any component recognized as ...