background image

/Chino

RCD

DR

OP IN REFRIGERA

TED SELF SER

VICE

REV

.0105

Installation

& Operation

Manual

RCD

DROP IN REFRIGERATED SELF SERVICE

P/N IGSS-RCD-0105

INSTALLATION & OPERATION GUIDE

Summary of Contents for Chino RCD

Page 1: ...Chino RCD DROP IN REFRIGERATED SELF SERVICE REV 0105 Installation Operation Manual RCD DROP IN REFRIGERATED SELF SERVICE P N IGSS RCD 0105 INSTALLATION OPERATION GUIDE...

Page 2: ...or any possible shortages of material If a shortage should exist and is found to be the responsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrie...

Page 3: ...1 4 19 1 2 14 1 4 9 Fan 46 43 11 2 11 2 18 1 2 5 1 4 25 RCD 25 Shown with light 25 depth and 9 height options 20 1 2 6 7 8 RCD Remote Shown with Options Scale 3 4 Optional Light Optional Step 38 3 8 2...

Page 4: ...sArmstrong sArmaflex b Where condensate drains are located in dead air spaces between refrigerators or between a refrigerator and a wall provide means to prevent freezing The water seal should be insu...

Page 5: ...from left end of case Remove product racks Remove refrigeration and drain access panels labeled TX valve mechanical only and drain are located under each access panel at end of the case ELECTRONIC Th...

Page 6: ...e top The switch controlling the lights the plug provided for digital scale and the thermometer are located at the rear of the case mullion FIELD WIRING SERIAL PLATE AMPERAGE Field Wiring must be size...

Page 7: ...ting will cause serious product loss Discoloration dehydration and spoilage can be controlled with proper use of the equipment and handling of product Product temperature should always be maintained a...

Page 8: ...F U R R TIPS TROUBLESHOOTING Before calling for service check the following 1 Check electrical power supply to the equipment for connection 2 Check fixture loading Overstocking case will affect its pr...

Page 9: ...125 18 36 30 125 35 Forced 4 1 2 Axial 40 3 1 44 Air 8 3 16 Deep 4 175 18 36 30 125 35 Forced 4 1 2 Axial 40 3 54 Air 3 3 6 175 18 36 30 125 35 Forced 4 1 2 Axial 40 3 72 Air 4 3 8 175 18 36 30 125 35...

Page 10: ...elf Contained w Ref Rear Storage 120V 15 0 MCA 60Hz Front Display Evaporator 2 4 Axial Fan 0000 1212 Note case must be grounded Ballast MagneTek B260i120RH F48T12 SPX30 M Cap red blue blue brown orang...

Page 11: ...Revisions No Description Checked By By RCD 5 220V Remote Case Wiring Diagram W1910005 Drop In Cold Sandwich Deli Display 220V 50Hz M Evaporator 4 Axial Fan 125 01 3142 220V 0 5A Anti Sweat Heating Tap...

Page 12: ...l temperature performance Coils should be properly fed with a refrigerant according to manufacturer s recommendations b Observation of outside influences such as drafts radiant heating from the ceilin...

Page 13: ...ns clear of dirt dust etc 19 Is there a shortage of refrigerant 20 Has the equipment been modified to use replacements for CFC 12 CFC 502 or other refrigerant If so have the modifications been made in...

Page 14: ...comes in contact with the tool or equipment i Make sure that all refrigeration equipment is installed and adjusted in strict accordance with Hussmann s recommendations j See that all storage and refr...

Page 15: ...der this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor...

Page 16: ...cular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of this publication may be obtained by contact i...

Reviews: