background image

    Belonging   to

CONFORMITY

Installation and user
guide

Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.

Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and
keep it for future reference. It is also recommended to perform the electrical connections correctly as
per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side

EN 50270

Compliant  EN 60079-29-1

Installation  EN 60079-29-2

Reports issued by  TUV Italia

Channel:  Beinat  gas  solutions

Electric connections also available on

Conventional Gas Sensor SGM595/A

                                                                     V. R1bd1

The SGM595/A  is born  from  the elegance and  prestige  that  has  always  distinguished  BEINAT S.r.l. and  from
the  home  fitness  concept.
The   probe  is  a  Catalytic gas  detection  unit  with IP66 protection  that, together  with one  of  BE  INAT’s industrial
type  Control  Units,  detects  the  presence  of  esplosive  gas  such  as  Methane,  LPG,  Hydrogen,  and  other  types
of  gas.
The probe is managed by a  microprocessor which not only supplies an alarm signal to the control  unit connected
to  it,  but    also  allows  execution  of  a  self-diagnosis  and  therefore  an  AUTOMATIC    CALIBRATION,

 

in  order  to

always  have  the  maximum  detection  accuracy.
The  self-calibration  means  the  probe  adapts  in  harsh  and  variable  temperature  environments,  avoiding  false
alarms  due  to  anomalous  events.
The probe has a 0 ÷ 20 % LEL linear output conforming to the 4 ÷ 20mA standard, for which can be connected
with  one  of  BEINAT's  industrial  control  units.
The  important  innovation  of  this  probe  is:
The possibility to substitute the sensor at the end of the operating cycle or fault by the technician without having
to  send  to  BEINAT  Srl.

Indispensabile  instrument  for  the  annual  check  of  the  probes
Instrument  of  testing  TS1008
To  facilitate  the  reading  of  the  functional  parameters  of  the  probe  as  well  as  the  control  of  annual
operating,  the  BEINAT  S.r.l.  has  built  a  new  portable  tester  TS1008.
The  tester  allows  to  read  all  the  data  in  the  memory  of  the  probes  eand  by  serial  transmission,  it
prints  the  ticket  that  confirms  the  testing  data.

Summary of Contents for SGM595/A

Page 1: ...rotection that together with one of BE INAT s industrial type Control Units detects the presence of esplosive gas such as Methane LPG Hydrogen and other types of gas The probe is managed by a microprocessor which not only supplies an alarm signal to the control unit connected to it but also allows execution of a self diagnosis and therefore an AUTOMATIC CALIBRATION in order to always have the maxi...

Page 2: ...TATIONS The installation of the SGM595 A Sensor its ordinary and extraordinary maintenance every six months and its out of service removal at the end of the functional life guaranteed by the manufacturer must be carried out by authorized or specialized personnel Do not allow it to become wet The control unit can be seriously damaged as it is not waterproof either when immersed in water or exposed ...

Page 3: ...ed personnel Side View 60 mm 80 mm 80 mm Rearward View Foro 6 5 mm 100 mm 100 mm 40 mm Front View CONTROLUNITS MOUNTING PROBES Max DEGREE PRE ALARMS POSITIVE OPERATING protec alarms safety range GS100M unit 1 zone Wall cabinet 1 I P 4 4 2 1 Y E S N O GS300M unit 1 zone Wall cabinet 3 I P 4 4 2 1 Y E S N O GS300 Mc unit 1 zone Wall cabinet 3 I P 4 4 2 1 Y E S N O BX444 MC unit 1 zone Wall cabinet 4...

Page 4: ...ow The probe detects an anomaly FAULT 1 2 3 4 5 6 C NO C NO C NO Fault Relay Pre Allarme Relay Main Alarm Relay Optional Relay Board CARD03 Linear Output 4 20 mA 100 20 100 20 SELECTION OF THE OPERATING RANGE The Conventional Probes NOT SUITABLE IN ATEX ZONE LEAVE THE FACTORY WITH A DEFAULT OPERATING RANGE VALUE SET AT 20 OF THE LEL To select the operation range to 100 LEL you need to move the jum...

Page 5: ...irectly WARNING These measurement should be performed in clean air Moreover this test must be performed only with the probe connected to a control unit or with a 220 Ohm resistance installed between terminal 2 and terminal 3 Linear Otput 4 20 mA 3 2 1 R 0 1 3 2 1 1 VDC Voltmeter Power Supply 12 24 V Troubleshooting before calling a technician Display legend Displays the type of probe or device Dis...

Page 6: ... controlled boiler burner industrial kitchens etc but on the opposite side 2 The probes must not be affected by fumes vapors and by sources of moving air which could distort the detection 3 The probes must not be installed near sources of heat fans or vacuum cleaners NOTE Recall that the GAS detection sensors placed inside the probe are perishable components whose average duration is variable 5 ye...

Page 7: ...e of gas presence cannot be found or removed abandon the building and call the emergency services when outside fire department distributors etc IMPORTANT The operation test should not be carried out with the gas tap as this does not guarantee a sufficient concentration to activate the general alarm Warning If you have the following symptoms vomiting sleepiness or else go to the closest first aid s...

Page 8: ...es points in case you buy a new and similar product local collection points waste collection center local recycling center etc By ensuring this product is disposed of correctly you will help prevent potential negative consequence for the environment and human health which could otherwise be caused by inappropriate waste handing of this product The recycling of materials will help to conserve natur...