background image

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0457239A

Note:  

Changed items have been underlined.

Merchandisers

®

C

B

D

A

C

D

P2EP

LUS

Data Sheet Set

P/N 0457239A

NSF

®

Certified

March  2005

Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

6W

Fan Assembly

(1)

0058698

Fan Motor, Evaporator

0142780

Fan Blade
embossing toward motor

B.

0137880

Optional Adjustable 

(2)

Refrigeration Thermostat

Item

Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

C.

0428648

Ballast 2 lamps

(3)

0428649

Ballast 3 lamps

(3)

D.

Fluorescent Lamp

(4)

Replace with like fixtures

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Summary of Contents for P2EP

Page 1: ...80 Fan Blade embossing toward motor B 0137880 Optional Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS C 0428648 Ballast 2 lamps 3 0428649 Ballast 3 lamps 3 D Fluorescent Lamp 4 Replace with like fixtures We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle th...

Page 2: ... 40 5 8 1032 Distance between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of case to center of knoc...

Page 3: ...ONE Defrost Water lb ft day 6 15 based on case configuration and product loading OFFTIME P2EPLUS Time minutes NONE ELECTRIC OR GAS Not Recommended CONVENTIONALCONTROLS Low Pressure Backup Control P2EPLUS CI CO 27 F 17 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Liquid Line in 3 8 S...

Page 4: ...t 120V 60Hz 0 52 0 78 36 54 Export 230V 50Hz 0 56 0 84 88 132 Constant on Anti sweat Heaters NA Cycling Anti sweat Heaters NA Min Circuit Ampacity With Standard Fans 120V 60Hz 1 20 1 70 Export 230V 50Hz 0 76 1 04 With Energy Efficient Fans 120V 60Hz 0 72 0 98 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost...

Page 5: ...k W White 120V POWER 120V NEUTRAL FIELD GROUND CASE GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light...

Page 6: ...L Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 3 R 4 4 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 3 4 4 120V NEUTRAL ORANGE OR TAN BAND Light Switch 120V POWER ORANGE OR TAN BAND B ...