background image

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

B

E

C

F

E

F

A

F

D

P/N 0395955F

Merchandisers

®

Note: Changed items have been underlined.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

6W

Fan Assembly

(1)

0058698

Fan Motor, Evaporator 

0142780

Fan Blade
embossing toward motor

B. 0311588

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0137880

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

H

EATERS

D.

Canopy Anti-Sweat Heater

(4)

NA

4 ft

0109417

6 ft

0109417

8 ft

0109418

12 ft

L

AMPS AND

B

ALLASTS

E.

Ballast, Electronic

(5)

0376409

2 lamps

0376410

3 lamps

F.

Fluorescent Lamp

(6)

Replace with like fixtures

C2-LE

Technical Data Sheet

P/N  0395955F

NSF

®

Certified

February  2006

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Summary of Contents for C2-LE

Page 1: ...ion Thermostat Item Part Description Wiring Item HEATERS D Canopy Anti Sweat Heater 4 NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft LAMPS AND BALLASTS E Ballast Electronic 5 0376409 2 lamps 0376410...

Page 2: ...kout 38 1 4 972 64 3 8 1635 88 3 8 2245 136 1 2 3467 Back O S of case to center of knockout 34 5 8 881 34 5 8 881 34 5 8 881 34 5 8 881 Length of electrical raceway 16 1 8 410 34 1 2 876 35 5 8 903 35...

Page 3: ...rature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 3 6 ft 1 8...

Page 4: ...46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30...

Page 5: ...rounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connec...

Page 6: ...tch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 5 BL R R BL BL 5 6 6 6 6 6 6 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 5 6 6 R R 6 Grayed compone...

Page 7: ...f is placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 12 in 15 14 in or less 30 18 in or less 45 18 in or less...

Page 8: ...lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of top panel 2 Remove the one piece...

Reviews: